BS 6840-10-1991 Sound system equipment - Methods for specifying and measuring the characteristics of peak programme level meters《音响系统设备 第10部分 峰值音量电平表特性的规定和测量方法》.pdf
《BS 6840-10-1991 Sound system equipment - Methods for specifying and measuring the characteristics of peak programme level meters《音响系统设备 第10部分 峰值音量电平表特性的规定和测量方法》.pdf》由会员分享,可在线阅读,更多相关《BS 6840-10-1991 Sound system equipment - Methods for specifying and measuring the characteristics of peak programme level meters《音响系统设备 第10部分 峰值音量电平表特性的规定和测量方法》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS6840-10: 1991 IEC268-10: 1991 Incorporating Amendment No.1 Sound system equipment Part 10: Methods for specifying and measuring the characteristics of peak programme level meters (Implementation of CENELEC HD483.10 S1)BS6840-10:1991 This British Standard, having been prepared unde
2、r the directionof the Electronic Equipment Standards Policy Committee, was published underthe authority of the Standards Board and comes intoeffect on 30August1991 BSI 05-1999 The following BSI references relate to the work on this standard: Committee reference EEL/32 Draft for comment88/23048 DC IS
3、BN 0 580 19973 8 Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Electronic Equipment Standards Policy Committee (EEL/-) to Technical Committee EEL/32, upon which the following bodies were represented: Association for Consumer Research (
4、ACRE) Association of British Theatre Technicians Audio Engineering Society British Educational Equipment Association British Kinematograph, Sound and Television Society British Radio and Electronic Equipment Manufacturers Association British Telecommunications plc Consumer Policy Committee of BSI Fe
5、deration of British Audio Independent Television Association Independent Television Commission Institution of Electrical Engineers National Council for Educational Technology (NCET) Professional Lighting and Sound Association Radio Electrical and Television Retailers Association Royal Institute of B
6、ritish Architects Royal National Institute for the deaf Society of Cable Television Engineers Sound and Communication Industries Federation Amendments issued since publication Amd. No. Date Comments 7866 August1993 Indicated by a sideline in the marginBS6840-10:1991 BSI 05-1999 i Contents Page Commi
7、ttees responsible Inside front cover National foreword iv Foreword 2 Section 1. General 1.1 Scope 3 1.2 Normative references 3 Section 2. Conditions for specification and measurement 2.1 Conditions 3 2.2 Description of peak programme level meters 3 Section 3. Characteristics of peak programme level
8、meters 3.1 Reference indication 4 3.2 Reference input voltage and reference input level 4 3.3 Division of the scale 4 3.4 Amplitude-frequency response 4 3.5 Dynamic response 4 3.6 Pulse response 5 3.7 Dynamic linearity with scale range 5 3.8 Dynamic response below minimum calibration point 5 3.9 Del
9、ay time 5 3.10 Integration time 5 3.11 Overswing 5 3.12 Return time 5 3.13 Reversibility error 5 3.14 Input impedance 5 3.15 Distortion introduced by the peak programme level meter 5 3.16 Temperature range 6 3.17 Overload characteristic 6 3.18 Maximum input level 6 3.19 Supply voltage range 6 Sectio
10、n 4. Peak programme level meters, type I 4.1 Reference indication 6 4.2 Reference input voltage and reference input level 6 4.3 Division of the scale 6 4.4 Amplitude-frequency response 6 4.5 Dynamic response 6 4.6 Integration time 6 4.7 Overswing 7 4.8 Return time 7 4.9 Reversibility error 7 4.10 In
11、put impedance 7 4.11 Distortion introduced by the peak programme level meter 7 4.12 Temperature range 7 4.13 Overload characteristic 7 4.14 Maximum input level 7 4.15 Supply voltage range 7BS6840-10:1991 ii BSI 05-1999 Page Section 5. Peak programme level meters, type II 5.1 General 7 5.2 Reference
12、indication 8 5.3 Reference input voltage 8 5.4 Indicating instrument 8 5.5 Amplitude-frequency response 9 5.6 Dynamic response 9 5.7 Pulse response (normal mode) 9 5.8 Dynamic linearity within scale range (normal mode) 9 5.9 Dynamic response below minimum calibration point (normal mode) 10 5.10 Dela
13、y time (normal mode) 10 5.11 Integration time 10 5.12 Overswing 10 5.13 Return time 10 5.14 Reversibility error 10 5.15 Input impedance 10 5.16 Distortion introduced by the peak programme level meter 10 5.17 Temperature range 10 5.18 Overload characteristic (normal mode) 11 5.19 Maximum input level
14、11 5.20 Supply voltage range 11 Section 6. Peak programme level meters having incremental display 6.1 General 11 6.2 Number of discrete elements in the display 11 6.3 Display resolution 11 6.4 Indication of levels 11 6.5 Optical characteristics of displays 11 6.6 Operation above reference indication
15、 12 6.7 Displays using multiplex technique 12 6.8 Rate of element-switching (switch-on switch-off times) 12 Section 7. Incremental peak programme level meters for secondary and consumer applications 7.1 General 12 7.2 Reference indication 12 7.3 Number of discrete elements in the display 12 7.4 Disp
16、lay resolution 12 7.5 Amplitude-frequency response 12 7.6 Integration time 12 7.7 Return time 12 7.8 Reversibility error 12 Section 8. Classification for the characteristics to be specified 8.1 Introduction 13 8.2 Classification 13BS6840-10:1991 BSI 05-1999 iii Page Annex A (normative) Slow mode of
17、operation 16 Annex B (informative) Details of preferred indicating instrument 17 Annex ZA (normative) Other international publications quoted in this standard with the references of the relevant European publications 18 National annex NA (informative) Cross-references Inside back cover Figure 1 Pref
18、erred scale markings and dimensions for type 11a peak programme meters 14 Figure 2 Preferred scale markings for type 11b peak programme meters 15 Figure 3 Example of the display of an incremental peak programme level meter for secondary applications 15 Figure A.1 Circuit used to obtain the slow-indi
19、cation mode 16 Table 1 Dynamic response 6 Table 2 Calibration tolerances 8 Table 3 Dynamic response in normal mode 9 Table 4 Dynamic response in slow mode 9 Table 5 Drift in indicated readings 11BS6840-10:1991 iv BSI 05-1999 National foreword This Part of BS6840 has been prepared under the direction
20、 of the Electronic Equipment Standards Policy Committee and is identical with IEC268-10:1991 “Sound system equipment Part10: Peak programme level meters”, published by the International Electrotechnical Commission (IEC). This British Standard implements Harmonization Document HD483.10 S1, published
21、by the European Committee for Electrotechnical Standardization (CENELEC). This British Standard supersedes BS5428-9:1981 which is withdrawn. The purpose of this Part of BS6840 is to standardize the characteristics to be specified, the relevant methods of measurement and performance requirements (in
22、some cases) for: peak programme level meters, in general (section3); peak programme level meters, type I (section4); peak programme level meters, type II (section5); peak programme level meters having incremental displays (section6); peak programme level meters having incremental displays, for secon
23、dary and household applications (section7). In general, the methods of measurement recommended are those which are directly related to the definitions. This does not exclude the use of other methods which can be shown to give equivalent results. BS6840 consists of the following Parts: Part 1: Method
24、s for specifying and measuring general characteristics used for equipment performance (supersedes part of BS5428-1); Part 2: Glossary of general terms and calculation methods (supersedes part of BS5428-1); Part 3: Methods for specifying and measuring the characteristics of sound system amplifiers (s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS6840101991SOUNDSYSTEMEQUIPMENTMETHODSFORSPECIFYINGANDMEASURINGTHECHARACTERISTICSOFPEAKPROGRAMMELEVELMETERS

链接地址:http://www.mydoc123.com/p-546310.html