《BS 6583-1985 Methods for volumetric testing for rating of fan sections in central station air handling units (including guidance on rating)《中央通风装置风机区额定功率的体积测定试验方法(包括功率分级指南)》.pdf》由会员分享,可在线阅读,更多相关《BS 6583-1985 Methods for volumetric testing for rating of fan sections in central station air handling units (including guidance on rating)《中央通风装置风机区额定功率的体积测定试验方法(包括功率分级指南)》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 6583:1985 Methods for Volumetric testing for rating of fan sections in central station air handling units (including guidance on rating) UDC 628.83:628.922:621.63.001.4BS6583:1985 This British Standard, having been prepared under the directionof the Refrigeration, Heating and Air
2、 Conditioning Standards Committee, was published under the authority ofthe Board of BSI and comes intoeffect on 28February1985 BSI 07-1999 The following BSI references relate to the work on this standad: Committee reference RHE/6 Draft for comment 82/75373 DC ISBN 0 580 14345 7 Committees responsibl
3、e for this British Standard The preparation of this British Standard was entrusted by the Refrigeration, Heating and Air Conditioning Standards Committee (RHE/-) to Technical Committee RHE/6, upon which the following bodies were represented: Boiler and Radiator Manufacturers Association Limited Brit
4、ish Refrigeration Association Building Services Research and Information Association Chartered Institution of Building Services Department of Health and Social Security Department of the Environment (Building Research Establishment) Department of the Environment (Property Services Agency) Heating an
5、d Air Conditioning Manufacturers Association Heating and Ventilating Contractors Association Institute of Domestic Heating Engineers Institute of Refrigeration Manufacturers Association of Radiators and Convectors Ltd. Ministry of Defence Coopted member Amendments issued since publication Amd. No. D
6、ate of issue CommentsBS6583:1985 BSI 07-1999 i Contents Page Committees responsible Inside front cover Foreword ii Section 1. General 1 0 Introduction 1 1 Scope 1 2 Definitions 1 Section 2. Volumetric testing for rating of fan sections 3 3 Test unit and test installation 3 4 Methods of test 4 5 Pres
7、entation of data 4 Section 3. Extrapolation of fan section data 6 6 Extrapolation of data for fan sections that are geometrically similar 6 7 Extrapolation of data for fan sections that are geometrically similar except for the fans 6 Appendix A Guide to the rating of air handling units 9 Figure 1 Mu
8、ltiple outlet units 3 Figure 2 Horizontal blow through cooling heating unit 4 Figure 3 Derivation of test unit fan section performance 5 Figure 4 Performance characteristics: fan rated and fan section tested 7 Figure 5 Performance characteristics: fan rated and fan section calculated 8 Publications
9、referred to Inside back coverBS6583:1985 ii BSI 07-1999 Foreword This British Standard has been prepared under the direction of the Refrigeration, Heating and Air Conditioning Standards Committee in response to requests from industry. The initial draft was prepared by the Heating, Ventilating and Ai
10、r Conditioning Manufacturers Association and has taken account of the work of the Air Conditioning and Refrigeration Institute of America. It has been assumed in the drafting of this British Standard that the execution of its provisions is entrusted to appropriately qualified and experienced people.
11、 A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises
12、 a front cover, an inside front cover, pages i and ii, pages1 to 10, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS6583:1985 BSI 07-1999 1
13、Section 1. General 0 Introduction The basic component of an air handling unit is the fan section, comprising a fan or fans installed inside a cabinet. It is the characteristics of the fan section, and not the fan alone, that are used as the basis of assessment when rating the volumetric performance
14、of the unit. The great majority of air handling units incorporate a heat exchanger, either immediately upstream or downstream of the fan section. Depending on the proximity of the coil, its location can modify the fan performance. The test unit consequently has to comprise at least a coil section, w
15、ith coil, in addition to the fan section. The measured pressure/volume characteristics of the test unit are corrected to arrive at the rated performance of the fan section alone. This rated performance therefore takes into account not only the entry losses associated with mounting a fan in a cabinet
16、, but also the effect introduced by a coil mounted in close proximity. Separate series of tests are necessary for upstream and downstream coil locations, to derive fan section performance ratings for draw through and blow through units respectively. This is important because blow through units, by v
17、irtue of their fans discharging into a plenum, incur expansion losses which can be significant. 1 Scope This British Standard describes methods for volumetric testing for rating of fan sections in central station air handling units. It specifies how fan section test data may be extrapolated to cover
18、: a) fan sections that are geometrically similar in all respects to the one tested; b) fan sections where the components and air passages, but not the fans, are geometrically similar. Appendix A provides a guide to the volumetric and thermal rating of complete air handling units. NOTEThe titles of t
19、he publications referred to in this standard are listed on the inside back cover. 2 Definitions For the purposes of this British Standard the following definitions apply: 2.1 central station air handling unit a factory-made encased assembly that consists of a fan or fans and other necessary equipmen
20、t to perform one or more of the functions of circulating, cleaning, heating, cooling, humidifying, dehumidifying, and mixing of air, but that does not include a direct source of heating or cooling. The unit is capable of use with duct work having a static resistance of more than100Pa 2.2 fan a rotar
21、y machine that maintains a continuous flow of air at a pressure ratio not normally exceeding1.3 2.3 impeller the rotating part of a fan that, by means of its blades, transfers energy to the air 2.4 fan casing those stationary parts of a fan that direct the flow of air from the fan inlet opening(s) t
22、o the fan outlet opening 2.5 fan section a cabinet, part of an air handling unit, in which a fan, or fans, is installed 2.6 coil section that part of an air handling unit in which the cooling or heating coil is installed 2.7 draw through central station air handling unit a unit with the coil section
23、 upstream of the supply fan 2.8 blow through central station air handling unit a unit with the coil section downstream of the supply fan 2.9 heating capacity the sensible heat output of the heat exchangers within the air handling unitBS6583:1985 2 BSI 07-1999 2.10 cooling capacity the total heat rem
24、oval capacity of the heat exchangers within the unit. It is the sum of the sensible and latent heat capacities of the heat exchangers 2.11 air handling capacity the quantity of standard air leaving the air handling unit against a specified pressure; this pressure is the static pressure external to t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS65831985METHODSFORVOLUMETRICTESTINGFORRATINGOFFANSECTIONSINCENTRALSTATIONAIRHANDLINGUNITSINCLUDINGGUIDANCEONRATING

链接地址:http://www.mydoc123.com/p-546133.html