《BS DD ENV 737-6-2003 Medical gas pipeline systems Dimensions and allocation of probes for terminal units for compressed medical gases and vacuum《医用气体管道系统 压缩医用气体终端设备和真空终端设备用探针的尺寸和定位.pdf》由会员分享,可在线阅读,更多相关《BS DD ENV 737-6-2003 Medical gas pipeline systems Dimensions and allocation of probes for terminal units for compressed medical gases and vacuum《医用气体管道系统 压缩医用气体终端设备和真空终端设备用探针的尺寸和定位.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、DRAFT FOR DEVELOPMENT DD ENV 737-6:2003 Medical gas pipeline systems Part 6: Dimensions and allocation of probes for terminal units for compressed medical gases and vacuum ICS 11.040.10; 23.040.60 DD ENV 737-6:2003 This Draft for Development was published under the authority of the Standards Policy
2、and Strategy Committee on 29 April 2003 BSI 29 April 2003 ISBN 0 580 41648 8 National foreword This Draft for Development is the English language version of ENV 737-6:2003, which is a Special Status European Prestandard. This publication is not to be regarded as a British Standard. It is being issue
3、d in the Draft for Development series of publications and is of a provisional nature because of the reasons given in the Foreword to ENV 737-6, i.e. principally to allow existing national standards for probes to continue in existence so that probes complying with the dimensions specified in those st
4、andards may continue to be used for new medical gas installations and the extension and maintenance of existing installations. It should be applied on this provisional basis, so that information and experience of its practical application may be obtained. BS 5682:1998 will remain in effect. A Specia
5、l Status European Prestandard differs from an ENV or Technical Specification by being exempt from the necessity of regular review as to suitability for its conversion into a European Standard, although such reviews can be undertaken should circumstances indicate. If such a review is undertaken in fu
6、ture, comments arising from the use of this Draft for Development will be requested so that UK experience can be reported to the European organization responsible for its proposed conversion into a European Standard. Notification of the start of any such review period will be made in an announcement
7、 in the appropriate issue of Update Standards and, according to the replies received by the end of the review period, the responsible BSI Committee will decide whether to support the conversion of ENV 737-6 into a European Standard or to withdraw it. Comments relating to experience of the use of DD
8、ENV 737-6 should be sent in writing to the Secretary of BSI Technical Committee CH/121/6, Medical gas supply systems, at 389 Chiswick High Road, London W4 4AL, giving the document reference and clause number and proposing, where appropriate, suggestions for revision of the text. A list of organizati
9、ons represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Corresponden
10、ce Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. Summary of pages This document comprises a front cover, an inside front cover, the ENV title page, pages 2 to 14, an inside back cover and a back cover. The BSI copyright date displayed in th
11、is document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEANPRESTANDARD PRNORMEEUROPENNE EUROPISCHEVORNORM ENV7376 March2003 ICS11.040.10;23.040.60 Englishversion MedicalgaspipelinesystemsPart6:Dimensionsand allocationofprobesforterminal
12、unitsforcompressedmedical gasesandvacuum SystmededistributiondegazmdicauxPartie6: Dimensionsetattributiondesemboutspourprisesmurales pourgazmdicauxcomprimsetpourlevide(aspiration) RohrleistungssystemefrmedizinischeGaseTeil6: MaeundZuordnungvonSteckernfrEntnahmestellenfr medizinischeDruckgaseundVakuu
13、m ThisEuropeanPrestandard(ENV)wasapprovedbyCENon18December2002asaprospectivestandardforprovisionalapplication. TheperiodofvalidityofthisENVislimitedinitiallytothreeyears.AftertwoyearsthemembersofCENwillberequestedto submittheir comments,particularlyonthequestionwhethertheENVcanbeconvertedintoaEurope
14、anStandard. CENmembersarerequiredtoannouncetheexistenceofthisENVinthesamewayasforanENandtomaketheENVavailablepromp tly atnationallevelinanappropriateform.Itispermissibletokeepconflictingnationalstandardsinforce(inparalleltothe ENV)untilthefinal decisionaboutthepossibleconversionoftheENVintoanENisrea
15、ched. CENmembersarethenationalstandardsbodiesofAustria,Belgium,CzechRepublic,Denmark,Finland,France,Germany,Greece, Hungary,Iceland,Ireland,Italy,Luxembourg,Malta,Netherlands,Norway,Portugal,Slovakia,Spain,Sweden,SwitzerlandandUn ited Kingdom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMAL
16、ISATION EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050Brussels 2003CEN Allrightsofexploitationinanyformandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.ENV7376:2003EENV7376:2003(E) 2 Contents page Foreword3 Introduction .4 1 Scope 5 2 Normativereferences 5 3 Termsandd
17、efinitions. .6 4 Usesofprobes .7 5 Dimensions.7 6 Allocation7 Bibliography 14ENV7376:2003(E) 3 Foreword Thisdocument(ENV7376:2003)hasbeenpreparedbyTechnicalCommitteeCEN/TC215“Respiratoryand anaestheticequipment“thesecretariatofwhichisheldbyBSIasaSpecialStatusEuropeanPrestandard(ENV). EN737consistsof
18、thefollowingPartsunderthegeneraltitle“Medicalgaspipelinesystems”: Part1: Terminalunitsforcompressedmedicalgasesandvacuum Part2: AnaestheticgasscavengingdisposalsystemsBasicrequirements Part3: Pipelinesforcompressedmedicalgasesandvacuum Part4: Terminalunitsforanaestheticgasscavengingsystems Part6: Di
19、mensionsandallocationofprobesforterminalunitsforcompressedmedicalgasesandvacuum Takingintoaccountthat: thereareCENmembercountriesusingterminalunitsandprobeswhichcomplywithEN7371andwhich havedimensionsofprobescomplyingwiththenationalstandardsofAustria(NORM7387series),France (AFNORNFS90116),Germany(DI
20、N13260,Teil2),Italy(UNI9507),Sweden(SS8752430)andUnited Kingdom(BS5682); thereareCENmembercountriesusingterminalunitsandprobesofexistingproprietarydesignwhich complywithEN7371andwhichhavepublishedgasspecificdimensionsandtolerances; someofthesenationalstandardsandproprietarydesignshaveaspecialstatusd
21、efinedbylawor regulationandcannotthereforebechangedorwithdrawn; thisdocumentispublishedasaSpecialStatusEuropeanPrestandard(ENV)forthefollowingreasons: CENmemberswillnotbeboundtoimplementtheENV;theyneedonlymaketheENVavailableatnational levelintheformofe.g.“Draftfordevelopment“; thedimensionsofprobesg
22、ivenintheconflictingnationalstandardslistedabovewillnotbewithdrawnandmay bekeptinforceinparalleltothosegivenintheEuropeanPrestandard; terminalunitsandprobeswhichcomplywithEN7371andwhichhavedimensionscomplyingwiththe conflictingnationalstandardslistedabovemaycontinuetobeinstalledandusedforbothnewinst
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSDDENV73762003MEDICALGASPIPELINESYSTEMSDIMENSIONSANDALLOCATIONOFPROBESFORTERMINALUNITSFORCOMPRESSEDMEDICALGASESANDVACUUM

链接地址:http://www.mydoc123.com/p-548281.html