BS EN 50216-3-2002 Power Transformer and reactor fittings - Protective relay for hermetically sealed liquid-immersed transformers and reactors without gaseous cushion《电力变压器和反应堆配件 密.pdf
《BS EN 50216-3-2002 Power Transformer and reactor fittings - Protective relay for hermetically sealed liquid-immersed transformers and reactors without gaseous cushion《电力变压器和反应堆配件 密.pdf》由会员分享,可在线阅读,更多相关《BS EN 50216-3-2002 Power Transformer and reactor fittings - Protective relay for hermetically sealed liquid-immersed transformers and reactors without gaseous cushion《电力变压器和反应堆配件 密.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 50216-3:2002 Incorporating Amendments Nos. 1 and 2 Power transformer and reactor fittings Part 3: Protective relay for hermetically sealed liquid-immersed transformers and reactors without gaseous cushion The European Standard EN 50216-3:2002, incorporating amendments A1:2002
2、and A2:2006, has the status of a British Standard ICS 29.180 BS EN 50216-3:2002 This British Standard, having been prepared under the direction of the Electrotechnical Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 12 April 2
3、002 BSI 2006 ISBN 0 580 39500 6 National foreword This British Standard was published by BSI. It is the UK implementation of EN 50216-3:2002, incorporating amendments A1:2002 and A2:2006. The start and finish of text introduced or altered by amendment is indicated in the text by tags !“. Tags indica
4、ting changes to CEN text carry the number of the CEN amendment. For example, text altered by CEN amendment A1 is indicated in the text by !“. The UK participation in its preparation was entrusted to Technical Committee PEL/14, Power transformers. A list of organizations represented on PEL/14 can be
5、obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal obligations. Amendments issued since publication Amd.
6、 No. Date Comments 14728 4 November 2003 Changes to Table 2 16777 30 November 2006 See national forewordEUROPEAN STANDARD EN 50216-3 January 2002NORME EUROPENNE +A1 December 2002 EUROPISCHE NORM CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotec
7、hnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2002 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50216-3:2002 E ICS 29.180 English version Power transformer an
8、d reactor fittings Part 3: Protective relay for hermetically sealed liquid-immersed transformers and reactors without gaseous cushion Accessoires pour transformateurs de puissance et bobines dinductance Partie 3: Relais de protection pour transformateurs et bobines dinductance hermtiques immergs dan
9、s un liquide et sans matelas gazeux Zubehr fr Transformatoren und Drosselspulen Teil 3: Schutzrelais fr ohne Gaspolster hermetisch verschlossene flssigkeitsgefllte Transformatoren und Drosselspulen CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the cond
10、itions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in th
11、ree official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechni
12、cal committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom. +A2 October 2006EN 50216-3:2002 2 Foreword This European Standar
13、d was prepared by the Technical Committee CENELEC TC 14, Power transformers. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50216-3 on 2001-09-25. The following dates were fixed: - latest date by which the EN has to be implemented at national level by public
14、ation of an identical national standard or by endorsement (dop) 2002-10-01 - latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2004-10-01 EN 50216-3 is to be read in conjunction with EN 50216-1. Foreword to amendment A1 This amendment was prepared by the
15、Technical Committee CENELEC TC 14, Power transformers. The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as amendment A1 to EN 50216-3:2002 on 2002-11-01. The following dates were fixed: - latest date by which the amendment has to be implemented at na
16、tional level by publication of an identical national standard or by endorsement (dop) 2003-11-01 - latest date by which the national standards conflicting with the amendment have to be withdrawn (dow) 2005-11-01 Foreword to amendment A2 This amendment to the European Standard EN 50216-3:2002 was pre
17、pared by the Technical Committee CENELEC TC 14, Power transformers. The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as amendment A2 to EN 50216-3:2002 on 2006-10-01. This amendment A2 supersedes EN 50216-3:2002/A1:2002. The following dates were fixe
18、d: latest date by which the amendment has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2007-10-01 latest date by which the national standards conflicting with the amendment have to be withdrawn (dow) 2009-10-01 _ 3 EN 50216-3:2002 Conte
19、nts Page 1 Scope. 4 2 Normative references 4 3 Identification of relays 4 4 Service conditions 5 4.1 Maximum inclination.5 4.2 Operating pressure.5 4.3 Sensitivity of the relay contacts to magnetic fields 5 5 Outline and mounting details. 5 6 Operational performance5 6.1 General 5 6.2 Gas collection
20、. 5 6.3 Leakage detection 5 6.4 Pressure detection.5 6.5 Temperature detection (for relay type 2) 6 6.6 Temperature indicator6 7 Electrical characteristics of switch 6 7.1 Rated currents6 7.2 Breaking and making capacity 6 7.3 Operation time6 8 Mechanical requirements.6 8.1 Terminal box6 8.2 Testing
21、 facilities 7 8.3 Gas sampling . 7 8.4 Presence of gas in the relay. 7 9 Nameplate 7 10 Tests. 7 10.1 Routine tests 7 10.2 Type tests. 7 EN 50216-3:2002 4 1 Scope EN 50216-3 applies to protective relays for hermetically liquid-immersed transformers, complying with the EN 60076 series, and reactors,
22、complying with EN 60289, without gaseous cushions for indoor or outdoor installation. This part of EN 50216 defines the operating limits, outline and mounting details, operational performance, electrical characteristics, dynamic characteristics. Should environmental conditions and dynamic stress req
23、uirements differ from those detailed in clause 3 of EN 50216-1, EN 50216-3 may then be applied by agreement between purchaser and supplier for those parts which are not affected by such abnormal installation conditions. NOTE EN 50216-3 may be used as far as applicable for relays with mercury switche
24、s. Restrictions on the use of mercury devices may be imposed by national regulations. 2 Normative references Addition to EN 50216-1: EN 50005 1976 Low-voltage switchgear and controlgear for industrial use - Terminal marking and distinctive number - General rules EN 50102 1995 Degrees of protection p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN5021632002POWERTRANSFORMERANDREACTORFITTINGSPROTECTIVERELAYFORHERMETICALLYSEALEDLIQUIDIMMERSEDTRANSFORMERSANDREACTORSWITHOUTGASEOUSCUSHION

链接地址:http://www.mydoc123.com/p-574660.html