BS EN 50131-2-3-2008 Alarm systems — Intrusion nand hold-up systems — nPart 2-3 Requirements for microwave detectors《报警系统 侵入和拦截系统 微波探测器用要求》.pdf
《BS EN 50131-2-3-2008 Alarm systems — Intrusion nand hold-up systems — nPart 2-3 Requirements for microwave detectors《报警系统 侵入和拦截系统 微波探测器用要求》.pdf》由会员分享,可在线阅读,更多相关《BS EN 50131-2-3-2008 Alarm systems — Intrusion nand hold-up systems — nPart 2-3 Requirements for microwave detectors《报警系统 侵入和拦截系统 微波探测器用要求》.pdf(44页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationAlarm systems Intrusionand hold-up systems Part 2-3 : Requirements for microwave detectorsBS EN 50131-2-3:2008Incorporating corrigendum May 2014EN 50131-2-3:2008/IS1:2014 (E) 4 Text of IS1 to EN 50131-2-3:2008 Clause: Annex A and Figure A.1 Question: Would it be allowed for
2、test purposes (for test houses and manufacturers) to use the NeoDym magnet listedbelow instead of the AlNiCo version described in Annex A and Figure A.1 for reproducible tests ? Interpretation: Yes, because this will allow stable and reproducible test results, which is not guaranteed while using the
3、AlNiCo magnet due to the nature of the magnet material. Furthermore, the test magnet described belowallows a high-level degree of backward compatibility for already tested products, while it gives the stabilityrequired. Therefore, when the NeoDym magnet is used for test purposes (for test houses and
4、 manufacturers), the textbelow may be used in place of Annex A. Validity: This interpretation remains valid until an amendment or updated standard dealing with this issue is publishedby CENELEC. BS EN 50131-2-3:2008 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of E
5、N 50131-2-3:2008. Itsupersedes DD CLC/TS 50131-2-3:2004 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee GW/1, Electronic security systems, to Subcommittee GW/1/1,Alarm components.A list of organizations represented on this subcommittee can beobtained on
6、 request to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 83557 5 ICS 13.320 Compliance with a Briti
7、sh Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 31 December 2008.Amendments/corrigenda issued since publicationDate Text affected31 May 2014 Implementation of CENELEC Interpretation she
8、etFebruary 2014 in National Annex NAEN 50131-2-3:2008/IS1:2014 (E) 4 Text of IS1 to EN 50131-2-3:2008 Clause: Annex A and Figure A.1 Question: Would it be allowed for test purposes (for test houses and manufacturers) to use the NeoDym magnet listed below instead of the AlNiCo version described in An
9、nex A and Figure A.1 for reproducible tests ? Interpretation: Yes, because this will allow stable and reproducible test results, which is not guaranteed while using the AlNiCo magnet due to the nature of the magnet material. Furthermore, the test magnet described below allows a high-level degree of
10、backward compatibility for already tested products, while it gives the stability required. Therefore, when the NeoDym magnet is used for test purposes (for test houses and manufacturers), the text below may be used in place of Annex A. Validity: This interpretation remains valid until an amendment o
11、r updated standard dealing with this issue is published by CENELEC. National Annex NA (Informative)BS EN 50131-2-3:2008EN 50131-2-3:2008/IS1:2014 (E) 5 Annex A (normative) Dimensions Grade 2180 s; Grade 330 s; Grade 415 s.4.3.2 Switch on delay The detector shall meet all functional requirements with
12、in 180s of the power supply reaching itsnominal voltage as specified by the manufacturer.4.3.3 Self tests4.3.3.1 Local self testThe detector shall automatically test itself at least once every24 h according to the requirements of Tables1 and 2. If normal operation of the detectoris inhibited during
13、a local self-test, the detectorinhibition time shall be limited to a maximum of 30 s in any period of 2 h.4.3.3.2 Remote self testA detector shall process remote self tests and generate signals or messages in accordance withTables1 and 2 within 10 s of the remote self test signal being received, and
14、 shall return to normal operation within 30 s of the remote test signal being received4.4Immunity to incorrect operationThe detector shall be considered to have sufficient immunity to incorrect operation if the followingrequirements have been met. No intrusion signal or message shall be generated du
15、ring the tests.4.4.1 Immunity to microwave signal interference by fluorescent lights The detector shall not generate any signals or messages due to the operation of a fluorescent lightsource mounted nearby.BS EN 50131-2-3:2008BS EN 50131-2-3:2008EN 50131-2-3:2008 11 EN 50131-2-3:20084.5 Tamper secur
16、ityTamper security requirements for each grade of detector are shown in Table 4.4.5.1Resistance to and detection of unauthorised access to components and means of adjustmentAll components, means of adjustment and access to mounting screws, which, when interfered with,could adverselyaffect the operat
17、ion of the detector, shall be located within the detector housing.Suchaccess shall require the use of an appropriate tool and depending on the grade as specified in Table 4shall generate a tamper signal or message before access can be gained.It shall not be possible to gain such access without gener
18、ating a tamper signal or message or causingvisible damage.4.5.2Detection of removal from the mounting surfaceA tamper signal or message shall be generated if the detector is removed from its mounting surface, inaccordance with Table 4.4.5.3 Resistance to, or detection of, re-orientationWhen the torq
19、ue given in Table 4 is applied to the detector it shall not rotate more than 5.Alternatively, when the torque given in Table 4 is applied, a tamper signal or message shall begenerated before the detector has rotated by 5.4.5.4 Immunity to magnetic field interferenceIt shall not be possible to inhibi
20、t any signals ormessages with a magnet of grade dependenceaccording to Table 4. The magnet types shall be as described in Annex A.4.5.5 Detection of maskingMeans shall be provided to detect inhibition of the operation of the detector by masking according tothe requirements of Table 4.The maximum res
21、ponse time for the masking detection device shall be 180 s. Masking shall besignalled according to the requirements ofTable 2. The signals or messages shall remain for at leastas long as the masking condition ispresent. A masking signal or message shall not be reset while themasking condition is sti
22、ll present. Alternatively the masking signal or message shall be generatedagain within 180 sof being reset if the masking condition is still present.NOTE From a system design point of view itwould be preferable for masked detectors to automatically reset after the masking conditionis removed.No mask
23、ing signal or message shall be generated bynormal human movement at 1 ms-1at a distanceequal to or greater than 1 m.For detectorswhere detection of masking maybe remotely disabled the detection of masking shalloperate when the I it isnotrequired to operate when the I relative humidity25 % RH to 75 %
24、 RH; air pressure 86 kPa to 106 kPa.6.1.2General detection testing environment and proceduresManufacturers documented instructions regarding mounting and operation shall be read and appliedto all tests.6.1.3 TestingenvironmentThe detection tests require an enclosed, unobstructed area that enables te
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN50131232008ALARMSYSTEMSINTRUSIONNANDHOLDUPSYSTEMSNPART23REQUIREMENTSFORMICROWAVEDETECTORS 报警 系统 侵入

链接地址:http://www.mydoc123.com/p-574580.html