《BS 7889-2012 Electric cables Thermosetting insulated non-armoured cables with a voltage of 600 1000 V for fixed installations《电缆 固定装置用600 1 000V电压热固绝缘性非铠装电缆》.pdf》由会员分享,可在线阅读,更多相关《BS 7889-2012 Electric cables Thermosetting insulated non-armoured cables with a voltage of 600 1000 V for fixed installations《电缆 固定装置用600 1 000V电压热固绝缘性非铠装电缆》.pdf(32页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS 7889:2012Electric cables Thermosetting insulated,non-armoured cables with avoltage of 600/1 000 V, forfixed installationsPublishing and copyright informationThe BSI copyright
2、notice displayed in this document indicates when the documentwas last issued. The British Standards Institution 2012Published by BSI Standards Limited 2012ISBN 978 0 580 74987 2ICS 29.060.20The following BSI references relate to the work on this standard:Committee reference GEL/20/17Draft for commen
3、t 12/30244369 DCPublication historyFirst published, October 1997Second (present) edition, October 2012Amendments issued since publicationDate Text affectedBS 7889:2012 BRITISH STANDARDContentsForeword ii1 Scope 12 Normative references 13 Terms and definitions 24 Rated voltage 35 Conductors 36 Insula
4、tion 37 Identification of cores 48 Laying up 59 Extruded optional inner covering 510 Sheath 611 Cable marking and additional information 612 Schedule of tests 813 Test conditions 914 Routine tests 1015 Sample tests 1016 Type tests 11AnnexesAnnex A (informative) Guide to use 16Annex B (normative) Com
5、patibility test 19Annex C (normative) Abrasion test 20Annex D (informative) Notes on type tests 21Annex E (normative) Green-and-yellow measurement for shaped conductors 22Bibliography 24List of figuresFigure1Anexample of the marking as used on the outer sheath of thecable 7Figure E.1 Measurement of
6、green-and-yellow for shaped conductors 23List of tablesTable 1 Schedule of tests 9Table 2 Single-core 600/1 000 V cables with circular stranded copperconductor 12Table3Two-core 600/1 000 V cables with stranded copper conductors 13Table 4 Three-core 600/1 000 V cables with stranded copper conductors
7、14Table 5 Four-core 600/1 000 V cables with stranded copper conductors 15Table 6 Five-core 600/1 000 V cables with stranded copper conductors 15Table A.1 Minimum installation radius 18Table B.1 Compatibility requirements 20Table C.1 Vertical load requirements 20Summary of pagesThis document comprise
8、s a front cover, an inside front cover, pages i to iv,pages 1 to 24, an inside back cover and a back cover.BRITISH STANDARD BS 7889:2012 The British Standards Institution 2012 iForewordPublishing informationThis British Standard is published by BSI Standards Limited, under licence fromThe British St
9、andards Institution, and came into effect on 31 October 2012. Itwas prepared by Subcommittee GEL/20/17, Low voltage cables, under theauthority of Technical Committee GEL/20, Electric cables. A list of organizationsrepresented on these committees can be obtained on request to their secretary.Superses
10、sionThis British Standard supersedes BS 7889:1997, which is withdrawn.Relationship with other publicationsBS 7889 is related to but not equivalent to IEC 60502-1.Information about this documentThis is a full revision of the standard, and introduces the following principalchanges.a) The range of cabl
11、es specified is extended to include cables with two to fivecores.b) The marking arrangements are updated and clarified.c) Test methods are updated to reflect the latest CENELEC harmonization.The new edition takes account of: BS EN 60228 (replacing BS 6360) on conductors; BS EN 50363 (replacing certa
12、in parts of BS 7655) on materials; BS EN 50395 (replacing Annex E of BS 7889:1997) on electrical tests; BS EN 50396 (replacing Annex D of BS 7889:1997) on thicknessmeasurement; BS EN 60332-1-2 (replacing BS EN 50265-2-1); BS EN 62230 (replacing BS EN 50356) on spark testing; IEC 60050-461 (replacing
13、 BS 4727-2-08).In the preparation of BS 7889, GEL/20/17 has requested that references to otherstandards for which the committee is responsible are undated, even if referringto a specific clause. It is the committees intention not to amend thefundamentals (e.g. clause numbers, material type designati
14、on) in any of thesestandards and so the latest edition applies.Product certification/inspection/testing. Users of this British Standard are advisedto consider the desirability of third-party certification/inspection/ testing ofproduct conformity with this British Standard. Users seeking assistance i
15、nidentifying appropriate conformity assessment bodies or schemes may ask BSI toforward their enquiries to the relevant association.WARNING. This British Standard calls for the use of substances and/orprocedures that can be injurious to health if adequate precautions are nottaken. It refers only to t
16、echnical suitability and does not absolve the userfrom legal obligations relating to health and safety at any stage.BRITISH STANDARDBS 7889:2012ii The British Standards Institution 2012Presentational conventionsThe provisions of this standard are presented in roman (i.e. upright) type. Itsrequiremen
17、ts are expressed in sentences in which the principal auxiliary verb is“shall”.Commentary, explanation and general informative material is presented insmaller italic type, and does not constitute a normative element.Contractual and legal considerationsThis publication does not purport to include all
18、the necessary provisions of acontract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legalobligations.BRITISH STANDARD BS 7889:2012 The British Standards Institution 2012 iiiBRITISH STANDARDBS 7889:2012This page deliberately left bla
19、nkiv The British Standards Institution 20121 ScopeThis British Standard specifies requirements and test methods for theconstruction and performance of non-armoured cables with thermosettinginsulation of rated voltages 600/1 000 V. Cables specified in this British Standardare intended for use in fixe
20、d installations in industrial areas, buildings andsimilar applications but not for burial in the ground, either directly or in ducts.The cables specified in the standard are all stranded copper conductor,thermosetting insulated, PVC sheathed types. There are single-core types, andmulti-core types (2
21、-, 3-, 4- and 5-core).The insulation and other components are suitable to permit operation of thecables at a maximum sustained conductor temperature of 90 C and for amaximum short-circuit conductor temperature of 250 C (for a maximum periodof 5 s).NOTE 1 Limitation on the temperature of the cables m
22、ay be imposed in situationswhere they could be touched, or where they could touch other materials.NOTE 2 In installations that include wiring accessories, junction boxes andconsumer units, etc., the performance of these accessories should be taken intoaccount in deciding the maximum operating temper
23、ature of the cable.NOTE 3 Annex A gives guidance on the use of these cables, Annex B gives thecompatibility test, Annex C gives the abrasion test, Annex D gives notes on type testsand Annex E gives green-and-yellow measurement for shaped conductors.2 Normative referencesThe following documents, in w
24、hole or in part, are normatively referenced in thisdocument and are indispensable for its application. For dated references, onlythe edition cited applies. For undated references, the latest edition of thereferenced document (including any amendments) applies.BS 5099, Electric cables Voltage levels
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS78892012ELECTRICCABLESTHERMOSETTINGINSULATEDNONARMOUREDCABLESWITHAVOLTAGEOF6001000VFORFIXEDINSTALLATIONS

链接地址:http://www.mydoc123.com/p-547142.html