《BS EN 50411-2-9-2010 Fibre organisers and closures to be used in optical fibre communications systems - Product specifications - Non-sealed closures for air blown fibre microduct c.pdf》由会员分享,可在线阅读,更多相关《BS EN 50411-2-9-2010 Fibre organisers and closures to be used in optical fibre communications systems - Product specifications - Non-sealed closures for air blown fibre microduct c.pdf(44页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationFibre organisers and closures to be used in optical fibre communications systems Product specificationsPart 2-9: Non-sealed closures for air blown fibre microduct cable, for cate
2、gory S Environmental conditions and environmental tests for telecommunications equipment Construction: (I) Closures Duct and cable port entries and dimensions (all direct burial, jointing pit or aerial mounted) Closure Min. number of ports Maximum sizes of protected microduct cables or ducts (mm) Ma
3、ximum physical dimensions (mm) Length L Width W Depth D (T) Closures Inline retrofit ports Range of drop ports (I) 2 50 N/A 410 120 120 (Y) Closures (T) 3 50 50 390 240 100 (H) Closures (Y) 3 50 50 380 210 100 (H) 4 60 60 830 340 160 (U) Closures (U) 12 50 50 600 470 310 BS EN 50411-2-9:2010EN 50411
4、-2-9:2010 4 Contents 1 Scope . 7 1.1 Product definition . 7 1.2 Operating environment . 7 1.3 Test severity 7 1.4 Reliability . 7 1.5 Quality assurance 7 1.6 Allowed fibre and cable types . 7 1.7 Allowed microduct connector types . 7 1.8 Microduct storage constraints . 8 1.9 Essential differences be
5、tween sealed and non-sealed ABF closures 8 1.10 Closures configurations defined diagrammatically By shape and application . 8 2 Normative references 9 3 Terms, definitions and abbreviations . 10 3.1 Definitions 10 3.2 Abbreviations . 12 4 Description 12 4.1 Microduct closure . 12 4.2 Closure housing
6、 functions 13 4.3 Burst pressure 13 4.4 Closure housing configurations 13 4.5 Entry retention device or seal . 15 4.6 Common base configurations . 15 4.7 Microduct management system 15 4.8 Materials 16 4.9 Colour and marking 16 4.10 Microduct connectors applications and capacity . 16 5 Variants 17 6
7、 Dimensions 19 6.1 Dimensions of (I) inline closures . 19 6.2 Dimensions of (T) inline closures 20 6.3 Dimensions of (Y) inline closures . 20 6.4 Dimensions of (H) inline closures . 21 6.5 Dimensions of (U) inline closures . 22 7 Tests 22 7.1 Sample size . 22 7.2 Test sequence 22 7.3 Pass/fail crite
8、ria . 23 8 Test report . 23 9 Performance requirements 24 9.1 Dimensional and marking requirements 24 9.2 Appearance performance criteria 24 9.3 Mechanical performance requirements . 25 9.4 Environmental performance requirements 27 BS EN 50411-2-9:2010 5 EN 50411-2-9:2010 Annex A (informative) Sampl
9、e size and product sourcing requirements 29 Annex B (informative) Closure minimum internal diameters, containing microduct connectors . 30 Annex C (informative) Typical buried subterranean blown fibre microduct cable outside diameters 34 Annex D (informative) Microduct definitions and sketches . 35
10、Annex E (informative) Microduct minimum bend radius 38 Annex F (informative) Typical (U) closure configurations 39 Figures Figure 1 Closures configurations . 8 Figure 2 Schematic Minimum microduct and connector space profile (see Annex B) 13 Figure 3 (I) Single port ended 13 Figure 4 (T) Single entr
11、y port ends with a single port at 90 . 14 Figure 5 (Y) 14 Figure 6 (H) Inline double entry ports at each ends 14 Figure 7 (U) Multiple end/side entry ported closure 15 Figure 8 Diagram showing (I) inline Closures dimensions. 19 Figure 9 (T) Diagram showing Closures dimensions . 20 Figure 10 (Y) Diag
12、ram showing Closures dimensions . 20 Figure 11 (H) Diagram showing Closures dimensions 21 Figure 12 (U) Diagram showing Closures dimensions 22 Figure 13 Track joint configuration sample 23 Figure 14 Spur joint configuration sample . 23 Figure 15 Distribution joint configuration sample . 23 Figure B.
13、1 Schematic Minimum microduct and connector space profile 30 Figure D.1 Straight microduct connectors . 35 Figure D.2 Straight bulkhead microduct connectors 35 Figure D.3 ID/OD/ID and OD reducer/enlarger stem microduct connectors 35 Figure D.4 ID/OD/ID and OD reducer/enlarger microduct connectors 36
14、 Figure D.5 Close down microduct connectors 36 Figure D.6 Liquid block microduct connectors . 36 Figure D.7 Liquid block with a barb end 36 Figure D.8 End stop microduct connectors 37 Figure F.1 Universal UA Inline closure . 39 Figure F.2 Universal UB Inline closure . 39 Figure F.3 Universal UC Inli
15、ne closure . 39 Figure F.4 Universal UD Inline closure . 40 Tables Table 1 Variants for sealed closures for ABF protected microduct, for category S - EN 61753-1: Category S: subterranean environment; Category A: aerial environment. 1.3 Test severity The test severities are based on IP40 (see EN 6052
16、9). The test criteria for all mechanical and environmental tests cover visual appearance, and protected microduct retention of the closure. It is generally accepted practice that liquids will enter the closure through its body or connected ducts. 1.4 Reliability Whilst the anticipated service life e
17、xpectancy of the product in this environment is a minimum of 20 years, compliance with this specification does not guarantee the reliability of the product. This should be predicted using a recognised reliability assessment programme. 1.5 Quality assurance Compliance with this specification does not
18、 guarantee the manufacturing consistency of the product. This should be maintained using a recognised quality assurance programme. 1.6 Allowed fibre and cable types This closure standard covers all IEC/EN standard optical fibre microducts, and protected microducts with their various fibre capacities
19、, types and designs. This includes optical fibre cable standard EN 60794-5. This product specification has only considered protected microduct cables containing microducts of same outside diameters. There are other hybrid protected microduct cables with microducts of differing ODs; it may be possibl
20、e to use these hybrids, however the user must verify suitability in each case. 1.7 Allowed microduct connector types This closure standard covers all EN standard microduct connectors, including: straight, reducer/enlarger stem, reducer/enlarger, close down, liquid block, liquid block with barb end,
21、and end stop connectors. This includes EN 50411-2-8. BS EN 50411-2-9:2010EN 50411-2-9:2010 8 1.8 Microduct storage constraints Microduct excess storage is not required in all air blown fibre closures. Some closure types do not have sufficient internal space to provide storage. The need for microduct
22、 storage is provided inside the closure when opened, typically to ensure that there is enough microduct to fulfil the following functions: remove the coiled microduct attached to the closedown connectors, to a remote location, close to blowing equipment, in the process uncoiling the microducts to ai
23、d blowing; provide additional microduct if repeated cut backs for connectors are planned or likely to be fitted throughout the closure life. The minimum microduct storage bend radius is based on the outside diameter and material selection, typically based on 12 times the outside diameter (below 8 mm
24、) and 20 times above. During fibre blowing the bend radius is typically 20 times the microduct diameter. 1.9 Essential differences between sealed and non-sealed ABF closures The non-sealed ABF closures covered in this product specification typically differ from sealed ABF closures in EN 50411-2-5, i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN50411292010FIBREORGANISERSANDCLOSURESTOBEUSEDINOPTICALFIBRECOMMUNICATIONSSYSTEMSPRODUCTSPECIFICATIONSNONSEALEDCLOSURESFORAIRBLOWNFIBREMICRODUCTCPDF

链接地址:http://www.mydoc123.com/p-574920.html