BS DD CEN TS 15810-2008 Graphical symbols nfor use on integrated nbuilding automation nequipment《综合建筑自动化设备用图形符号》.pdf
《BS DD CEN TS 15810-2008 Graphical symbols nfor use on integrated nbuilding automation nequipment《综合建筑自动化设备用图形符号》.pdf》由会员分享,可在线阅读,更多相关《BS DD CEN TS 15810-2008 Graphical symbols nfor use on integrated nbuilding automation nequipment《综合建筑自动化设备用图形符号》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、DD CEN/TS15810:2008ICS 01.080.20; 91.140.01NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWDRAFT FOR DEVELOPMENTGraphical symbolsfor use on integratedbuilding automationequipmentThis Draft for Developmentwas published under theauthority of the StandardsPolicy and StrategyCommit
2、tee on 31 December2008 BSI 2008ISBN 978 0 580 62159 8Amendments/corrigenda issued since publicationDate CommentsDD CEN/TS 15810:2008National forewordThis Draft for Development is the UK implementation of CEN/TS15810:2008.This publication is not to be regarded as a British Standard.It is being issued
3、 in the Draft for Development series of publications andis of a provisional nature. It should be applied on this provisional basis,so that information and experience of its practical application can beobtained.Comments arising from the use of this Draft for Development arerequested so that UK experi
4、ence can be reported to the internationalorganization responsible for its conversion to an international standard.A review of this publication will be initiated not later than 3 years afterits publication by the international organization so that a decision can betaken on its status. Notification of
5、 the start of the review period will bemade in an announcement in the appropriate issue of Update Standards.According to the replies received by the end of the review period,the responsible BSI Committee will decide whether to support theconversion into an international Standard, to extend the life
6、of theTechnical Specification or to withdraw it. Comments should be sent tothe Secretary of the responsible BSI Technical Committee at BritishStandards House, 389 Chiswick High Road, London W4 4AL.The UK participation in its preparation was entrusted to TechnicalCommittee RHE/16, Performance require
7、ments for control systems.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cann
8、ot confer immunityfrom legal obligations.DD CEN/TS 15810:2008TECHNICAL SPECIFICATIONSPCIFICATION TECHNIQUETECHNISCHE SPEZIFIKATIONCEN/TS 15810November 2008ICS 01.080.20; 91.140.01English VersionGraphical symbols for use on integrated building automationequipmentSymboles graphiques utiliser sur les q
9、uipementsdautomatisation intgre de btimentGraphische Symbole auf Einrichtungen der integriertenGebudeautomationThis Technical Specification (CEN/TS) was approved by CEN on 9 June 2008 for provisional application.The period of validity of this CEN/TS is limited initially to three years. After two yea
10、rs the members of CEN will be requested to submit theircomments, particularly on the question whether the CEN/TS can be converted into a European Standard.CEN members are required to announce the existence of this CEN/TS in the same way as for an EN and to make the CEN/TS availablepromptly at nation
11、al level in an appropriate form. It is permissible to keep conflicting national standards in force (in parallel to the CEN/TS)until the final decision about the possible conversion of the CEN/TS into an EN is reached.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus
12、, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EU
13、ROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2008 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. CEN/TS 15810:2008: EDD CEN/TS 15810:2008CEN/TS 15810:2008 (E) 2 Contents Pag
14、e Foreword 3 1 Scope 5 2 Normative references 5 3 Terms and definitions .5 4 Symbols overview6 5 Symbols tables .6 5.1 General 6 5.2 Elementary symbols 7 5.3 Symbols 9 Bibliography . 24 DD CEN/TS 15810:2008CEN/TS 15810:2008 (E) 3 Foreword This document (CEN/TS 15810:2008) has been prepared by Techni
15、cal Committee CEN/TC 247 “Building Automation, Controls and Building Management”, the secretariat of which is held by SNV. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identi
16、fying any or all such patent rights. For application to building automation equipments, this European Document takes up some symbols and their titles without modification from international documents ISO 7000 or IEC 60417-1. Some other existing symbols actually present on devices of the market compl
17、ete these symbols. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to announce this Technical Specification: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, I
18、celand, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. DD CEN/TS 15810:2008CEN/TS 15810:2008 (E) 4 Introduction This international document presents graphical symbols for use
19、 on control, integrated automation equipment or technical building management equipments and systems. Ease of use automation functionalities requires clear graphical symbols, readable independently of language, i.e. internationally recognising. For building energy performance, it is important to tak
20、e account expected behaviour of people encouraged to save energy through building automation equipment. Ease of use is a prime means to get realistic performance during exploitation. Professionals or end users are able to reduce largely energy consumptions by setting easily operating modes and funct
21、ions parameters for best adaptation of mechanical services functionalities to needs. For this purpose, graphical symbols constitute the best readable mean, mainly if these graphical elements are largely, internationally used by manufacturers of control, integrated automation equipment or technical b
22、uilding management equipments and systems. NOTE This document, therefore, is contributing to the general European policy for energy saving, particularly in the fields of the Construction Products Directive (89/106/EEC) Essential Requirements n 6 Energy economy and heat retention (and its interpretat
23、ive document) and of the Energy Performance of Building Directive (2002/91/CE). DD CEN/TS 15810:2008CEN/TS 15810:2008 (E) 5 1 Scope This document provides a synopsis of graphical symbols which are intended to be placed on building equipments and/or technical documentation of products in order to ins
24、truct the person(s) using the equipments. These graphical symbols are primary intended: to identify control or automation or technical management equipments or part of these equipments: electronic devices (e.g. controller, scheduler, optimiser, etc.), sensors, actuators, to indicate functions and th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSDDCENTS158102008GRAPHICALSYMBOLSNFORUSEONINTEGRATEDNBUILDINGAUTOMATIONNEQUIPMENT 综合 建筑 自动化 备用 图形 符号

链接地址:http://www.mydoc123.com/p-548150.html