BS 4819-2-1989 Resistance welding water-cooled transformers of the press-package and portable types - Specification for portable transformers《压装和便携式电阻焊水冷变压器 第2部分 便携式变压器规范》.pdf
《BS 4819-2-1989 Resistance welding water-cooled transformers of the press-package and portable types - Specification for portable transformers《压装和便携式电阻焊水冷变压器 第2部分 便携式变压器规范》.pdf》由会员分享,可在线阅读,更多相关《BS 4819-2-1989 Resistance welding water-cooled transformers of the press-package and portable types - Specification for portable transformers《压装和便携式电阻焊水冷变压器 第2部分 便携式变压器规范》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 4819-2: 1989 Resistance welding water-cooled transformers of the press-package and portable types Part 2: Specification for portable transformers UDC 621.314.21:621.791.763BS4819-2:1989 This British Standard, having been prepared under the directionof the Welding Standards Policy
2、 Committee, waspublished under the authorityof the Board ofBSIandcomes into effect on 29September1989 BSI 11-1999 First published as BS4819July1972 First revision as BS4819-2 The following BSI references relate to the work on this standard: Committee reference WEE/26 Draft for comment 88/70774 DC IS
3、BN 0 580 17521 9 Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Welding Standards Policy Committee (WEE/-) to Technical Committee WEE/26, upon which the following bodies were represented: Association of Supervisory and Executive Enginee
4、rs British Non-ferrous Metals Federation British Steel Industry British Telecommunications plc Copper Development Association Electricity Supply Industry in England and Wales Health and Safety Executive Society of British Aerospace Companies Limited Society of Motor Manufacturers and Traders Limited
5、 Welding Institute Welding Manufacturers Association (BEAMA Ltd.) Coopted members Amendments issued since publication Amd. No. Date of issue CommentsBS4819-2:1989 BSI 11-1999 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 Definitions 1 3 Service conditions 1 3.1 Ge
6、neral 1 3.2 Altitude 1 3.3 Temperature of the cooling media 1 4 Design and construction 1 4.1 General 1 4.2 Rating 1 4.3 Primary circuit 2 4.4 Secondary circuit 2 4.5 Electromechanical stress 2 4.6 High voltage 2 4.7 Insulation resistance 2 4.8 Protection against ingress of dust and liquids 2 5 Test
7、s 2 5.1 Type tests 2 5.2 Routine tests 3 6 Testing 3 6.1 Temperature rise at thermal rating 3 6.2 Short circuit secondary current using standard load 3 6.3 Electromechanical stress 3 6.4 No-load primary current 3 6.5 Open circuit secondary voltage 3 6.6 Water pressure 4 6.7 Water flow 4 6.8 High vol
8、tage 4 6.9 Insulation resistance 4 6.10 Protection against dust and ingress of liquids 4 7 Measurement of temperature 5 7.1 Temperature test conditions 5 7.2 Winding temperature at end of test 5 8 Safety 6 9 Nameplate 6 Appendix A Relationship between transformer operating dutycycleandinputkVA on an
9、y specified tapping 7 Appendix B Calculation of permissible duty cycle from the thermal rating 8 Figure 1 Secondary standard resistance load for portable weldingtransformer 4 Figure 2 Transformer operating duty cycle and input kVA 7 Table 1 Limits of temperature rise 2 Table 2 Maximum values for no-
10、load power (S o ) and no-load current (I 10 ) 5 Publications referred to Inside back coverBS4819-2:1989 ii BSI 11-1999 Foreword This revision of BS4819 has been prepared under the direction of the Welding Standards Policy Committee. It forms one of a series of standards dealing with resistance weldi
11、ng equipment. It supersedes BS4819:1972, which is withdrawn. In this edition BS4819 has been divided into two Parts dealing with press package transformers and with portable transformers respectively. This was done so that subsequent revisions could be made to one part without affecting the other, p
12、articularly in view of the international input into the requirements on press package transformers. This Part has been prepared to meet the needs of manufacturers and users for standardizing the dimensional requirements and method of rating transformers for portable spot welding guns. A British Stan
13、dard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover,
14、 an inside front cover, pages i and ii, pages1 to 8, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS4819-2:1989 BSI 11-1999 1 1 Scope This P
15、art of BS4819 specifies the requirements, methods of test, service conditions and rating of single-phase, mains frequency resistance welding water-cooled transformers of the portable type having a primary voltage of660V or less. NOTEThe titles of the publications referred to in this standard are lis
16、ted on the inside back cover. 2 Definitions For the purposes of this British Standard the following definitions apply. For other relevant terms the definitions in BS499-1 apply. 2.1 duty cycle the time that the load is applied, expressed as a percentage of the integrating period NOTE 1The terms “dut
17、y factor” and “duty cycle” are synonymous. NOTE 2In this standard the word “load” should be considered in a restricted manner. It refers to a constant electrical load without periods of pre-heat, post-heat and slope-control. 2.2 integrating period the sum of one load period and one no-load period 2.
18、3 thermal rating the maximum electrical input, in kVA, at a duty cycle of50% with a1min integrating period, without exceeding the specified temperature NOTEFor the thermal rating at other duty cycles, seeAppendix A. 2.4 portable transformer a transportable water-cooled transformer consisting of a pr
19、imary and secondary winding, electrically isolated from each other, used to supply welding current to, but remote from, a portable spot welding gun or guns 2.5 rated secondary current the current, calculated by dividing the thermal rating by the maximum open circuit secondary voltage, obtainable by
20、series connection of the secondary windings 2.6 rated primary current the current calculated by dividing the thermal rating by the rated primary voltage 2.7 rated primary voltage the voltage applied directly to the transformer primary winding NOTEThis voltage is not necessarily the same as the suppl
21、y voltage. 3 Service conditions 3.1 General This British Standard is applicable when transformers are used under the conditions given in3.2 and3.3. 3.2 Altitude The height above sea level at which the transformer is intended to work in ordinary service shall not exceed1000m. 3.3 Temperature of the c
22、ooling media The temperature of the cooling water flowing shall be less than30 C at the inlet and the ambient air temperature shall be less than40 C. 4 Design and construction 4.1 General The transformer shall be of the double wound type, the primary winding being electrically isolated from the seco
23、ndary winding by means of reinforced insulation in accordance with BS2754. Live parts shall be so insulated or supported that they do not come into electrical contact with one another or with any earthing conductor or metal parts exposed to personal contact. Live parts shall be so enclosed that no p
24、erson can inadvertently come into contact with any live part that can normally attain a potential in excess of55V above earth potential. Covers for the guarding of live parts shall be effectively secured in position in such a way that their removal requires the use of a tool. All exposed conductive
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS481921989RESISTANCEWELDINGWATERCOOLEDTRANSFORMERSOFTHEPRESSPACKAGEANDPORTABLETYPESSPECIFICATIONFORPORTABLETRANSFORMERS

链接地址:http://www.mydoc123.com/p-544686.html