BS 572-1985 Specification for interchangeable conical ground glass joints《互换式锥形毛玻璃接头规范》.pdf
《BS 572-1985 Specification for interchangeable conical ground glass joints《互换式锥形毛玻璃接头规范》.pdf》由会员分享,可在线阅读,更多相关《BS 572-1985 Specification for interchangeable conical ground glass joints《互换式锥形毛玻璃接头规范》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、BS 572 : 1985 UDC 542.231.7 : 666.285.6 British Standards Institution. No patt of this publication may be photocopied or otherwise (epmduced without the prior permission in writing of BSI British Standard Specification for Interchangeable conical ground glass joints Assemblages coniques rods interch
2、angeables en verre - Spcifications Austauschbare Kegelschliffverbindungen Brit ish Standards I nsti tu ti on _- - BSI BSM572 85 So 1b24bb9 0119427 8 M Foreword This British Standard has been prepared under the direction of the Laboratory Apparatus Standards Committee. It is a revision of BS 572 : 19
3、60, which is withdrawn. The technical requirements are the same as those of IS0 383-1 976 Laboratory glassware - Interchangeable conical ground joints published by the International Organization for Standardization (ISO), but the text has been editorially rearranged to improve clarity. However, a ma
4、rking clause similar to that in BS 572 : 1960 has been retained in this revision, The purpose of this standard is to ensure interchangeability between standard conical ground glass joints, irrespective of where they are manufactured. In order to achieve interchangeability, it is necessary that each
5、of the following requirements be adequately specified, including appropriate tolerances: (a) taper; (b) large end diameter; (c) length of ground zone; (d) surface finish. The nominal dimensions listed in table 1 are based on the series of joints already widely used in many countries; in particular,
6、the series of large end diameters represents the nearest acceptable compromise to the R 40/3 series of preferred numbers recommended in BS 2045. From the practical point of view, and especially because of the difficulty of carrying out precise measurements on the ground portions of the finished join
7、ts, it is desirable to apply a gauging system that allows rapid checking of the essential dimensions. The definition of these dimensions in clause 5 is an integral part of this standard, but the system of gauging described in appendix A, while it has been proved in practice to be fully satisfactory,
8、 is not the only one that can be applied for the purpose. The leakage test described in appendix B is that commonly used for testing joints, but its inclusion in this standard is not intended to preclude the use of other tests which may be found more convenient for particular purposes, Attention is
9、specifically drawn to the method of pneumatic gauging“. The principal differences from the 1960 edition of this standard are: (a) the elimination of the former BS designation, permitted as an alternative; (b) the inclusion of a further series of joints based on a value of eight for the constant for
10、the calculation of the length of the ground zone (see clause 4); (c) two sizes of joints have been deleted and five have been added, in particular three larger sizes in the series based on a value of six for the constant for the calculation of the length of the ground zone; (d) the gauging system (s
11、ee appendix A) is now a recommended procedure instead of the only one allowed. Compliance with a British Standard does not of itself confer immunity from legal obligations. *This method is described by Smith, I.C.P., Pneumatic gauging applied to standard ground glass joints, Laboratory Practice, 195
12、8, 7, (3). - O a l ! I I 1 a -1 BSI BS*572 85 I Jb24bb 0339428 T I BS 572 : 1985 Contents Foreword Committees responsible Page Inside front cover Back cover Specification 1 Scope 2 2 Designation 2 3 Large end diameter 2 4 Length of ground zone 2 5 Tolerances on diameter and length 2 6 Taper 4 7 Surf
13、ace finish 4 8 Marking 4 Appendices A Suitable gauging system for diameter and length B Leakage test for conical joints 6 of conical joints 5 Tables 1 Nominal dimensions of conical joints 2 Dimensions and tolerances of the dimensional frame for checking dimensions of sockets and cones 3 2 Figures 1
14、Dimensions of conical ground glass joints 4 2 Gauge for sockets 5 3 Gauge for cones 5 4 Suitable apparatus for leakage test on conical joints 6 r I BS 572 : 1985 Specification 1 Scope This British Standard specifies the essential geometric requirements for interchangeability in relation to four seri
15、es of conical ground glass joints for laboratory use. NOTE 1. The term cone is used in this British Standard for the part which is inserted and the term socket for the part into which the cone is inserted. NOTE 2. The titles of the publications referred to in this standard are listed on the inside b
16、ack cover. 2 Designation (see table 1) Joints shall be designated by two numbers, separated by an oblique or horizontal stroke, as follows: (a) the rounded value of the large end diameter of the joint in millimetres; (b) the nominal length of the ground zone in millimetres. 19 26 NOTE. Examples of d
17、esignation: 19/26 or -. 3 Large end diameter The following series of nominal diameters of the large end of the ground zone shall be adopted: 5, 7.5, IO, 12.5, 14.5, 18.8, 21.5, 24, 29.2,34.5, 40, 45, 50,60, 71,85, 100 mm. 4 Length of ground zone The length of the ground zone I, in millimetres, (see
18、figure 1) shall be calculated using the following equation and rounded to the nearest whole number /=kT k is a constant = 2,4,6 or 8 for the four series; d is the large end diameter (in mm). where NOTE. The four series of joints listed in table 1 are obtained by using the values, 2, 4,6 and 8 for th
19、e constant k. Joints based on the value 6 for the constant are the preferred series. 5 Tolerances on diameter and length The diameter and length of the ground zone shall be such that, when it is placed with its axis in the plane of the dimensional frame shown in figure 1, it fits in.such a way that
20、the upper and lower edges of the ground zone fall within the zonesof height hl and h, respectively, the values of ci, I, h, and h2 for any particular joint size being taken from table 2. NOTE. For special purposes, the ground zone may extend beyond the outer limit of zoneh, ,provided that it also ex
21、tends into zone h, . A system of gauging suitable for determining whether joints fall within these limits is described in appendix A. Table 1. Nominal dimensions of conical joints Designation k=2 1919 2411 O 2911 1 3411 2 4011 3 4511 3 5011 4 k=4 519 711 1 10113 12/14 1411 5 1911 7 21/19 24/20 29/22
22、 34/23 k=6 (preferred series) 511 3 711 6 10119 12/21 . 14/23 19/26 21/28 24/29 29/32 34/35 40138 45/40 50142 60146 7 1 I51 85155 100160 k=8 511 8 7/22 10125 12/28 14/30 19/35 21 137 24139 29/43 34/47 Nominal diameter of large end of ground zone mm 18.8 24.0 29.2 34.5 40.0 45.0 50.0 5.0 7.5 10.0 12.
23、5 14.5 18.8 21.5 24.0 29.2 34.5 5.0 7.5 10.0 12.5 14.5 18.8 21.5 24.0 29.2 34.5 40.0 45.0 50.0 60.0 71 .O 85.0 100.0 5.0 7.5 10.0 12.5 14.5 18.8 21.5 24.0 29.2 34.5 Nominal length of ground zone measured axially mm 9 10 11 12 13 13 14 9 11 13 14 15 17 19 20 22 23 13 16 19 21 23 26 28 29 32 35 38 40
24、42 46 51 55 60 18 22 25 28 30 35 37 39 43 47 _ . :. BS 572 : 1985 Table 2. Dimensions and tolerances of the dimensional frame for checking dimensions of sockefs and cones (See clause 6 and figures 1,2 and 3) Designation Diameter, d, -I- 1919 24/10 2911 1 3411 2 4011 3 45/13 5011 4 18.9 24.1 29.3 34.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS5721985SPECIFICATIONFORINTERCHANGEABLECONICALGROUNDGLASSJOINTS 互换 锥形 毛玻璃 接头 规范 PDF

链接地址:http://www.mydoc123.com/p-545328.html