《BS 6485-1999 PVC-covered conductors for overhead power lines《悬吊式动力线用聚氯乙烯覆盖导体》.pdf》由会员分享,可在线阅读,更多相关《BS 6485-1999 PVC-covered conductors for overhead power lines《悬吊式动力线用聚氯乙烯覆盖导体》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS 6485:1999 ICS 29.060.2
2、0; 29.240.20 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW PVC-covered conductors for overhead power linesBS 6485:1999 This British Standard, having been prepared under the direction of the Electrotechnical Sector Committee, was published under the authority of the Standards
3、 Committee and comes into effect on 15 February 1999 BSI 02-1999 First published April 1971 Second edition May 1990 Third edition February 1999 The following BSI references relate to the work on this standard: Committee reference GEL/20/2 Draft for comment 97/262300 DC ISBN 0 580 28254 6 Amendments
4、issued since publication Amd. No. Date Text affected Committees responsible for this British Standard The preparation of this British Standard was entrusted by Technical Committee GEL/20, Electric cables, to Subcommittee GEL/20/2, Mains cables 1 kV and above, upon which the following bodies were rep
5、resented: Association of Consulting Engineers British Approvals Service for Cables British Cable Makers Confederation British Plastics Federation ERA Technology Ltd. Electricity Association London Underground Ltd. UK Steel AssociationBS 6485:1999 BSI 02-1999 i Contents Page Committees responsible In
6、side front cover Foreword ii 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Conductor 2 5 PVC covering 2 6 Schedule of tests 2 7 Test conditions 2 8 Routine tests 2 9 Sample tests 3 10 Type test 3 Annex A (normative) Test methods 4 Annex B (normative) Particulars of PVC-covered condu
7、ctors 5 Table 1 Schedule of tests 2 Table 2 Spark test voltage values 2 Table B.1 PVC-covered stranded hard-drawn copper conductors (Based on BS 7884) 5 Table B.2 PVC-covered stranded hard-drawn copper alloy conductors (Based on BS 7884) 5 Table B.3 PVC-covered aluminium stranded conductors (Based o
8、n BS 215-1) 6 Table B.4 PVC-covered aluminium conductors, steel reinforced (Based on BS 215-2) 6 Table B.5 PVC-covered aluminium alloy stranded conductors (Based on BS 3242) 7ii BSI 02-1999 BS 6485:1999 Foreword This new edition of BS 6485 has been prepared by Subcommittee GEL/20/2 and supersedes BS
9、 6485:1990 which is withdrawn. This edition has updated references mainly due to the withdrawal of BS 125:1970 and BS 2755:1970 which have been replaced by BS 7884:1997. This new edition incorporates technical changes. It does not represent a full review or revision of the standard, which will be un
10、dertaken in due course. Annexes A and B are normative. It has been assumed in the preparation of this British Standard that the execution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been produced. This British Standard calls for the use
11、 of substances and/or procedures that may be injurious to health if adequate precautions are not taken. It refers only to technical suitability and does not absolve the user from legal obligations relating to health and safety at any stage. A British Standard does not purport to include all the nece
12、ssary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages
13、 1 to 7 and a back cover. BSI 02-1999 1 BS 6485:1999 1 Scope This British Standard specifies requirements for PVC-covered conductors for overhead power lines. Two types of PVC-covered conductor have been standardized by the designation of minimum thickness of covering as follows: a) Type 8: 0.8 mm;
14、b) Type 16: 1.6 mm. Type 8 is intended for use only where the operating voltage of the power lines does not exceed 650 V r.m.s. between any two conductors or 250 V r.m.s. between any conductor and earth. Under these operating conditions, it is suitable for: a) crossings of telecommunication lines to
15、 guard against contact; b) proximities to telecommunication lines to guard against contact; c) lines (particularly service lines) accessible from buildings. Type 16 is intended for use only where the operating voltage of the power line exceeds 650 V r.m.s between any two conductors or 250 V r.m.s. b
16、etween any conductor and earth, but does not normally exceed 11 kV r.m.s. between conductors or 6.6 kV r.m.s. between any conductor and earth. The earthing of the neutral point of the system through an arc-suppression coil is not precluded, if arrangements exist for clearing earth faults without und
17、ue delay. Under these operating conditions, type 16 is suitable for crossings of telecommunication lines and proximities to them. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this British Standard. For dat
18、ed references, subsequent amendments to, or revisions of, any of these publications do not apply. For undated references, the latest edition of the publication referred to applies. BS 215-1, Specification for aluminium conductors and aluminium conductors, steel-reinforced for overhead power transmis
19、sion Part 1: Aluminium stranded conductors. BS 215-2, Specification for aluminium conductors and aluminium conductors, steel-reinforced for overhead power transmission Part 2: Aluminium conductors, steel-reinforced. BS 3242, Specification for aluminium alloy stranded conductors for overhead power tr
20、ansmission. BS 4727-2, Glossary of electrotechnical, power, telecommunication, electronics, lighting and colour terms Part 2: Terms particular to power engineering Group 08: Electric cables. BS 5099, Specification for spark testing of electric cables. BS 7655-3.1, Specification for insulating and sh
21、eathing materials for cables Part 3: PVC insulating compounds Section 3.1: Harmonized types. BS 7884, Specification for copper and copper-cadmium stranded conductors for overhead electric traction and power transmission systems. BS EN 60811-1-1:1995, Insulating and sheathing materials of electric ca
22、bles Common test methods Part 1: General application Section 1: Measurement of thickness and overall dimensions. 3 Terms and definitions For the purposes of this British Standard, the definitions given in BS 4727-2:Group 08 apply, together with the following. 3.1 nominal value value by which a quant
23、ity is designated and which is often used in tables NOTE Usually, in this standard, nominal values give rise to values to be checked by measurements taking into account specified tolerances. 3.2 approximate value value which is only indicative NOTE Usually, in this standard, values described as “app
24、roximate” do not constitute requirements to be checked by measurements. 3.3 routine tests tests made by the manufacturer on each manufactured length of covered conductor to check that the whole of each length meets the specified requirements2 BSI 02-1999 BS 6485:1999 3.4 sample tests tests made by t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS64851999PVCCOVEREDCONDUCTORSFOROVERHEADPOWERLINES 悬吊 动力 聚氯乙烯 覆盖 导体 PDF

链接地址:http://www.mydoc123.com/p-546072.html