BS 6195-2006 Electric cables - Rubber or silicone rubber insulated flexible cables and cords for coil end leads《电缆 线圈端导线用橡胶或硅橡胶绝缘软电缆及电线》.pdf
《BS 6195-2006 Electric cables - Rubber or silicone rubber insulated flexible cables and cords for coil end leads《电缆 线圈端导线用橡胶或硅橡胶绝缘软电缆及电线》.pdf》由会员分享,可在线阅读,更多相关《BS 6195-2006 Electric cables - Rubber or silicone rubber insulated flexible cables and cords for coil end leads《电缆 线圈端导线用橡胶或硅橡胶绝缘软电缆及电线》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、BS 6195:2006Electric cables Rubber or silicone rubber insulated flexible cables and cords for coil end leadsICS 29.060.20NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDPublishing and copyright informationThe BSI copyright notice displayed in this document indic
2、ates when the document was last issued. BSI July 2006ISBN 0 580 48588 9The following BSI references relate to the work on this standard:Committee reference GEL/20/17Draft for comment 05/30138596DCPublication historyFirst published, December 1969Second edition, May 1993Third edition, July 2006Amendme
3、nts issued since publicationAmd. no. Date Text affectedBS 6195:2006 BSI 2006 iBS 6195:2006ContentsForeword ii1 Scope 12 Normative references 13 Terms and definitions 24 Voltage categories 25 Conductors 26 Insulation 37 Identification 38 Cable marking 49 Routine tests for finished cables 410 Sample t
4、ests for finished cables 511 Type tests for finished cables 6Bibliography 16List of figuresFigure C.1 Method of measuring the surface resistivity of semicon-ducting tape 11List of tablesTable 1 Voltage categories 2Table 2 Dimensional requirements for cables 6Table B.1 Schedule of tests 9Table H.1 Di
5、ameters of mandrels for bending in different tests 13Table H.2 Test voltages 13Summary of pagesThis document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 16, an inside back cover and a back cover.ii BSI 2006BS 6195:2006ForewordPublishing informationThis British Standard
6、 was published by BSI and came into effect on 15 July 2006. It was prepared by Subcommittee GEL/20/17, Low voltage cables, under the authority of Technical Committee GEL/20, Electric cables.SupersessionThis British Standard supersedes BS 6195:1993, which is withdrawn.Information about this documentT
7、his new edition of BS 6195 retains requirements in respect of cable types 4 and 5 only. Requirements for other types have been withdrawn as they are no longer considered to be maket relevant.The other principal changes introduced in this edition are to call up CENELEC harmonized test methods in plac
8、e of earlier national methods.Product certification/inspection/testingUsers of this British Standard are advised to consider the desirability of third-party certification/inspection/testing of product conformity with this British Standard. Users seeking assitance in identifying appropriate conformit
9、y assessment bodies or schemes may ask BSI to forward their enquires to the relevant association.WARNINGThis British Standard calls for the use of substances and/or procedures that can be injurious to health if adequate precautions are not taken. It refers only to technical suitability and does not
10、absolve the user from legal obligations relating to health and safety at any stage.Presentational conventionsThe provisions of this standard are presented in roman (i.e. upright) type. Its requirements are expressed in sentences in which the principal auxiliary verb is “shall”.Commentary, explanatio
11、n and general informative material is presented in smaller italic type, and does not constitute a normative element.Contractual and legal considerationsThis publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Complianc
12、e with a British Standard cannot confer immunity from legal obligations. BSI 2006 1BS 6195:20061 ScopeThis British Standard specifies requirements for various types of insulation, voltage categories and dimensions for a standard range of insulated flexible cables and flexible cords (commonly known a
13、s “coil end leads”), that are intended to be connected directly and permanently to a coil winding or other component of electrical apparatus.The types of cable specified in this standard are as follows:Type 4 cable, voltage categories A, C, D, E and F, for a designated temperature of 90 C (flame ret
14、ardant, rubber insulated coil leads);Type 5 cable, voltage categories A, C, D, E and F, for a designated temperature of 180 C (180 C silicone rubber insulated coil leads).NOTE A guide to the use of the cables specified in this British Standard is given in Annex A. A summary of the tests applicable t
15、o the cables is given in Annex B.2 Normative referencesThe following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) app
16、lies.BS 4727-2: Group 08, Glossary of electrotechnical, power, telecommunication, electronics, lighting and colour terms Part 2: Terms particular to power engineering Group 08: Electric cables.BS 5099 Electric cables Voltage levels for spark testing.BS 5629-3:1979 Insulating varnishes containing sol
17、vent Part 3: Method for specifying requirements for individual materialsBS 7655 Specification for insulating and sheathing materials for cables Part 1: Cross-linked elastomeric insulating compounds Section 1.5 Flame retardant composites BS EN 50356, Method for spark testing of cables.BS EN 50363-1,
18、Insulating, sheathing and covering materials for low voltage energy cables Part 1: Cross-linked elastomeric insulating compounds BS EN 60228, Conductors of electric cablesBS EN 60332-1-2, Tests on electric and optical fibre cables under fire conditions Part 12: Test for vertical flame propagation fo
19、r a single insulated wire or cable Procedure for 1 kW pre-mixed flameBS EN 60811-1-1, Insulating and sheathing materials of electric cables Common test methods Part 1-1: General application Measurement of thickness and overall dimensions Tests for determining the mechanical properties.BS EN 60811-1-
20、2, Insulating and sheathing materials of electric cables Common test methods Part 1-2: General application Thermal ageing methodsPD 2379, Register of colours of manufacturers identification threads for electric cables and cords.BS 6195:20062 BSI 20063 Terms and definitionsFor the purposes of this Br
21、itish Standard the definitions given in BS 4727-2: Group 08 apply, together with the following.3.1 values3.1.1 approximate valuevalue which is only indicativeNOTE Values described as “approximate” do not constitute requirements to be checked by measurement.3.1.2 nominal valuevalue by which a quantit
22、y is designatedNOTE Nominal values usually give rise to values to be checked by measurements taking into account specified tolerances.4 Voltage categoriesThe cables shall be divided into the voltage categories listed in Table 1, which are defined by the appropriate maximum voltage between conductors
23、, or between conductor and earth, to which the cable is liable to be subjected during a 1 min test of the equipment to which it is connected.5 Conductors5.1 Type The conductors shall conform to BS EN 60228, class 5. The conductors shall be circular, tinned annealed copper. NOTE For these cables tinn
24、ed conductors are not required to meet a test for tinning.5.2 TapesIf required, a tape or tapes shall be applied over the conductor.In the case of voltage categories E and F, if a tape is used it shall be a semi-conducting tape consisting of a textile fabric proofed with a suitable semi-conducting c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS61952006ELECTRICCABLESRUBBERORSILICONERUBBERINSULATEDFLEXIBLECABLESANDCORDSFORCOILENDLEADS 电缆 线圈 导线

链接地址:http://www.mydoc123.com/p-545799.html