《BS 6200-3 18 3-1985 Sampling and analysis of iron steel and other ferrous metals - Methods of analysis - Determination of manganese - Ferromanganese and ferrosilicomanganese potent.pdf》由会员分享,可在线阅读,更多相关《BS 6200-3 18 3-1985 Sampling and analysis of iron steel and other ferrous metals - Methods of analysis - Determination of manganese - Ferromanganese and ferrosilicomanganese potent.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 6200-3.18.3: 1985 EN 24159:1989 ISO 4159:1978 Incorporating Amendment No.1 Sampling and analysis of iron, steel and other ferrous metals Part 3: Methods of analysis Section 3.18 Determination of manganese Subsection 3.18.3 Ferromanganese and ferrosilicomanganese: potentiometric m
2、ethod The European Standard EN24159:1989 has the status of a British Standard UDC 669.15-198:543.257.1:546.711BS6200-3.18.3:1985 This British Standard, having been prepared under the directionof the Iron and Steel Standards Committee, was published under the authority ofthe Board of BSI and comes in
3、toeffect on 28 February 1985 BSI 09-1999 The following BSI references relate to the work on this standard: Committee reference ISM/18 Draft for comment 77/79237 DC ISBN 0 580 14267 1 National foreword This Subsection of BS 6200 has been prepared under the direction of the Iron and Steel Standards Co
4、mmittee. It is identical with ISO 4159:1978 “Ferromanganese and ferrosilicomanganese Determination of manganese content Potentiometric method” published by the International Organization for Standardization (ISO) and supersedes method 3 for the determination of manganese in BSI Handbook No.19. In198
5、9 the European Committee for Standardization (CEN) accepted ISO4159:1978 as European Standard EN24159:1989. Terminology and conventions. The text of the International Standard has been approved as suitable for publication as a British Standard without deviation. Some terminology and certain conventi
6、ons are not identical with those used in British Standards; attention is drawn especially to the following. The comma has been used as a decimal marker. In British Standards it is current practice to use a full point on the baseline as the decimal marker. Wherever the words “International Standard”
7、appear, referring to this standard, they should be read as “British Standard”. Cross-reference. At present there is no corresponding British Standard for ISO3713 which is still at draft stage. Appropriate procedures from ISO3713 will be incorporated in BS6200-2 “Methods of sampling and sample prepar
8、ation” which will be published in due course. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligati
9、ons. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, theEN title page, pages 2 to 6, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amend
10、ment table on the inside front cover. Amendments issued since publication Amd. No. Date of issue Comments 7073 February 1992 Indicated by a sideline in the marginBS6200-3.18.3:1985 BSI 09-1999 i Contents Page National foreword Inside front cover Brief history 2 Text of EN24159 3 Publication referred
11、 to Inside back coverii blankEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 24159 May 1989 UDC 669.15-198:543.257.1:546.711 Descriptors: Iron and steel products, ferroalloys, ferromanganese, ferrosilicon, silico-manganese, chemical analysis, determination of content, manganese, potentiometric
12、method English version Ferromanganese and ferrosilicomanganese Determination of manganese content Potentiometric method (ISO 4159, 1st edition, 1978-12-15) Ferromanganse et ferro-silico-manganse Dosage du manganse Mthode potentiomtrique (ISO 4159,1re dition,1978-12-15) Bestimmung des Mangangehalt vo
13、n Ferromangan und Ferrosilicomangan Potentiometrisches Verfahren (ISO 4159,1. Ausgabe,1978-12-15) This European Standard was approved by CEN on1989-05-15. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the st
14、atus of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A
15、 version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN member are the national standards organizations of Austria, Belgium, Denmark, Finland, France, G
16、ermany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CEN European Committee for Standardization Comit Europen de Normalisation Europisches Komitee fr Normung Central Secretariat: rue de Stassart 36, B-1050 Brussels CEN 198
17、9 Copyright reserved to all CEN members Ref. No. EN 24159:1989 EEN24159:1989 BSI 09-1999 2 Brief history On the proposal of the Technical Committee ECISS/TC20 “Methods of chemical analysis” the Coordinating Commission (COCOR) of the European Committee for Iron and Steel Standardization (ECISS) decid
18、ed on1987-11-24/25 to submit the International Standard ISO4159:1978, Ferromanganese and ferrosilicomanganese Determination of manganese content Potentiometric method (ISO4159,1st edition,1978-12-15) to the Formal Vote. This European Standard was adopted by CEN on1988-11-26. According to the Common
19、CEN/CENELEC Rules, the following countries are bound to implement this European Standard: Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. Statement The text of the Internat
20、ional Standard ISO4159, edition1,1978-12-15 was approved by CEN as a European Standard without any modification. Contents Page Brief history 2 1 Scope and field of application 3 2 Reference 3 3 Principle 3 4 Reagents 3 5 Apparatus 4 6 Sample 4 7 Procedure 4 8 Expression of results 5 9 Reproducibilit
21、y 5 10 Test report 5EN24159:1989 BSI 09-1999 3 1 Scope and field of application This International Standard specifies a potentiometric method for the determination of the manganese content of ferromanganese and ferrosilicomanganese. The method is applicable to alloys containing from55 to95%(m/m) of
22、manganese. 2 Reference ISO 3713, Ferroalloys Sampling and preparation of samples General rules 1) . 3 Principle Dissolution of a test portion with hydrochloric, hydrofluoric and perchloric acids. Potentiometric determination (see note) of manganese with potassium permanganate in a pyrophosphoric med
23、ium at a controlled pH, according to the reaction: 4 Mn 2+ MnO 4 + 8 H + 15 (P 2 O 7 H 2 ) 2 F 5 Mn(P 2 O 7 H 2 ) 3 3+ 4 H 2 O NOTEThe method may be completed by any other electrometric method: amperometric titration, dead-stop, etc. 4 Reagents During the analysis, use only reagents of recognized an
24、alytical grade, and only distilled water or water of equivalent purity, except where otherwise specified. 4.1 Perchloric acid 2) , 1,61g/ml. 4.2 Hydrofluoric acid, 1,14g/ml. 4.3 Hydrochloric acid, 1,19g/ml. 4.4 Hydrochloric acid, 1,19g/ml, diluted1+2. 4.5 Hydrochloric acid, 1,19g/ml, diluted1+4. 4.6
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS620031831985SAMPLINGANDANALYSISOFIRONSTEELANDOTHERFERROUSMETALSMETHODSOFANALYSISDETERMINATIONOFMANGANESEFERROMANGANESEANDFERROSILICOMANGANESEPOTENTPDF

链接地址:http://www.mydoc123.com/p-545828.html