BS 3531-14 2-1990 Implants for osteosynthesis - Intramedullary nailing systems - Specification for medullary pins (Rush type) and introducer extractors《骨接合术用外科植入物 第14部分 骨髓腔内钉接物系列 第.pdf
《BS 3531-14 2-1990 Implants for osteosynthesis - Intramedullary nailing systems - Specification for medullary pins (Rush type) and introducer extractors《骨接合术用外科植入物 第14部分 骨髓腔内钉接物系列 第.pdf》由会员分享,可在线阅读,更多相关《BS 3531-14 2-1990 Implants for osteosynthesis - Intramedullary nailing systems - Specification for medullary pins (Rush type) and introducer extractors《骨接合术用外科植入物 第14部分 骨髓腔内钉接物系列 第.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS3531-14.2: 1990 Implants for osteosynthesis Part14: Intramedullary nailing systems Section14.2 Specification for medullary pins (Rush type) and introducer/extractorsBS3531-14.2:1990 This British Standard, having been prepared under the directionof the Health Care Standards Policy
2、Committee, waspublished under the authorityof the Board of BSI andcomes into effect on 31August1990 BSI 10-1999 The following BSI references relate to the work on this standard: Committee reference HCC/22 Draft announced in BSI News October1989 ISBN 0 580 18357 2 Committees responsible for this Brit
3、ish Standard The preparation of this British Standard was entrusted by the Health Care Standards Policy Committee (HCC/-) to Technical Committee HCC/22, upon which the following bodies were represented: British Institute of Surgical Technologists British Investment Casting Trade Association British
4、Medical Association British Orthopaedic Association British Steel Industry British Surgical Trades Association Incorporated Department of Health Institute of Sterile Services Management Medical Sterile Products Association Ministry of Defence National Association of Theatre Nurses Royal College of S
5、urgeons of England Royal Veterinary College Scottish Office Coopted members Amendments issued since publication Amd. No. Date of issue CommentsBS3531-14.2:1990 BSI 10-1999 i Contents Page Committees responsible Inside front cover Foreword ii Section 1. General 1 Scope 1 Section 2. Medullary pins (Ru
6、sh type) 2 Materials 1 3 Method of manufacture 1 4 Finish 1 5 Dimensions and design 1 6 Mechanical properties 2 7 Marking and packaging 2 Section 3. Introducer/extractors for use with medullary pins 8 Materials 3 9 Dimensions 3 Figure 1 Medullary pin 2 Figure 2 Introducer/extractor for use with medu
7、llary pins 3 Table 1 Dimensions and range of sizes of medullary pins 1 Table 2 Minimum tensile strength and minimum elongation of pins made of austenitic stainless steel 2 Table 3 Dimensions of introducer/extractors for use with medullary pins 3 Publications referred to Inside back coverBS3531-14.2:
8、1990 ii BSI 10-1999 Foreword This Section of BS3531 has been prepared under the direction of the Health Care Standards Policy Committee and supersedes BS3531-14:1984, which is withdrawn. Requirements for orthopaedic implants (then termed “surgical implants”) were first published in1962 as BS3531. In
9、1968 a part revision of BS3531:1962 was issued as BS3531-1, which dealt with surgical implants made of all materials. In1980 the first four Parts of a multi-part version of BS3531 were published. A further19 Parts of BS3531 were subsequently published, Part14:1984 giving requirements for Rush type m
10、edullary pins and introducer/extractors. In view of the increase in the number of Parts, and with a view to facilitating the implementation of published or forthcoming international implant standards, the British Standard relating to implants has been restructured. Accordingly, the number BS3531 is
11、reserved for standards for implants for osteosynthesis, BS7251 covers joint prostheses, BS7252 covers metallic materials for surgical implants, BS7253 covers non-metallic materials for surgical implants and BS7254 covers orthopaedic implants i.e.aspects common to both osteosynthesis and joint replac
12、ement. In the restructure, the opportunity has been taken to group together specifications for medullary nailing systems as BS3531-14, which will be published in a number of Sections. This Section of BS3531 introduces editorial changes to reflect this restructuring and up-dates cross-references but
13、otherwise makes no changes to the specification for medullary pins and introducer/extractors first published as BS3531-14:1984. It does not reflect a full review or revision of the standard which will be undertaken in due course. The technical requirements of this Section of BS3531 are based extensi
14、vely on those of ISO5837-2:1980 “Implants for surgery Intramedullary nailing systems Part2: Medullary pins” prepared by Technical Committee150, Implants for surgery, of the International Organization for Standardization (ISO) but with the following additional requirements: a) a maximum value for the
15、 width of the crook end; b) mechanical properties for the pins; c) materials of construction in accordance with BS7252; d) marking and packaging in accordance with BS7254-1; e) restrictions on shape of point; f) dimensions for relevant introducer/extractors. Once implantation has been completed, an
16、implant should never be reused after removal. It is strongly recommended that the products specified in this Section of BS3531 should be manufactured according to the recommendations given in the “Guide to Good Manufacturing Practice for Orthopaedic Implants”. 1) Product certification. Users of this
17、 British Standard are advised to consider the desirability of third party certification of product conformity with this British Standard based on testing and continued surveillance, which may be coupled with assessment of a suppliers quality systems against the appropriate Part of BS5750. Enquiries
18、as to the availability of third party certification schemes will be forwarded by BSI to the Association of Certification Bodies. If a third party certification scheme does not already exist, users should consider approaching an appropriate body from the list of Association members. 1) Compiled by th
19、e Department of Health and Social Security; published and available from Her Majestys Stationary Office ISBN0 11 320846 4.BS3531-14.2:1990 BSI 10-1999 iii A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their c
20、orrect application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi toiv, pages1 to4, an inside back cover and a back cover. This standard has been updated (see copyrig
21、ht date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.iv blankBS3531-14.2:1990 BSI 10-1999 1 Section 1. General 1 Scope This Section of BS3531 specifies the main dimensions of, and requirements for, semi-rigid medullary pins of the
22、 type generally referred to as “Rush pins” for use in orthopaedic surgery, and for introducer/extractors for use with such medullary pins. Other types of medullary pin, e.g.flexible or Enders pins, are excluded. NOTEThe titles of the publications referred to in this standard are listed on the inside
23、 back cover. Section 2. Medullary pins (Rush type) 2 Materials Medullary pins shall be made of wrought austenitic stainless steel complying with BS7252-1 or BS7252-9, or of cold-worked wrought cobalt-chromium-tungsten-nickel alloy complying with BS7252-5 or of wrought titanium alloy complying with B
24、S7252-3. NOTEIt is frequently a contractual requirement for the supplier of the pins to produce evidence that the pins have been manufactured from material complying with the requirements of clause2. 3 Method of manufacture The pins shall be manufactured by a cold-drawing or cold-working process. We
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS35311421990IMPLANTSFOROSTEOSYNTHESISINTRAMEDULLARYNAILINGSYSTEMSSPECIFICATIONFORMEDULLARYPINSRUSHTYPEANDINTRODUCEREXTRACTORS

链接地址:http://www.mydoc123.com/p-543746.html