BS 7917-1999 Elastomer insulated fire resistant (limited circuit integrity) cables for fixed wiring in ships and on mobile and fixed offshore units - Requirements and test methods《.pdf
《BS 7917-1999 Elastomer insulated fire resistant (limited circuit integrity) cables for fixed wiring in ships and on mobile and fixed offshore units - Requirements and test methods《.pdf》由会员分享,可在线阅读,更多相关《BS 7917-1999 Elastomer insulated fire resistant (limited circuit integrity) cables for fixed wiring in ships and on mobile and fixed offshore units - Requirements and test methods《.pdf(46页珍藏版)》请在麦多课文档分享上搜索。
1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS 7917:1999 ICS 47.020.6
2、0 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Elastomer insulated fire resistant (limited circuit integrity) cables for fixed wiring in ships and on mobile and fixed offshore units Requirements and test methodsThis British Standard, having been prepared under the direction
3、 of the Electrotechnical Sector Committee, was published under the authority of the Standards Committee and comes into effect on 15 June 1999 BSI 06-1999 The following BSI references relate to the work on this standard: Committee reference GEL/20/6 Draft for comment 96/214276 DC ISBN 0 580 33003 6 B
4、S 7917:1999 Amendments issued since publication Amd. No. Date Comments Committees responsible for this British Standard The preparation of this British Standard was entrusted by Technical Committee GEL/20, Electric cables, to Subcommittee GEL/20/6, Ships cables, upon which the following bodies were
5、represented: British Cable Makers Confederation Institute of Marine Engineers Lloyds Register of Shipping Ministry of Defence UK Offshore Operators Association LimitedBS 7917:1999 BSI 06-1999 i Contents Page Committees responsible Inside front cover Foreword iii 1 Scope 1 2 Normative references 1 3
6、Terms and definitions 1 4 Designation of cables 2 5 General requirements 2 6 Cables 150/250 V (pairs, triples and quads) 5 7 Single-core and multicore cables 600/1 000 V, 1 900/3 300 V and 3 300/3 300 V 14 Annex A (informative) Recommendations for the selection of cables and information on cable ope
7、rating temperatures 28 Annex B (informative) Recommendations for the installation of cables 29 Annex C (normative) Measurement of thickness 30 Annex D (normative) Voltage test 30 Annex E (normative) Insulation resistance tests 31 Annex F (normative) Compatibility test 31 Annex G (informative) Guidan
8、ce on type tests 32 Annex H (informative) Guide to use 34 Bibliography 38 Table 1 Requirements for type SB 1 material 3 Table 2 Diameter of braiding wires 3 Table 3 List of tests applicable to the cables specified in clause 6 8 Table 4 Schedule of tests 8 Table 5 Compatibility requirements 9 Table 6
9、 Elastomer insulated, individually screened pairs, sheathed 150/250 V 10 Table 7 Elastomer insulated, collectively screened pairs, sheathed 150/250 V 10 Table 8 Elastomer insulated, individually screened pairs, sheathed, steel or bronze wire braided, sheathed 150/250 V 11 Table 9 Elastomer insulated
10、, collectively screened pairs, sheathed, steel or bronze wire braided, sheathed 150/250 V 11 Table 10 Elastomer insulated, individually screened triples, sheathed 150/250 V 12 Table 11 Elastomer insulated, collectively screened triples, sheathed 150/250 V 12 Table 12 Elastomer insulated, individuall
11、y screened triples, sheathed, steel or bronze wire braided, sheathed 150/250 V 12 Table 13 Elastomer insulated, collectively screened triples, sheathed, steel or bronze wire braided, sheathed 150/250 V 13 Table 14 Elastomer insulated, individually screened quads, sheathed 150/250 V 13 Table 15 Elast
12、omer insulated, individually screened quads, sheathed, steel or bronze wire braided, sheathed 150/250 V 13 Table 16 List of tests applicable to the cables specified in clause 7 16 Table 17 Schedule of tests 17 Table 18 Compatibility requirements 17 Table 19 Elastomer insulated, sheathed, single-core
13、, two-core, three-core and four-core cables 600/1 000 V 18 Table 20 Elastomer insulated, sheathed, 5, 7, 12, 19, 27 and 37-core cables 600/1 000 V 19BS 7917:1999 ii BSI 06-1999 Page Table 21 Elastomer insulated, sheathed, bronze wire braided, sheathed, single-core cables 600/1 000 V 19 Table 22 Elas
14、tomer insulated, sheathed, steel or bronze wire braided, sheathed, two-core cables 600/1 000 V 20 Table 23 Elastomer insulated, sheathed, steel or bronze wire braided, sheathed, three-core cables 600/1 000 V 20 Table 24 Elastomer insulated, sheathed, steel or bronze wire braided, sheathed, four-core
15、 cables 600/1 000 V 21 Table 25 Elastomer insulated, sheathed, steel or bronze wire braided, sheathed 5, 7, 12, 19, 27 and 37-core cables 600/1 000 V 21 Table 26 Elastomer insulated, sheathed, copper wire braided, sheathed, single-core cables 600/1 000 V 22 Table 27 Elastomer insulated, sheathed, co
16、pper wire braided, sheathed, two-core cables 600/1 000 V 23 Table 28 Elastomer insulated, sheathed, copper wire braided, sheathed, three-core cables 600/1 000 V 24 Table 29 Elastomer insulated, sheathed, copper wire braided, sheathed, four-core cables 600/1 000 V 25 Table 30 Elastomer insulated, she
17、athed, copper wire braided, sheathed 5, 7, 12, 19, 27 and 37-core cables 600/1 000 V 25 Table 31 Elastomer insulated and sheathed, bronze wire braided, sheathed, single-core cables 1 900/3 300 V 26 Table 32 Elastomer insulated and sheathed, steel or bronze wire braided, sheathed, three-core cables 1
18、 900/3 300 V 26 Table 33 Elastomer insulated and sheathed, bronze wire braided, sheathed, single-core cables 3 300/3 300 V 27 Table 34 Elastomer insulated and sheathed, steel or bronze wire braided, sheathed, three-core cables 3 300/3 300 V 27 Table A.1 Selection of cables for a.c. systems 28 Table
19、B.1 Minimum internal bending radius 29 Table B.2 Voltage test after installation 29 Table D.1 Test voltage on completed cable 30 Table E.1 Temperature correction factors for insulation resistance 31 Table G.1 Sample selection chart 33 Table H.1 Maximum spacing of supports 34BS 7917:1999 BSI 06-1999
20、iii Foreword This British Standard has been prepared by Subcommittee GEL/20/6. This new standard has been produced in view of the increasing demand for cables for fixed wiring in ships and on mobile and fixed offshore units having fire resistance (limited circuit integrity) in the event of fire. NOT
21、E Two categories of fire resistance are specified in this standard. Further categories are under consideration. BS 7917 complements BS 6883 which specifies a range of cables having no requirement to maintain fire resistance (limited circuit integrity) in the event of fire. The minimum and maximum di
22、ameters, both those over the inner sheath and those over the outer sheath, quoted in the relevant construction tables are indicative only and do not take into account any glanding requirements. It has been assumed in the preparation of this British Standard that the execution of its provisions will
23、be entrusted to appropriately qualified and experienced people, for whose use it has been produced. WARNING. This British Standard calls for the use of substances and/or procedures that may be injurious to health if adequate precautions are not taken. It refers only to technical suitability and does
24、 not absolve the user from legal obligations relating to health and safety at any stage. Annexes C, D, E and F are normative. Annexes A, B, G and H are informative. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS79171999ELASTOMERINSULATEDFIRERESISTANTLIMITEDCIRCUITINTEGRITYCABLESFORFIXEDWIRINGINSHIPSANDONMOBILEANDFIXEDOFFSHOREUNITSREQUIREMENTSANDTESTMETHODSPDF

链接地址:http://www.mydoc123.com/p-547165.html