《BS EN 13126-16-2008 Building hardware - Requirements and test methods for windows and doors height windows - Hardware for Lift&Slide windows and doors《建筑五金件 窗和门上窗的要求和试验方法 上下移动和推拉式门.pdf》由会员分享,可在线阅读,更多相关《BS EN 13126-16-2008 Building hardware - Requirements and test methods for windows and doors height windows - Hardware for Lift&Slide windows and doors《建筑五金件 窗和门上窗的要求和试验方法 上下移动和推拉式门.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 13126-16:2008Building hardware Requirements and test methods for windows and doors height windows Part 16: Hardware for Lift active sash shall function correctly. NOTE After the sliding operation crash-test all adjustment possibilities may be used to operate the sash. BS EN 131
2、26-16:2008EN 13126-16:2008 (E) 9 5.2.3 Minimum closing device resistance 5.2.3.1 Hardware without tilt function The closing device shall withstand a torque Thr, which is the threefold torque Thas calculated and recorded in accordance with 5.2.1. For example: length of the handle = 220 mm operative l
3、ength (key 4, Figure 1) = 220 mm 20 mm = 200 mm torque Th = operative length X force F = 200 mm X 100 N = 20 Nm torque Thr= 3 X Th = 3 X 20 Nm = 60 Nm NOTE Hardware with tilt function without positive control should also conform to this requirement. Upon completion of the test in accordance with 7.5
4、.1, the closing device shall operate. 5.2.3.2 Hardware with tilt function and with positive control The hardware shall withstand a torque Thr, which is the threefold torque Thas calculated and recorded in accordance with 5.2.1. For example: length of the handle = 220 mm operative length (key 4, Figu
5、re 1) = 220 mm 20 mm = 200 mm torque Th = operative length X force F = 200 mm X 100 N = 20 Nm torque Thr= 3 X Th = 3 X 20 Nm = 60 Nm Upon completion of the test in accordance with 7.5.2.1 and 7.5.2.2, the closing device shall operate. 5.2.4 Resistance to additional loading After the additional loadi
6、ng test in accordance with 7.6 the active sash shall not drop and shall still be constrained by its fixings. NOTE It is not necessary for the sash to operate during and after the additional loading test. 5.2.5 Static endurance test at ambient temperature An additional endurance test at ambient tempe
7、rature in accordance with 7.7 is required. Before and upon completion of the endurance test in accordance with 7.7, no roll shall deviate by more than 0,5 % of its initial diameter. 6 Test equipment 6.1 General The specimen shall be installed in a test rig for testing as specified in Figure A.1 in a
8、ccordance with the manufacturers fixing instructions. All tolerances shall be %30+unless otherwise specified. BS EN 13126-16:2008EN 13126-16:2008 (E) 10 6.2 Specimen Hardware sets for Lift maximum sash dimensions (in accordance with the manufacturers product documentation) number and location of loc
9、king points. The specimen to be tested shall correspond in function, shape and material for which the hardware is intended. The dimensions of the specimen shall conform to 4.10. The hardware tested should be in accordance with the manufacturers recommendations for size and mass of the test specimen.
10、 7 Test procedure 7.1 Samples Four samples shall be tested in accordance with this part of this European Standard: sample A1 durability test sample A2 static endurance test at ambient temperature sample B corrosion test sample C retained for reference control NOTE 1 Alternatively sample A1 and A2 ma
11、y be the same. NOTE 2 Sample B should only be necessary if no test report can be supplied by the manufacturer regarding the testing of the hardware component or set in accordance with EN 1670. NOTE 3 Sample C should be retained by the test institute for the duration of the validity of the test repor
12、t. 7.2 Procedure Use sample A1. Inspect the rolls for surface imperfections. Inspect and ensure that the installed hardware set is in accordance with the manufacturers instructions. Install the hardware for Lift the procedure is as follows: initial position of the active sash is the locked closed po
13、sition. hardware is moved jerk and jolt-free into an operating position, in which the tilted position is reached. In this position the sash remains for 1 s so that it can settle. hardware is brought back to the initial position; this is the locked closed position. Then the hardware remains in this i
14、nitial position for 1 s and can settle before the next test cycle is started. NOTE The velocity with which the hardware is operated results from the predetermined rate of 200 cycle/h, the indicated interval times and the jerk and jolt-free initiation of all movements. 7.3.1.1.2 Tilt cycles on hardwa
15、re without positive control Tilt cycles for hardware with tilt function and without positive control shall be at a rate (rate) of 200 cycles/h; the procedure shall be as follows: initial position of the active sash is the locked closed position. BS EN 13126-16:2008EN 13126-16:2008 (E) 12 hardware is
16、 moved into an operating position, in which the tilted position can be enabled. active sash is moved jerk and jolt-free into the tilting position from the closed position. The sash shall freefall into the tilt position; (for example the pneumatic cylinder is decoupled or the valves open before the f
17、inal tilt position). 5 mm before the final tilt position, the velocity shall be 0,5 m/s ( 10 %). In the tilt position the active sash is held by the scissors-stay arm(s). The sash remains for 1 s in this position to allow it to settle. active sash is brought back to the initial position, whereby the
18、 locked closed position is reached again; the initiation of movement shall be jerk and jolt-free. The hardware then remains in the initial position for 1 s before the next test cycle is started. NOTE Unless otherwise stated, the velocity with which the hardware is operated results from the predeterm
19、ined rate of 200 cycle/h, the indicated interval times and the jerk and jolt-free initiation of all movements. 7.3.1.2 Lifting cycles Lifting cycles shall be at a rate of 200 cycles/h; the procedure shall be as follows: active sash shall be in the locked closed position. lifting action is started vi
20、a the hardware in a jerk and jolt-free manner, whereby the active sash is brought into the sliding position. The sash remains in this position for 1 s, so that it can settle. active sash is moved in the sliding position in the direction of the opening position in such a manner that it comes to a hal
21、t 3 mm before the locking position. The sash remains in this position for 1 s, so that it can settle. active sash is brought back to the initial position via the hardware, in doing so the locked closed position is reached again; the initiation of movement shall be jerk and jolt-free. The hardware th
22、en remains in the initial position for 1 s, before the next test cycle is started. NOTE 1 Unless otherwise stated, the velocity with which the hardware is operated results from the predetermined rate of 200 cycle/h, the indicated interval times and the jerk and jolt-free initiation of all movements.
23、 NOTE 2 Hardware systems, where the sash itself is not lifted but a gasket mechanism is moved, should be tested with the gasket mechanism moved. BS EN 13126-16:2008EN 13126-16:2008 (E) 13 7.3.1.3 Sliding cycles Sliding cycles shall be at a rate of 200 cycles/h; the procedure shall be as follows: ini
24、tial position of the active sash is in the closed position. movement range results from the sash width of the testing-element minus 200 mm (for example: a sash width of 1 200 mm results in a movement range of 1 000 mm). active sash is moved along a predetermined movement range while in the sliding p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN13126162008BUILDINGHARDWAREREQUIREMENTSANDTESTMETHODSFORWINDOWSANDDOORSHEIGHTWINDOWSHARDWAREFORLIFTSLIDEWINDOWSANDDOORS

链接地址:http://www.mydoc123.com/p-571130.html