BS 6397-1983 Specification for scales and sizes for plotting frequency characteristics and polar diagrams《绘制频率特性和极坐标图用标度和尺寸规范》.pdf
《BS 6397-1983 Specification for scales and sizes for plotting frequency characteristics and polar diagrams《绘制频率特性和极坐标图用标度和尺寸规范》.pdf》由会员分享,可在线阅读,更多相关《BS 6397-1983 Specification for scales and sizes for plotting frequency characteristics and polar diagrams《绘制频率特性和极坐标图用标度和尺寸规范》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS6397:1983 IEC263:1982 Specification for Scales and sizes for plotting frequency characteristics and polar diagrams UDC 621.3.085.4:621.3.018.4:621.3.012.12BS6397:1983 This British Standard, having been prepared under the directionof the Electronic Equipment Standards Committee,was
2、 published underthe authority of the BoardofBSI and comes intoeffecton 29July1983 BSI 12-1999 The following BSI references relate to the work on this standard: Committee reference EEL/24 Draft for comment 82/32494 DC ISBN 0 580 13381 8 Committees responsible for this British Standard This British St
3、andard was published under the direction of the Electronic Equipment Standards Committee EEL/-. Its preparation was entrusted to Technical Committee EEL/24 upon which the following bodies were represented: British Radio and Electronic Equipment Manufacturers Association Department of Health and Soci
4、al Security Department of Industry(National Physical Laboratory) Institution of Electronic and Radio Engineers Post Office Royal National Institute for the Deaf Society of Hearing Aid Audiologists Limited Amendments issued since publication Amd. No. Date of issue CommentsBS6397:1983 BSI 12-1999 i Co
5、ntents Page Committees responsible Inside front cover National foreword ii Introduction 1 1 Scope 1 2 Logarithmic frequency scales 1 3 Polar level diagrams 1 Appendix A Examples of the requirements specified in this standard 2 Figure A.1 Example of ventilating noise spectrum with a scale proportions
6、uchthat the length of the abscissa corresponding to a frequencyratio of10:1isequal to the length of the ordinate correspondingto25dB 3 Figure A.2 Example of a microphone calibration curve showing sensitivitylevelS as a function of frequency f, with a scale proportion of10dBfor a frequency ratio10:1
7、4 Figure A.3 Example of loudspeaker response with a scale proportion of50dBfor a frequency ratio10:1 4 Figure A.4 Example of a polar diagram with a reference circle radius corresponding to50dB showing sound level at a distance of150m from anaircraft 5 Figure A.5 Example of a polar diagram with a ref
8、erence circle radius corresponding to25dB showing the directional response of a radial horn loudspeaker at8000Hz 6BS6397:1983 ii BSI 12-1999 National foreword This British Standard has been prepared under the direction of the Electronic Equipment Standards Committee. It is identical with IEC Publica
9、tion263:1982 “Scales and sizes for plotting frequency characteristics and polar diagrams” published by the International Electrotechnical Commission (IEC). Terminology and conventions. The text of the International Standard has been approved as suitable for publication as a British Standard without
10、deviation. Some terminology and certain conventions are not identical with those used in British Standards. Attention is drawn especially to the following. In Figure A.3 the comma has been used as a decimal marker. In BritishStandards it is current practice to use a full point on the baseline as the
11、decimal marker. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This doc
12、ument comprises a front cover, an inside front cover, pagesi andii, pages1 to6 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS6397:1983 BSI 12-1999 1 Introductio
13、n In order that a proper impression may be gained from a graph in which a response is plotted as a level(in decibels) against frequency on a logarithmic scale, it is important that the proportions of the scales be standardized. Otherwise, a spectrum or response curve can be made to appear unduly fla
14、t or unduly steep by compression or expansion of one of the scales. The ultimate interest is usually an output spectrum that results from the combination of an input spectrum with several individual response characteristics such as those of a microphone, amplifier, loudspeaker and perhaps a transmis
15、sion loss. Such characteristics may similarly be combined for instruments such as hearing aids, recorders and vibration measuring apparatus. The contribution of each element to the final result is more readily understood if each characteristic is plotted to scales having a standard proportion. For d
16、isplaying response-frequency characteristics, different ranges and orders of accuracy are needed. Thus, a range of10dB may suffice for the response of a standard microphone, but a range of more than60dB may be required for a filter. Although these requirements emphasize the need for different scale
17、proportions, the number of proportions should be kept at a minimum to facilitate comparisons. If identical scale sizes are used, curves on translucent paper may be laid over one another for easy comparison. Although graphs for publication may be reduced to fit the printed page, the use of a standard
18、 proportion makes it feasible to compare graphs from different publications by direct superposition of suitable enlargements. 1 Scope 1.1 This standard specifies standard proportions for the scales for plotting frequency characteristics and polar diagrams. 1.2 This standard does not apply to audiogr
19、ams. 2 Logarithmic frequency scales For graphs in which a level(in decibels) is plotted against frequency on a logarithmic scale, the scale proportions shall be those for which the length for a10:1frequency ratio is equal to the length for a level difference of10dB,25dB or50dB on the ordinate scale.
20、 3 Polar level diagrams 3.1 For polar plots in which a level, in decibels, is shown increasing outward along a radius on a linear scale, the maximum level should preferably be plotted on, or within5dB of, a reference circle whose radius corresponds to a difference in level of50dB. Alternatively, the
21、 maximum level should preferably be plotted on, or within2.5dB of, the reference circle whose radius corresponds to a difference in level of25dB. The tolerance limits on the radius of the reference circle correspond respectively to 0.5dB and 0.25dB. These requirements apply for whatever length is ch
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS63971983SPECIFICATIONFORSCALESANDSIZESFORPLOTTINGFREQUENCYCHARACTERISTICSANDPOLARDIAGRAMS 绘制 频率特性 标图

链接地址:http://www.mydoc123.com/p-546018.html