BS 6004-2012 Electric cables PVC insulated and PVC sheathed cables for voltages up to and including 300 500 V for electric power and lighting《电缆 电力、照明和内部布线用电压不超过300 500 V的聚氯乙烯(PVC).pdf
《BS 6004-2012 Electric cables PVC insulated and PVC sheathed cables for voltages up to and including 300 500 V for electric power and lighting《电缆 电力、照明和内部布线用电压不超过300 500 V的聚氯乙烯(PVC).pdf》由会员分享,可在线阅读,更多相关《BS 6004-2012 Electric cables PVC insulated and PVC sheathed cables for voltages up to and including 300 500 V for electric power and lighting《电缆 电力、照明和内部布线用电压不超过300 500 V的聚氯乙烯(PVC).pdf(34页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS 6004:2012Electric cables PVCinsulated and PVC sheathedcables for voltages up toand including 300/500 V, forelectric power and lightingPublishing and copyright informationThe B
2、SI copyright notice displayed in this document indicates when the documentwas last issued. The British Standards Institution 2012Published by BSI Standards Limited 2012ISBN 978 0 580 75844 7ICS 29.060.20The following BSI references relate to the work on this standard:Committee reference GEL/20/17Dra
3、ft for comment 12/30248753 DCPublication historyFirst published August 1969Second edition, January 1976Third edition, May 1984Fourth edition, October 1990Fifth edition, November 1991Sixth edition, December 2000Seventh (present) edition, September 2012Amendments issued since publicationDate Text affe
4、ctedBS 6004:2012 BRITISH STANDARDContents1 Scope 12 Normative references 13 Terms and definitions 24 Rated voltage 35 Construction 36 Conductors 37 Insulation 38 Identification of cores 49 Multi-core circular cables 510 Sheath 511 Cable marking and additional information 612 Schedule of tests 713 Te
5、st conditions 714 Routine tests 815 Sample tests 916 Type tests 10AnnexesAnnex A (informative) Coding cross references 17Annex B (informative) Traditional UK cables transferred to BS EN 50525 18Annex C (informative) Guide to use 20Annex D (normative) Compatibility test 23Annex E (normative) Method o
6、f test for voltage withstand 24Annex F (informative) Notes on type tests 24List of figuresFigure1Anexample of the marking as used on the outer sheath of thecable 7List of tablesTable 1 Maximum permitted voltages against rated voltage of cable 3Table 2 Schedule of tests 8Table 3 PVC insulated, PVC sh
7、eathed cable, 300/500 V, single core 6181Y, flattwin 6192Y and flat 3-core 6193Y 12Table 4 PVC insulated, PVC sheathed cable with circuit protective conductor(CPC), 300/500 V, single core 6241Y, flat twin 6242Y and flat 3-core 6243Y 13Table 5 PVC insulated, PVC sheathed cable with or without circuit
8、 protectiveconductor (CPC), 300/500 V, single core 6241Y and flat twin (6192Y and 6242Y)(alternative conductor versions) 14Table 6 Ordinary duty low temperature PVC insulated and PVC sheathedflexible cable, flat twin 3192A, circular 2-core 3182A, 3-core 3183A, 4-core 3184Aand 5-core 3185A, 300/500 V
9、 15Table A.1 UK and harmonized CENELEC coding cross references: BS 6004 17Table A.2 UK and harmonized CENELEC coding cross references: BS 7919 17Table B.1 Standard PVC conduit cable: formerly in BS 6004 18Table B.2 Standard PVC flexible cable: formerly in BS 6500 19Table C.1 Construction details, me
10、thod of installation and temperaturefor Table 3 to Table 5 21Table C.2 Construction details, method of installation and temperaturefor Table 6 22Table C.3 Guide to use 23Table D.1 Compatibility requirements 23Summary of pagesThis document comprises a front cover, an inside front cover, pages i to iv
11、,pages 1 to 26, an inside back cover and a back cover.BRITISH STANDARD BS 6004:2012 The British Standards Institution 2012 iForewordPublishing informationThis British Standard is published by BSI Standards Limited, under licence fromThe British Standards Institution, and comes into effect on 1 Janua
12、ry 2013. It wasprepared by Subcommittee GEL/20/17, Low voltage cables, under the authorityof Technical Committee GEL/20, Electric cables. A list of organizationsrepresented on this committee can be obtained on request to its secretary.SupersessionThis British Standard supersedes BS 6004:2000 (incorp
13、orating AmendmentsNos. 1 and 2) and partially supersedes BS 7919:2001 (incorporating AmendmentsNos. 1, 2 and 3), which are to be withdrawn on 31 December 2012.Relationship with other publicationsThe new edition takes account of: BS EN 60228 (replacing BS 6360) on conductors; BS EN 50363-3 (replacing
14、 BS 7655-3.1) on materials; BS EN 50395 (replacing Annex C of BS 6004:2000) on electrical tests; BS EN 50396 (replacing Annex D of BS 6004:2000) on thicknessmeasurement; BS EN 60332-1-2 (replacing BS EN 50265-2-1); BS EN 62230 (replacing BS EN 50356) on spark testing.Information about this documentI
15、n the preparation of BS 6004, GEL/20/17 has requested that references to otherstandards for which the committee is responsible are undated, even if referringto a specific clause. It is the committees intention not to amend thefundamentals (e.g. clause numbers, material type designation) in any of th
16、esestandards and so the latest edition applies.This is a full revision of the standard, which has been revised due to theconversion of CENELEC Harmonization Documents HD 21 and HD 22 toBS EN 50525 (all parts). The previous edition of BS 6004 included a number ofcable types that were harmonized and m
17、arked with CENELEC harmonized codedesignations. The following cables are now included in BS EN 50525 (all parts)and withdrawn from BS 6004, which now only contains national types: PVC insulated, non-sheathed general purpose cable, single core (H07V-U,H07V-R and H07V-K) 450/750 V; PVC insulated, non-
18、sheathed cable for internal wiring, single core (H05V-U,H05V-R and H05V-K) 300/500 V; PVC insulated, non-sheathed, heat-resisting cable, for internal wiring, singlecore (H05V2-U, H05V2-R and H05V2-K) 300/500 V; PVC insulated, non-sheathed, heat-resisting cable, for internal wiring, singlecore (H07V2
19、-U, H07V2-R and H07V2-K) 450/750 V; oil resisting PVC sheathed, screened cables, having between 2 and 60 cores(H05VVC4V5-K) 300/500 V.The following cables have also been withdrawn from BS 6004 followingwithdrawal by CENELEC: PVC insulated, non-sheathed cable, single core for installation at lowtempe
20、ratures (H07V3-U, H07V3-R and H07V3-K) 450/750 V.BRITISH STANDARDBS 6004:2012ii The British Standards Institution 2012The content of BS 6004 has been aligned with that found in BS EN 50525, whereappropriate.This edition of BS 6004 includes ordinary duty low temperature PVC insulatedand sheathed flex
21、ible cable, parallel twin, circular twin, 3-core, 4-core and5-core, 300/500 V from BS 7919:2001, Table 441), which have the traditionalUnited Kingdom Cable Codes of 3192A, 3182A, 3183A, 3184A and 3185A andare normally used for reduced voltage applications on building sites.Annex A has been included
22、to provide further clarification on whereinformation from BS 6004:2000 and BS 7919:2001 has been moved to in thisedition of BS 6004 and BS EN 50525-2-31. Annex B has been included to provideclarification on which cables have been transferred to BS EN 50525 (all parts).The importance of the relations
23、hip between the traditional United KingdomCable Code (formerly known as the CMA coding) and its equivalent harmonizedCENELEC code designations is emphasized. This additional information helps theuser to choose the appropriate cable.Product certification/inspection/testing. Users of this British Stan
24、dard are advisedto consider the desirability of third-party certification/inspection/testing ofproduct conformity with this British Standard. Users seeking assistance inidentifying appropriate conformity assessment bodies or schemes may ask BSI toforward their enquiries to the relevant association.H
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS60042012ELECTRICCABLESPVCINSULATEDANDPVCSHEATHEDCABLESFORVOLTAGESUPTOANDINCLUDING300500VFORELECTRICPOWERANDLIGHTING

链接地址:http://www.mydoc123.com/p-545563.html