BS EN 50174-3-2013 Information technology Cabling installation Installation planning and practices outside buildings《信息技术 布线安装 建筑物外部的安装计划和实践》.pdf
《BS EN 50174-3-2013 Information technology Cabling installation Installation planning and practices outside buildings《信息技术 布线安装 建筑物外部的安装计划和实践》.pdf》由会员分享,可在线阅读,更多相关《BS EN 50174-3-2013 Information technology Cabling installation Installation planning and practices outside buildings《信息技术 布线安装 建筑物外部的安装计划和实践》.pdf(102页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS EN 50174-3:2013Information technology Cabling installationPart 3: Installation planning and practices outside buildingsBS EN 50174-3:2013 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 50174-3:2013.It supersedes BS EN 50174-3:2003 wh
2、ich is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee TCT/7, Telecommunications - Installation requirements.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the nec
3、essaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2013. Published by BSI StandardsLimited 2013ISBN 978 0 580 78405 7ICS 33.040.50; 35.110Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Stan
4、dard was published under the authority of theStandards Policy and Strategy Committee on 31 October 2013.Amendments issued since publicationDate Text affectedBS EN 50174-3:2013EUROPEAN STANDARD EN 50174-3 NORME EUROPENNE EUROPISCHE NORM October 2013 CENELEC European Committee for Electrotechnical Sta
5、ndardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN
6、50174-3:2013 E ICS 35.110 Supersedes EN 50174-3:2003 English version Information technology - Cabling installation - Part 3: Installation planning and practices outside buildings Technologies de linformation - Installation de cblage - Partie 3: Planification et pratiques dinstallation lextrieur des
7、btiments Informationstechnik - Installation von Kommunikationsverkabelung - Teil 3: Installationsplanung und Installationspraktiken im Freien This European Standard was approved by CENELEC on 2013-09-02. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate th
8、e conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Stan
9、dard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are
10、 the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Po
11、land, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 50174-3:2013EN 50174-3:2013 - 2 - Contents Page Foreword . 5 Introduction . 6 1 Scope and conformance 9 1.1 Scope . 9 1.2 Conformance . 10 2 Normative references . 10 3 Terms, definitions an
12、d abbreviations . 13 3.1 Terms and definitions 13 3.2 Abbreviations 15 4 Requirements for planning installations of information technology cabling . 15 4.1 Safety . 15 4.2 Documentation 17 4.3 Pathways . 17 4.4 Pathway systems 28 4.5 Pathway systems other than for core and access networks . 32 4.6 C
13、losures 36 4.7 Cabling . 37 4.8 Spaces and structures . 39 4.9 Spaces and structures other than for core and access networks 42 4.10 Administration 46 5 Requirements for the installation of information technology cabling 46 5.1 Safety . 46 5.2 Documentation 48 5.3 Installation practices 48 5.4 Label
14、ling 63 5.5 Testing . 63 5.6 Contractual acceptance . 63 5.7 Operation . 63 6 Segregation . 63 6.1 General. 63 6.2 Segregation of underground information technology cabling 64 6.3 Segregation of aerial information technology cabling . 67 6.4 Segregation with respect to specific sources of EMI . 71 7
15、 Additional installation practices for specific sites and services . 73 7.1 Hospitals 73 7.2 Airports 73 7.3 Nuclear areas 73 7.4 Chemical manufacturing areas . 74 7.5 Railways (overground and underground) 74 Annex A (informative) EMC and protection 77 A.1 Coupling mechanisms and countermeasures . 7
16、7 A.2 The EMC concept 81 A.3 Filtering and electrical isolation components and surge protective devices 82 Annex B (informative) Earth potential rise (EPR) 88 B.1 General. 88 B.2 Limit of the hot zone . 88 Annex C (informative) Application of responsibilities 90 Annex D (informative) A-deviations 93
17、 Bibliography 96 BS EN 50174-3:2013- 3 - EN 50174-3:2013 Figures Figure 1 Schematic relationship between EN 50174 series and other relevant standards 7 Figure 2 Examples of areas covered by this document . 10 Figure 3 Example of cabling installations outside buildings 18 Figure 4 Cable arrangement i
18、n a metallic section 31 Figure 5 Example of wind vibration damper . 35 Figure 6 Example of an underground conduit entrance for information technology cables into a building 43 Figure 7 Example of the use of a galvanic isolation device 44 Figure 8 Continuity of metallic cable management systems . 52
19、Figure 9 Interruption of metallic cable management systems at fire barriers. 52 Figure 10 Example showing the protection of underground information technology cables when located next to power supply cables 65 Figure 11 Separation of adjacent infrastructures . 68 Figure 12 Separation distances on su
20、pporting structures 70 Figure 13 Separation distance on supporting structures with lighting devices . 70 Figure 14 Clearance between information technology cabling and standard gauge railways 74 Figure 15 Clearances providing protection to information technology cabling against falling contact wires
21、 76 Figure A.1 Screened cables reduce capacitive coupling. 78 Figure A.2 Electrical field to cable, capacitive coupling example 79 Figure A.3 Magnetic field to loop, inductive coupling example 79 Figure A.4 Magnetic field 80 Figure A.5 Earthing arrangement . 81 Figure A.6 Earthing and bonding of fil
22、ters 83 Figure A.7 Mounting of filters . 84 Figure A.8 Installation of power filter . 84 Figure A.9 Installation guidelines for transformers . 86 Figure A.10 Installation guidelines for optocouplers . 86 Figure A.11 Short connections of surge protective devices . 87 Figure B.1 Definition of hot zone
23、 88 Tables Table 1 Contextual relationship between EN 50174 series and other standards relevant for information technology cabling systems . 8 Table 2 Design and planning of underground pathways . 19 Table 3 Requirements and recommendation for pathway depths below finished surface 20 Table 4 Design
24、and planning of dedicated aerial pathways 23 Table 5 Minimum installed clearances above ground for aerial cables . 25 BS EN 50174-3:2013EN 50174-3:2013 - 4 - Table 6 Stacking height for typical distances L 30 Table 7 Family and detailed specifications for outdoor optical fibre cables . 38 Table 8 Mi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN5017432013INFORMATIONTECHNOLOGYCABLINGINSTALLATIONINSTALLATIONPLANNINGANDPRACTICESOUTSIDEBUILDINGS

链接地址:http://www.mydoc123.com/p-574627.html