《BS EN 50131-10-2014 Alarm systems Intrusion and hold-up systems Application specific requirements for Supervised Premises Transceiver (SPT)《警报系统 入侵和滞留警报系统 监管楼宇收发器 (SPT) 的具体应用要求》.pdf》由会员分享,可在线阅读,更多相关《BS EN 50131-10-2014 Alarm systems Intrusion and hold-up systems Application specific requirements for Supervised Premises Transceiver (SPT)《警报系统 入侵和滞留警报系统 监管楼宇收发器 (SPT) 的具体应用要求》.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationAlarm systems Intrusion and hold-up systemsPart 10: Application specific requirements for Supervised Premises Transceiver (SPT)BS EN 50131-10:2014National forewordThis British Standard is the UK implementation of EN 50131-10:2014.The UK participation in its preparation was e
2、ntrusted by TechnicalCommittee GW/1, Electronic security systems, to Subcommittee GW/1/2,Installed alarm systems.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Us
3、ers are responsible for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 75231 5ICS 13.320Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of th
4、eStandards Policy and Strategy Committee on 31 August 2014.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 50131-10:2014EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 50131-10 June 2014 ICS 13.320 English Version Alarm systems - Intrusion and hold-up syste
5、ms - Part 10: Application specific requirements for Supervised Premises Transceiver (SPT) Systmes dalarme - Systmes dalarme contre lintrusion et les hold-up - Partie 10: Exigences dapplication spcifiques pour les transmetteurs des locaux surveills Alarmanlagen - Einbruch- und berfallmeldeanlagen - T
6、eil 10: Anwendungsspezifische Anforderungen an bertragungseinrichtungen (E) This European Standard was approved by CENELEC on 2014-03-10. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a nat
7、ional standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A
8、 version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulg
9、aria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzer
10、land, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CENELEC All rights of exploitation in an
11、y form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 50131-10:2014 EBS EN 50131-10:2014EN 50131-10:2014 (E) - 2 - Contents page Introduction - 4 - 1 Scope - 5 - 2 Normative references - 5 - 3 Terms, definitions and abbreviations - 6 - 3.1 Terms and definitions - 6 - 3.2 Abbrev
12、iations . - 6 - 4 General requirements - 6 - 4.1 Additional functions . - 6 - 4.2 Equipment features . - 7 - 4.3 SPT structure . - 7 - 5 Security grade - 7 - 6 Environmental performance . - 7 - 6.1 Requirements - 7 - 6.2 Environmental tests . - 7 - 7 Functional requirements . - 8 - 7.1 Tamper - 8 -
13、7.2 Monitoring of substitution. - 9 - 7.3 Wireless interconnections - 9 - 7.4 Power supply . - 10 - 8 Product documentation - 10 - 9 Marking and labelling - 10 - 10 Tests - 11 - 10.1 General - 11 - 10.2 Test conditions - 11 - 10.3 Tamper security tests - 12 - 10.4 Substitution tests . - 14 - 10.5 Po
14、wer supply . - 14 - 10.6 Documentation and marking - 16 - 10.7 Environmental and EMC tests . - 16 - Annex A (informative) Classification of SPT . - 18 - Bibliography . - 19 - Tables Table 1 Tamper protection . - 8 - Table 2 Tamper detection. - 8 - Table 3 Tool dimension for tamper detection . - 9 -
15、Table 4 Removal from mounting - 9 - Table 5 Environmental and EMC tests and severity - 17 - BS EN 50131-10:2014- 3 - EN 50131-10:2014 (E) Foreword This document (EN 50131-10:2014) has been prepared by CLC/TC 79 “Alarm systems“. The following dates are fixed: latest date by which this document has to
16、 be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-03-10 latest date by which the national standards conflicting with this document have to be withdrawn (dow) 2017-03-10 Attention is drawn to the possibility that some of the elements of th
17、is document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. The EN/TS 50131 series consists of the following parts, under the general title Alarm systems Intrusion and hold-up systems: Part 1 System requirements Par
18、t 2-2 Intrusion detectors Passive infrared detectors Part 2-3 Requirements for microwave detectors Part 2-4 Requirements for combined passive infrared and microwave detectors Part 2-5 Requirements for combined passive infrared and ultrasonic detectors Part 2-6 Opening contacts (magnetic) Part 2-7-1
19、Intrusion detectors Glass break detectors (acoustics) Part 2-7-2 Intrusion detectors Glass break detectors (passive) Part 2-7-3 Intrusion detectors Glass break detectors (active) Part 2-8 Intrusion detectors Shock detectors Part 2-9 1)Intrusion detectors Active infrared detectors Part 3 Control and
20、indicating equipment Part 4 Warning devices Part 5-1 1)Requirements for wired interconnection for I b) weights and dimensions; c) fixing details d) where there are user serviceable parts (e.g. fuses) their type and value; e) type of interconnections (interface to CIE); f) terminal identifications; g
21、) the average current consumption of the SPT (not applicable to SPT with type C PS) (see 7.4.1); h) lifetime of prime power source (for SPT with type C PS only); i) permitted types of power source (for SPT with type C PS), (e.g. battery type); j) the peak current consumption of the SPT; k) suitable
22、storage device type, capacity and low voltage failure threshold (where applicable); l) programmable functions provided. 9 Marking and labelling The SPT shall comply with the requirements for marking stated in EN 50131-1 and EN 50136-2 and additionally shall be marked with the standards to which the
23、SPT claims compliance (i.e. to include this standard). When space for marking of the SPT is limited, codes may be used providing these are described in the associated component documentation. When insufficient space is available for codes the component shall include means of identification which all
24、ows cross reference to documentation providing the required information BS EN 50131-10:2014- 11 - EN 50131-10:2014 (E) 10 Tests 10.1 General Where products are to be tested for compliance with this European Standard, the following tests and conditions shall apply. NOTE 1 Type X or Type Y SPT may be
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN50131102014ALARMSYSTEMSINTRUSIONANDHOLDUPSYSTEMSAPPLICATIONSPECIFICREQUIREMENTSFORSUPERVISEDPREMISESTRANSCEIVERSPT

链接地址:http://www.mydoc123.com/p-574579.html