BS 5241-1-1994 Rigid polyurethane (PUR) and polyisocyanurate (PIR) foam when dispensed or sprayed on a construction site - Specification for sprayed foam thermal insulation applied.pdf
《BS 5241-1-1994 Rigid polyurethane (PUR) and polyisocyanurate (PIR) foam when dispensed or sprayed on a construction site - Specification for sprayed foam thermal insulation applied.pdf》由会员分享,可在线阅读,更多相关《BS 5241-1-1994 Rigid polyurethane (PUR) and polyisocyanurate (PIR) foam when dispensed or sprayed on a construction site - Specification for sprayed foam thermal insulation applied.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 5241-1: 1994 Rigid polyurethane (PUR) and polyisocyanurate (PIR) foam when dispensed or sprayed on a construction site Part 1: Specification for sprayed foam thermal insulation applied externallyBS5241-1:1994 This British Standard, having been prepared under the directionof the P
2、lastics and Rubber Standards Policy Committee, was published underthe authority of the Standards Board and comes intoeffect on 15 March1994 BSI 07-1999 First published June 1989 Second edition March 1994 The following BSI references relate to the work on this standard: Committee reference PRM/72 Dra
3、ft for comment 92/46319 DC ISBN 0 580 22807 X Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Plastics and Rubber Standards Policy Committee (PRM/-) to Technical Committee PRM/72, upon which the following bodies were represented: Associa
4、tion of Building Component Manufacturers Brick Development Association British Board of Agrement British Plastics Federation British Rigid Urethane Foam Manufacturers Association Calcium Silicate Brick Association Limited Cavity Foam Bureau Department of the Environment (Building Research Establishm
5、ent) Department of the Environment (Construction Directorate) Engineering Equipment and Materials Users Association European Phenolic Foam Association Flat Roofing Contractors Advisory Board Ministry of Defence National Federation of Roofing Contractors National House-building Council Polyethylene F
6、oam Insulation Association Royal Institute of British Architects The following bodies were also represented in the drafting of the standard, through subcommittees and panels: British Ceramic Research Ltd. British Urethane Foam Contractors Association (BUFCA) Department of the Environment RAPRA Techn
7、ology Ltd. Amendments issued since publication Amd. No. Date CommentsBS5241-1:1994 BSI 07-1999 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 References 1 3 Designation 1 4 Composition 1 5 Test specimens and sampling 1 6 Physical properties 2 7 Marking 2 Annex A (i
8、nformative) Notes for designers 3 Annex B (normative) Method for determination of apparent water absorption 3 Annex C (informative) Burning properties of rigid polyurethane and polyisocyanurate foam and recommendations regarding their use 4 Table 1 Designation codes for thermal conductivity 1 Table
9、2 Physical properties 2 List of references Inside back coverBS5241-1:1994 ii BSI 07-1999 Foreword This Part of BS5241 has been prepared under the direction of the Plastics and Rubber Standards Policy Committee. It is revision of BS5241-1:1989 which is withdrawn. The1989revision of BS5241:1975 result
10、ed in the separation of the standard into two Parts to reflect trends in current technology. In BS5241-1:1989 the specific requirements of sprayed PUR and PIR foams applied externally were detailed, whereas Part2covered the requirements for applications where the foam is dispensed. Also in BS5241-1:
11、1989 the advice to users was updated, a water absorption method added and the physical property requirements amended to take account of the revised test methods described in the latest revision of BS4370. This edition introduces technical changes but it does not reflect a full review or revision of
12、the standard. A requirement has been included for the thermal conductivity of the foam to be designated by the manufacturer. It is envisaged that this standard will be replaced by a European Standard in due course and that the European Standard will be adopted in the BSEN series. Attention is drawn
13、to BS7021, a code of practice for the thermal insulation of roofs externally by means of sprayed polyurethane (PUR) or polyisocyanurate (PIR) foam, which is published simultaneously. WARNING. Adequate fire precautions should be taken when repairing any structure containing PUR or PIR foams. Do not u
14、se welding or flame cutting equipment. The attention of contractors and purchasers is drawn to the fact that this specification covers the foam only. In almost all cases, sprayed foam requires some surface treatment or covering in order to conform to the surface spread of flame rating appropriate to
15、 the final application (seeAnnex C and BS7021), to provide protection from ultraviolet light and to confer weatherproofing. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance
16、with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1 to 6, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had a
17、mendments incorporated. This will be indicated in the amendment table on the inside front cover.BS5241-1:1994 BSI 07-1999 1 1 Scope This Part of BS5241 specifies the physical property and compositional requirements for externally sprayed polyurethane (PUR) and polyisocyanurate (PIR) foams used for t
18、he thermal insulation of external surfaces, e.g.roofs and storage tanks. 2 References 2.1 Normative references This Part of BS5241 incorporates, by reference, provisions from specific editions of other publications. These normative references are cited at the appropriate points in the text and the p
19、ublications are listed on the inside back cover. Subsequent amendments to, or revisions of, any of these publications apply to this Part of BS5241 only when incorporated in it by updating or revision. 2.2 Informative references This Part of BS5241 refers to other publications that provide informatio
20、n or guidance. Editions of these publications current at the time of issue of this standard are listed on the inside back cover, but reference should be made to the latest editions. 3 Designation For the purposes of this British Standard, the materials are divided into four types, as follows: Types1
21、and2differ principally from types3and4in their burning characteristics. Types2and4are specified where greater robustness is required e.g.in the insulation of roofs externally, where the slope of the roof is less than45 (see3.2 of BS7021:1989). The designation shall consist of a three component code
22、comprising the following items, in the order presented: a) the number and date of this British Standard i.e.BS5241-1:1994; b) a number indicating the foam type; c) a double digit number to indicate the thermal conductivity selected in accordance withTable 1. An example of the designation required fo
23、r a type4foam with a thermal conductivity of0.02W/(mK) is as follows: BS 5241-1:1994/4/20. Table 1 Designation codes for thermal conductivity 4 Composition The material shall be of rigid polyurethane (PUR) or polyisocyanurate (PIR) foam. A material indicated by (PUR) shall be substantially composed
24、of urethane linkages and one indicated by (PIR) shall be substantially composed of isocyanurate linkages. NOTENo requirement for odour is included as its assessment is largely subjective. However, it is recommended that the material should be free from objectionable odour. 5 Test specimens and sampl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS524111994RIGIDPOLYURETHANEPURANDPOLYISOCYANURATEPIRFOAMWHENDISPENSEDORSPRAYEDONACONSTRUCTIONSITESPECIFICATIONFORSPRAYEDFOAMTHERMALINSULATIONAPPLIEDPDF

链接地址:http://www.mydoc123.com/p-544969.html