BS 5611-1978 Application guide for on-load tap-changers《负载分接头切换开关应用指南》.pdf
《BS 5611-1978 Application guide for on-load tap-changers《负载分接头切换开关应用指南》.pdf》由会员分享,可在线阅读,更多相关《BS 5611-1978 Application guide for on-load tap-changers《负载分接头切换开关应用指南》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS5611:1978 IEC542:1976 Application guide for on-load tap-changers UDC 621.314.214.332BS5611:1978 This BritishStandard, having been prepared under the directionof the Power Electrical Engineering Standards Committee, waspublished underthe authorityofthe Executive Boardon 31October19
2、78 BSI 12-1999 The following BSI references relate to the work on this standard: Committee reference PEL/113 Draft for comment 77/22263 DC ISBN 0 580 10383 8 Cooperating organizations The Power Electrical Engineering Standards Committee, under whose direction this BritishStandard was prepared, consi
3、sts of representatives from the following Government departments and scientific and industrial organizations: Associated Offices Technical Committee Association of Short Circuit Testing Authorities British Electrical and Allied Manufacturers Association(BEAMA) British Railways Board* British Steel C
4、orporation Department of Energy Electricity Electrical Contractors Association Electrical Contractors Association of Scotland Electrical Research Association Electricity Supply Industry in England and Wales* Engineering Equipment Users Association* Institution of Electrical Engineers Ministry of Def
5、ence National Coal Board* Trades Union Congress The organizations marked with an asterisk in the above list, together with the following, were directly represented on the committee entrusted with the preparation of this BritishStandard: Association of Consulting Engineers Engineer Surveyors Associat
6、ion London Transport Executive The Transmission these are as listed below: A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer
7、 immunity from legal obligations. International Standard Corresponding BritishStandard IEC76 BS171 Power transformers IEC76-1:1976 BS171-1:1978 General (Identical) IEC76-4:1976 BS171-4:1978 Specification for tappings and connections (Identical) IEC76-5:1976 BS171-5:1978 Specification for ability to
8、withstand short circuit (Identical) IEC214:1976 BS4571:1978 Specification for on-load tap changers (Identical) IEC354:1972 CP1010:1975 Loading guide for oil-immersed transformers (Technically equivalent) Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pag
9、es1 to4, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS5611:1978 BSI 12-1999 1 1 Scope This application guide is intended to assist in the
10、selection of suitable on-load tap-changers for use in conjunction with the tapped windings of transformers or reactors which, in the following text, are referred to as transformers. As in the second edition of IEC Publication214, On-load Tap-changersrevision of Publication214(1966), the designation
11、“on-load tap-changer” is shortened to “tap-changer” in the remainder of this guide and all the tap-changers referred to shall be presumed to comply with the requirements specified in IEC Publication214. The recommendations of the application guide are not mandatory and only represent advice to the t
12、ap-changer manufacturer and purchaser. The responsibility for the correct application of the fully assembled tap-changer in connection with the transformer is with the manufacturer of the transformer. 2 Selection of a tap-changer 2.1 General remarks Since the tap-changer represents only a small part
13、 of the total cost of the equipment in which it is used, it should be freely chosen to suit the equipment. However, account should be taken of the available standard types of tap-changers. 2.2 Insulation level The following values occurring on all tapping positions of the transformer should be check
14、ed against the tap-changer manufacturers declared values in accordance with Sub-clause8.6.4 of IECPublication214: 1) Normal power-frequency operating voltages appearing on the tap-changer in service. 2) Power-frequency voltages appearing on the tap-changer during tests on the transformer. 3) Impulse
15、 voltages appearing on the tap-changer during tests on the transformer or in service. NOTEWith some winding arrangements, the voltages appearing on the transformer can be abnormally high, e.g.: neutral point tappings in auto-transformers, line-end tappings, and booster transformer arrangements. Thes
16、e voltages can be affected considerably by the choice of linear, coarse/fine or reversing tapping arrangements. Methods of catering for voltage variation which involve variations in the magnetic flux in the transformer core can also affect the voltages appearing on various parts of the tap-changer (
17、seeIECPublication76, Power Transformers). 2.3 Current The tap-changer should satisfy the following conditions: 2.3.1 Rated through-current The rated through-current of the tap-changer as defined in Sub-clause4.17 of IEC Publication214 should be not less than that resulting from the highest value of
18、tapping current of the tapped winding of the transformer(in accordance with Sub-clause4.2 of IEC Publication76-1, Part1:General). 2.3.2 Overload current When tap-changers are fitted on transformers which are subjected to overload conditions in accordance with IEC Publication354, Loading Guide for Oi
19、l-immersed Transformers, they should generally be restricted to the occasional overload conditions stated in Sub-clause4.2 of IEC Publication76-1, unless specifically ordered for other overload conditions by the transformer manufacturer. The above requirements are met: a) If the maximum rated throug
20、h-current of the tap-changer is at least1.2times the highest tapping current of the transformer, or b) if the tap-changer manufacturer is able to demonstrate that the temperature-rise limits given in Sub-clause8.1 of Publication214 are not exceeded when the contacts carry1.2times the maximum rated t
21、hrough-current. (The values of current to apply for the other tests of Clause8 of Publication214 remain based on the value of the maximum rated through-current.) The number of tap-changes for each occasional overload period should be limited to the number of operations corresponding to one-half of o
22、ne complete operating cycle and the peak temperature rise of the transition resistors should not exceed360 C for air-environment tap-changers or300 C for oil-environment tap-changers. Where tap-changers are subject to overload conditions not in accordance with the limitations stated in IEC Publicati
23、on76-1 with regard to the loading guide for oil-immersed transformers, the tap-changer manufacturer should be consulted and given the current magnitude and duration so that the correct tap-changer can be recommended for the duty required.BS5611:1978 2 BSI 12-1999 2.3.3 Short-circuit current The shor
24、t-circuit current of the tap-changer as given in Sub-clause8.3 of IEC Publication214 should be not less than that resulting from the overcurrent of the associated transformer as given in Sub-clause 1.2 of IEC Publication76-5, Part5:Ability to Withstand Short Circuit. NOTEParticular care should be ta
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS56111978APPLICATIONGUIDEFORONLOADTAPCHANGERS 负载 接头 切换 开关 应用 指南 PDF

链接地址:http://www.mydoc123.com/p-545256.html