BS 7977-2-2003 Specification for safety and rational use of energy of domestic gas appliances - Combined appliances - Gas fire back boiler《家用燃气用具能量的合理使用和安全性规范 组合设备 燃气锅炉 家用热水炉》.pdf
《BS 7977-2-2003 Specification for safety and rational use of energy of domestic gas appliances - Combined appliances - Gas fire back boiler《家用燃气用具能量的合理使用和安全性规范 组合设备 燃气锅炉 家用热水炉》.pdf》由会员分享,可在线阅读,更多相关《BS 7977-2-2003 Specification for safety and rational use of energy of domestic gas appliances - Combined appliances - Gas fire back boiler《家用燃气用具能量的合理使用和安全性规范 组合设备 燃气锅炉 家用热水炉》.pdf(82页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 7977-2:2003 Incorporating Corrigendum No. 1 Specification for safety and rational use of energy of domestic gas appliances Part 2: Combined appliances: Gas fire/back boiler ICS 91.140.10; 91.140.65; 97.100.20 BS 7977-2:2003 This British Standard was published under the authority
2、of the Standards Policy and Strategy Committee on 14 May 2003 BSI 13 June 2003 The following BSI references relate to work on this British Standard: Committee reference GSE/36 Draft for comment 95/717426 DC ISBN 0 580 41511 2 Committees responsible for this British Standard The preparation of this B
3、ritish Standard was entrusted to Technical Committee GSE/36, Independent gas-fired space heaters, upon which the following bodies were represented: Calor Gas Ltd. Consumer Policy Committee of BSI Department of Trade and Industry (Consumer Safety Unit) Department of the Environment Transport and Road
4、s (represented by the Building Research Establishment) Electricity Association Royal Society for the Prevention of Accidents Society of British Gas Industries Amendments issued since publication Amd. No. Date Comments 14517 Corrigendum No. 1 13 June 2003 Changes to title and supersession details in
5、national forewordBS 7977-2:2003 BSI 13 June 2003 i Contents Page Committees responsible Inside front cover Foreword iii 1S c o p e 1 2 Normative references 1 3T e r m s a n d D e f i n i t i o n s 2 3.1 Appliance and parts 2 3.2 Parts of the appliance conveying gas to the burners 2 3.3 The burner 3
6、3.4 Burner control systems 4 3.5 Construction 4 3.6 Auxiliary equipment 5 3.7 Gases 5 3.8 Appliance performance 7 3.9 Gas combustion 8 3.10 lint assessment 9 4 Classification of appliances 9 4.1 Classification according to the nature of the gases used (categories) 9 4.2 Conversion to different gases
7、 9 5 Construction 10 5.1 Materials and method of construction 10 5.2 Accessibility for maintenance and use 10 5.3 Connections to the gas and water pipes 10 5.4 Flue system 11 5.5 Soundness 11 5.6 Supply of combustion air and evacuation of the combustion products 12 5.7 Assembly 12 5.8 Electrical equ
8、ipment 12 5.9 Operational safety in the event of fluctuation, interruption and restoration of the auxiliary energy 12 5.10 Confirmation of operation 12 5.11 Requirements for adjusting, control and safety devices 13 5.12 Burners 18 6 Test conditions 19 6.1 Test gases 19 6.2 Conditions of test 21 7 Re
9、quirements and test methods 23 7.1 Soundness 23 7.2 Heat input 25 7.3 Limiting temperatures 27 7.4 Ignition-cross lighting and flame-stability 29 7.5 Delayed ignition 31 7.6 Control devices 31 7.7 Combustion 32 7.8 Lint assessment 35 7.9 Guarding (Fires only) 36 7.10 Spillage monitoring 37 7.11 Cycl
10、ic use test fire only 39 7.12 Products clearance 40 7.13 Flame supervision device 40 7.14 Useful efficiency at nominal heat input 42BS 7977-2:2003 ii BSI 13 June 2003 Page 7.15 Useful efficiency at part load (back boiler only) 44 7.16 Hydraulic resistance 46 7.17 Stability of the fire 47 7.18 Thermo
11、stats and water temperature limiting devices 47 8 Marking and instructions 48 8.1 General 48 8.2 Appliance marking 48 8.3 Dress guard 48 8.4 Warning labels 48 8.5 Packaging 48 8.6 Name badge 48 8.7 User instructions 49 8.8 Installation instructions 49 8.9 Conversion instructions 50 Annex A (normativ
12、e) Lint Method of test for resistance to airborne lint 67 Annex B (informative) Composition of the gas circuit 69 Annex C (informative) GAD essential requirements guide 72 Bibliography 74 Figure 1 Test box and flue 51 Figure 2 Collecting hood 52 Figure 3 Apparatus for measuring floor and wall temper
13、atures 54 Figure 4 Probe for dress guard test 55 Figure 5 Atmosphere sensing test room 56 Figure 6 Gas fire efficiency test rig 57 Figure 7 Sealing plate 58 Figure 8 Sampling probe 59 Figure 9 Mean specific heat of combustion products 60 Figure 10 Boiler test rig 61 Figure 11 Hydraulic resistance 63
14、 Figure 12 Position of baffle with respect to lint generator outlet duct 64 Figure 13 Lint generator 65 Figure 14 Lint filter 66 Figure B.1 Direct ignition of the main burner 69 Figure B.2 Ignition of the main burner by an ignition burner (see Clause 7.2.6)7 4 Figure B.3 Alternating ignition burner
15、71 Table 1 Classification of gases 9 Table 2 Gas valves for semi-automatic control systems 15 Table 3 Gas valves for automatic control systems with start-gas ignition 16 Table 4 Characteristics of the test gases gas dry at 15 C and 1,013.25 mbar 20 Table 5 The calorific values of the third family te
16、st gases 20 Table 6 Test pressure (mbar) 21 Table 7 (CO 2 ) Nfor test gases 33 Table 8 Products discharge times 39 Table 9 Gas fire efficiency 42 Table 10 Test gas data 43 Table 11 Useful boiler efficiency 43BS 7977-2:2003 BSI 13 June 2003 iii Foreword This standard has been prepared under the direc
17、tion of the Engineering Section Board, E/-, and is a revision of BS 5258-8:1989 and BS 6332-3:1984, all of which will be withdrawn, on publication of this standard. Matters related to quality assurance systems, tests during production and to certificates of conformity of auxiliary devices are not de
18、alt with. The test gases, test pressures and appliance categories specified in this standard are in accordance with those specified in BS EN 437. A Guide to the clauses of this British Standard addressing the Essential Requirements of the Gas Appliance Directive (GAD) is given in Annex C. In particu
19、lar attention is drawn to the following: The Gas Appliances (Safety) Regulations 1995 SI No. 16291. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer
20、 immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i to iv, pages 1 to 74, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued.iv blankBS 7977-2:2003
21、 BSI 13 June 2003 1 1 Scope This standard specifies the requirements and methods of test for the construction, safety, performance, classification and marking of gas-fired appliances consisting of a back boiler and a gas fire. These appliances are intended for installation with a governed or regulat
22、ed gas supply. This standard applies to open flued appliances using 2 ndand/or 3 rdfamily gases only. This standard does not apply to: back circulators; catalytic combustion appliances; appliances in which the supply of combustion air, or the movement of convected air, is achieved by mechanical mean
23、s; appliances intended for direct heating of sanitary water; gas fires with a range-rating capability. This standard only covers type testing. 2 Normative references The following referenced documents are indispensible for the application of this document. For dated references, only the edition cite
24、d applies. For undated references, the latest edition of the referenced document (including any amendments) applies. BS 1179:1967, Glossary of terms used in the gas industry. BS 5258-8:1980, Safety of domestic gas appliances Combined appliances: Gas fire/back boiler. BS EN 88:1991, Pressure governor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS797722003SPECIFICATIONFORSAFETYANDRATIONALUSEOFENERGYOFDOMESTICGASAPPLIANCESCOMBINEDAPPLIANCESGASFIREBACKBOILER

链接地址:http://www.mydoc123.com/p-547225.html