《BS 6200-3 16 2-1986 Sampling and analysis of iron steel and other ferrous metals - Methods of analysis - Determination of lead - Steel spectrophotometric method《铁、钢和其他铁金属的抽样和分析 分析方.pdf》由会员分享,可在线阅读,更多相关《BS 6200-3 16 2-1986 Sampling and analysis of iron steel and other ferrous metals - Methods of analysis - Determination of lead - Steel spectrophotometric method《铁、钢和其他铁金属的抽样和分析 分析方.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 6200-3.16.2: 1986 Sampling and analysis of iron, steel and other ferrous metals Part 3: Methods of analysis Section 3.16 Determination of lead Subsection 3.16.2 Steel: spectrophotometric method UDC 669.1:543.42.062:546.815BS6200-3.16.2:1986 This British Standard, having been prep
2、ared under the directionof the Iron and Steel Standards Committee, was published under the authority ofthe Board of BSI and comes intoeffect on 30 September 1986 BSI 09-1999 The following BSI references relate to the work on this standard: Committee reference ISM/18 Draft for comment 85/37324 DC ISB
3、N 0 580 15283 9 Amendments issued since publication Amd. No. Date of issue CommentsBS6200-3.16.2:1986 BSI 09-1999 i Contents Page Foreword ii 1 Scope 1 2 Principle 1 3 Reagents 1 4 Apparatus 1 5 Sampling 1 6 Procedure 1 7 Calculation and expression of results 2 8 Test report 3 Table 1 Precision data
4、 3 Publications referred to Inside back coverBS6200-3.16.2:1986 ii BSI 09-1999 Foreword This Subsection of BS 6200 has been prepared under the direction of the Iron and Steel Standards Committee. It supersedes method2 for the determination of lead in BSI Handbook No.19, to which it is technically eq
5、uivalent. BS 6200 is a multipart British Standard covering all aspects of the sampling and analysis of iron, steel and other ferrous metals. A list of contents, together with general information, will be given in Part1, to be published in due course. A British Standard does not purport to include al
6、l the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andi
7、i, pages1 to 4, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS6200-3.16.2:1986 BSI 09-1999 1 1 Scope This Subsection of BS 6200 describes a
8、 spectrophotometric method for the determination of lead in steel. The method is applicable to lead contents from0.05% m/m to0.5% m/m. NOTEThe titles of the publications referred to in this Subsection of BS6200 are listed on the inside back cover. 2 Principle Lead is converted to its dithizone compl
9、ex in ammoniacal citrate-cyanide solution and extracted into chloroform. The determination is completed spectrophotometrically. 3 Reagents During the analysis, use only reagents of recognized analytical reagent grade and only distilled water or water of equivalent purity. Use only reagents which are
10、 known to give a very low lead blank. 3.1 Ammonia solution, density ( ) 0.91 g/mL, diluted1 + 3. 3.2 Ammonia solution, 0.91g/mL, diluted 1 + 3. 3.3 Chloroform 3.4 Citric acid, 500 g/L solution. Dissolve 500 g of citric acid (H 8 C 6 O 7 .H 2 O) in water, dilute to1L and mix. 3.5 Dithizone, 0.05 g/L
11、solution. Dissolve 0.005 g of dithizone in chloroform, dilute to100mL with chloroform and mix. 3.6 Hydrochloric acid, 1.16g/mL to1.19g/mL. 3.7 Hydroxylammonium chloride, 100g/L solution. Dissolve 10g of hydroxylammonium chloride in water, dilute to100mL and mix. 3.8 Iron, of high purity, free from l
12、ead. 3.9 Lead, standard solution, corresponding to0.5mg lead per mL. Dissolve 0.500 g of high purity lead in20mL of nitric acid (3.11). Boil to remove nitrous fumes and cool. Transfer to a1L volumetric flask, dilute to the mark and mix. 3.10 Nitric acid, 1.42g/mL. 3.11 Nitric acid, 1.42g/mL, diluted
13、 1 +4. 3.12 Perchloric acid, 1.54g/mL. 3.13 Potassium cyanide, 100g/L solution. Dissolve 100g of potassium cyanide in water, dilute to1L and mix. 3.14 Potassium cyanide, 5 g/L solution. Dissolve 5 g of potassium cyanide in water, dilute to1L and mix. 3.15 Thymol blue, 0.4g/L solution. Dissolve 0.1 g
14、 of thymol blue by warming with4mL of sodium hydroxide solution (3.16) and5mL of ethanol. Add50mL of ethanol, dilute to250mL with water and mix. 3.16 Sodium hydroxide, 2 g/L. Dissolve 0.2 g of sodium hydroxide in water, dilute to100mL and mix. Prepare and store this solution in polyethylene containe
15、rs. 4 Apparatus Use ordinary laboratory apparatus. Use only volumetric glassware in accordance with class A of BS846, BS1583 or BS1792, as appropriate. Use also the following. 4.1 Spectrophotometer 4.2 Cells, having an optical path length of1cm. 5 Sampling Sampling shall be carried out in accordance
16、 with BS1837. NOTEBS 6200-2 “Methods of sampling and sample preparation”, which will supersede BS1837, is currently in preparation. On its publication, this Subsection will be amended to include a requirement to sample in accordance with BS6200-2. 6 Procedure 6.1 Test portion Weigh, to the nearest 0
17、.001g, a test portion of0.5g. 6.2 Blank test In parallel with the determination and following the same procedure, carry out a blank test using the same quantities of all reagents. NOTEA typical blank value for this method is equivalent to0.02% m/m lead. 6.3 Determination Place the test portion in a2
18、50mL conical beaker. Add10mL of hydrochloric acid (3.6), 1mL of nitric acid (3.10), and heat gently until solvent action ceases. Add 10 mL of perchloric acid (3.12), evaporate to fuming and continue fuming until any chromium present is fully oxidized. Add1mL of hydrochloric acid (3.6) dropwise, then
19、 reheat to fuming until any remaining chromium is again fully oxidized. If necessary, repeat the treatment with hydrochloric acid and fuming up to four times to remove residual chromium.BS6200-3.16.2:1986 2 BSI 09-1999 Cool, transfer to a250mL volumetric flask, dilute to the mark and mix. Transfer a
20、5mL aliquot to a125mL conical beaker. NOTEThis and all subsequent reagent additions should be made by means of a safety pipette or burette. Add 5 mL of hydroxylammonium chloride solution(3.7), stand the beaker in a boiling water bath for5min, then cool. Add 1 mL of citric acid solution (3.4) and a f
21、ew drops of thymol blue indicator (3.15). Then add ammonia solution (3.1) until the colour of the indicator changes to green-blue. Add a further5mL of ammonia solution (3.1) and cool. Transfer the solution to a100mL separating funnel marked at50mL and rinse with water. Add5mL of potassium cyanide so
22、lution (3.13) and dilute to the mark. From a burette, add 5.0mL of chloroform (3.3) and then add dithizone solution (3.5) from a burette,1.0mL at a time, shaking between each addition, until an excess of dithizone is indicated by the colour of the chloroform layer changing to purple-blue. Add2.0mL o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS620031621986SAMPLINGANDANALYSISOFIRONSTEELANDOTHERFERROUSMETALSMETHODSOFANALYSISDETERMINATIONOFLEADSTEELSPECTROPHOTOMETRICMETHOD

链接地址:http://www.mydoc123.com/p-545823.html