BS 7319-11-1990 Analysis of sodium chloride for industrial use - Method for determination of iron content《工业用氯化钠的分析 第11部分 铁含量的测定方法》.pdf
《BS 7319-11-1990 Analysis of sodium chloride for industrial use - Method for determination of iron content《工业用氯化钠的分析 第11部分 铁含量的测定方法》.pdf》由会员分享,可在线阅读,更多相关《BS 7319-11-1990 Analysis of sodium chloride for industrial use - Method for determination of iron content《工业用氯化钠的分析 第11部分 铁含量的测定方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS7319-11: 1990 Analysis of sodium chloride for industrial use Part11: Method for determination of iron contentBS7319-11:1990 This BritishStandard, having been prepared under the directionof the Chemicals Standards Policy Committee, waspublished under the authorityof the Board of BS
2、Iandcomes intoeffect on 30 September1990 BSI11-1999 The following BSI references relate to the work on this standard: Committee references CIC/22, FAC/23 Draft for comment88/55624DC ISBN 0 580 18544 3 Committees responsible for this BritishStandard The preparation of this BritishStandard was entrust
3、ed by the Chemicals Standards Policy Committee (CIC/-) to Technical Committee CIC/22, upon which the following bodies were represented: British Association for Chemical Specialities Chemical Industries Association Man-made Fibres Producers Committee Soap and Detergent Industry Association Textile Re
4、search Council (FRCA) The following bodies were also represented in the drafting of the standard, through Technical Committee FAC/23: AFRC Institute of Food Research Creamery Proprietors Association Department of Trade and Industry (Laboratory of the Government Chemist) Food and Drink Federation Mil
5、k Marketing Board for Northern Ireland Royal Association of British Dairy Farmers Salt Manufacturers Association Amendments issued since publication Amd. No. Date CommentsBS7319-11:1990 BSI 11-1999 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 Principle 1 3 Reagen
6、ts 1 4 Apparatus 1 5 Procedure 1 6 Expression of results 3 7 Precision 3 Table 1 Mass of iron in standard solutions 2 Table 2 Expected iron content 2 Publication(s) referred to Inside back coverBS7319-11:1990 ii BSI 11-1999 Foreword BS7319 has been prepared under the direction of the Chemicals Stand
7、ards Policy Committee, at the request of Technical Committee FAC/23, Salt, primarily to provide appropriate methods for determination of vacuum salt for food use as specified in BS998:1990. The methods for determination were previously published as appendices to BS998:1969. A list of the Parts of BS
8、7319 is given in Part1. This Part of BS7319 is based upon a method developed on behalf of the European Committee for the Study of Salt. It supersedes Appendix K of BS998:1969 which is withdrawn. A British Standard does not purport to include all the necessary provisions of a contract. Users of Briti
9、sh Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 to4, an inside back cover and a back cover. Th
10、is standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS7319-11:1990 BSI 11-1999 1 1 Scope This Part of BS7319 specifies a photometric method, using1,10-phenanthroline, for the determination
11、 of iron in sodium chloride. The method is applicable to products having iron contents equal to or greater than1mg/kg. NOTEThe titles of the publications referred to in this Part of this BritishStandard are listed on the inside back cover. 2 Principle The principles of this Part of BS7319 are as fol
12、lows: a) the reduction of trivalent iron by hydroxylammonium chloride; and the formation of a coloured complex between divalent iron and1,10-phenanthroline in a buffered medium; b) the photometric measurement of the coloured complex at a wavelength of approximately510nm. 3 Reagents 3.1 General. Use
13、only reagents of recognized analytical grade and only water complying with grade3 of BS3978. 3.2 Hydrochloric acid, =1.19g/mL,37%(m/m) solution approximately. 3.3 Acetic acid glacial, =1.05g/mL,99% to100%(m/m) solution. 3.4 Hydroxylammonium chloride solution. Dissolve10g of hydroxylammonium chloride
14、 (NH 2 OH.HCl) in1L of water. 3.5 1,10-phenanthroline solution. Dissolve2.5g of1,10-phenanthroline hydrochloride monohydrate (C 12 H 8 N 2 .HCl.H 2 O) in1L of water. NOTEThis compound may be replaced by2.1g of 1,10-phenanthroline monohydrate (C 12 H 8 N 2 .H 2 O). 3.6 Sodium acetate solution. Dissol
15、ve500g sodium acetate trihydrate (CH 3 COONa.3H 2 O) in water and dilute to1L. 3.7 Buffer solution. Dissolve272g of sodium acetate trihydrate (CH 3 COONa.3H 2 O)(3.6) in approximately500mL of water. Add240mL of the acetic acid(3.3) to the solution. Transfer quantitatively to a1000mL one-mark volumet
16、ric flask, dilute to the mark with water and mix well. This solution has a pH of4.9. 3.8 Iron stock solution, corresponding to0.20g/L Fe. Dissolve1.4043g of ammonium iron (II) sulphate hexahydrate (NH 4 ) 2 Fe(SO 4 ) 2 .6H 2 O, weighed to the nearest0.0001g, in200mL of water. Add20mL of sulphuric ac
17、id solution( =about1.84g/mL) and cool to ambient temperature. Transfer to a1000mL one-mark volumetric flask, dilute to the mark with water and mix well. 1 mL of this solution contains 200 g of Fe. 3.9 Iron standard solution, corresponding to0.010g/L Fe. Transfer25.0mL of the standard iron solution(3
18、.8) to a500mL one-mark volumetric flask, dilute to the mark with water and mix well. 1mL of this solution contains10g of Fe. Prepare this solution at the time of use. 4 Apparatus 4.1 Ordinary laboratory equipment 4.2 Spectrometer, or photometer, fitted with filters which provide a transmission maxim
19、um between500nm and520nm. 4.3 pH meter equipped with a glass electrode and a calomel reference electrode, or pH indicator paper, covering the pH range3.5 to4.2 and indicating in0.2pH unit intervals. 5 Procedure CAUTION. Ensure that no trace of iron is introduced during the analysis by the reagents,
20、the water or the apparatus, especially the apparatus used in the preparation of the initial sample. 5.1 General Wash all new glassware used in the determination as follows: a) with brush and detergent if the sides are greasy; b) with concentrated nitric acid, followed by several rinses with water. 5
21、.2 Test portion Weigh, to the nearest0.01g, a test portion of approximately10g. 5.3 Blank test At the same time as the determination carry out a blank test following the same procedure and using the same quantities of all the reagents used for the determination but omitting the test portion. 5.4 Pre
22、paration of the calibration curve 5.4.1 Preparation of standard colorimetric solutions Add the volumes of the standard iron solution(3.9) given in Table 1 to a series of five100mL one-mark volumetric flasks. Dilute the solution in each flask to approximately50mL with water, and then add the followin
23、g: a) 0.5mL of the hydrochloric acid solution(3.2); b) 5mL of the hydroxylammonium chloride solution(3.4);BS7319-11:1990 2 BSI 11-1999 c) 5mL of the1,10-phenanthroline solution(3.5); d) 25mL of the buffer solution(3.7). Dilute to the mark with water, mix well and allow the solution to stand for10min
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS7319111990ANALYSISOFSODIUMCHLORIDEFORINDUSTRIALUSEMETHODFORDETERMINATIONOFIRONCONTENT 工业 氯化钠 分析 11

链接地址:http://www.mydoc123.com/p-546700.html