BS 1251-2015 Open-fireplace components《明壁炉部件》.pdf
《BS 1251-2015 Open-fireplace components《明壁炉部件》.pdf》由会员分享,可在线阅读,更多相关《BS 1251-2015 Open-fireplace components《明壁炉部件》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS 1251:2015Open-fireplace componentsPublishing and copyright informationThe BSI copyright notice displayed in this document indicates when the documentwas last issued. The British Standards Institution 2015Published by BSI Standards Limited 2015ISBN 978 0 580 57839 7ICS 97.
2、100.30The following BSI references relate to the work on this document:Committee reference RHE/28Draft for comment 13/30157623 DCPublication historyFirst published November 1945Second edition October 1959Third edition November 1970Fourth edition October 1987Fifth (present) edition March 2015Amendmen
3、ts issued since publicationDate Text affectedBS 1251:2015 BRITISH STANDARDContentsForeword ii1 Scope 12 Normative references 13 Firebacks 14 Prefabricated fireplace surrounds and hearths 45 Throat forming lintels 126 Marking 14AnnexesAnnex A (normative) Heat resistance test 15Bibliography 16List of
4、figuresFigure1Typical assembly of open-fireplace components 2Figure 2 Firebacks 3Figure 3 Depth of recess and thickness of surround (Recessed surround viewedfrom back face) 5Figure 4 Frame fixing 6Figure 5 Throat hood/Otty hood 6Figure 6 Cut stone fire surround 8Figure 7 Heat plate 9Figure8Typical f
5、ixing brackets for cut stone surrounds 11Figure9Typical fixing locations for cut stone surrounds 11Figure 10 Precast concrete throat-forming lintel 13List of tablesTable 1 Fireback dimensions 4Table 2 Dimensions of fireplace openings 4Summary of pagesThis document comprises a front cover, an inside
6、front cover, pages i to ii,pages 1 to 16, an inside back cover and a back cover.BRITISH STANDARD BS 1251:2015 The British Standards Institution 2015 iForewordPublishing informationThis British Standard is published by BSI Standards Limited, under licence fromThe British Standards Institution, and ca
7、me into effect on 31 March 2015. It wasprepared by Technical Committee RHE/28, Domestic solid mineral fuelappliances. A list of organizations represented on this committee can beobtained on request to its secretary.SupersessionThis British Standard supersedes BS 1251:1987, which is withdrawn.Informa
8、tion about this documentThe principal changes introduced by this revision are as follows. Mention of different materials currently used in the construction offireplaces and their suitability. The minimum projection of the hearth of inset open fires has beendecreased in accordance with the Building R
9、egulations 1, 2 and 3. Requirements are specified for mechanical fixings for cut stone and boxedsection fireplace surrounds to secure them to chimney breasts.Presentational conventionsThe provisions of this standard are presented in roman (i.e. upright) type. Itsrequirements are expressed in sentenc
10、es in which the principal auxiliary verb is“shall”.Commentary, explanation and general informative material is presented insmaller italic type, and does not constitute a normative element.It should be noted that many desirable properties of open-fireplace componentscannot be specified objectively. H
11、owever, attention is drawn to the notes in thisstandard and to BS 8303, which gives guidelines for their assembly.Contractual and legal considerationsThis publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application.Compliance w
12、ith a British Standard cannot confer immunity from legalobligations.BRITISH STANDARDBS 1251:2015ii The British Standards Institution 20151 ScopeThis British Standard specifies requirements for components which, whenassembled in accordance with BS 8303, form the setting for inset open fires ofnominal
13、 sizes 400 mm and 450 mm (see Figure 1).Clause 3 specifies requirements for firebacks for inset open fires without boilersor underfloor air supply used with solid fuel.Clause 4 specifies requirements for prefabricated fireplace surrounds and hearthsand excludes constructional hearths at floor level
14、(see Figure 1).Clause 5 specifies requirements for precast, reinforced concrete throat-forminglintels, excluding those designed to form part of a complete appliance.NOTE 1 Lintels conforming to this British Standard are suitable for use asload-bearing supports for brickwork.NOTE 2 Requirements for f
15、ireguards are specified in BS 8423.2 Normative referencesThe following documents, in whole or in part, are normatively referenced in thisdocument and are indispensable for its application. For dated references, onlythe edition cited applies. For undated references, the latest edition of thereference
16、d document (including any amendments) applies.BS 4550-3, Methods of testing cement Part 3: Physical testsBS 4550-6, Methods of testing cement Part 6: Standard sand for mortar cubesBS 8303, Installation of domestic heating and cooking appliances burning solidmineral fuelsBS EN 197-1, Cement Part 1: C
17、omposition, specifications and conformity criteriafor common cementsBS EN 12390-3, Testing hardened concrete Part 3: Compressive strength of testspecimensBS EN 12620, Aggregates for concreteBS EN 14647, Calcium alumina cement Composition, specifications andconformity3 Firebacks3.1 DesignFirebacks sh
18、all be designed for installation in two, four or five pieces, as shownin Figure 2a).NOTE Two-piece firebacks may be manufactured in two separate sections, or in onesection with suitable horizontal scribing to enable the pieces to be readily separatedbefore installation.3.2 DimensionsThe dimensions o
19、f firebacks, when assembled without jointing, shall be as givenin Figure 2b) and Table 1.NOTE 1 Internal and vertical external angles may be sharp or rounded to a radiusnot exceeding 10 mm. External edges at the rear may be rounded to reduce the riskof damage to the edges.BRITISH STANDARD BS 1251:20
20、15 The British Standards Institution 2015 1Dimensions A and B shall be measured at the point where straight lines alongthe wings intersect straight lines along the front and back of the firebacks. Theminimum thickness of the firebacks at any point shall be 40 mm.NOTE 2 It is desirable for firebacks
21、to be made with a shallow groove in the frontface not less than 20 mm from the inner edge, to permit the insertion ofnon-combustible rope to ensure that the fireback forms an adequate seal to theback of the fireplace surround.Figure 1 Typical assembly of open-fireplace componentsKey1 Corrugated card
22、board 7 Insulating backfill2 Fireback 8 Mantel shelf3 Insulating backfill 9 Fireplace surround lintel4 Flaunching in heat-refractory mortar 10 Fireplace surround5 Factory-made gather 11 Fireplace surround jamb6 Flue linerNOTE Insulating backfill should be either:a) 1 part ordinary Portland cement to
23、 20 parts suitable lightweight expanded clay aggregate, minimally wetted;orb) 1 part ordinary Portland cement to 6 parts Vermiculite; orc) 1 part ordinary Portland cement to 10 parts Perlite.BRITISH STANDARDBS 1251:20152 The British Standards Institution 2015Figure 2 FirebacksTwo-piece Four-piece Fi
24、ve-piecea) Types of sectional firebacksb) Fireback dimensions (see Table 1)BRITISH STANDARD BS 1251:2015 The British Standards Institution 2015 3Table 1 Fireback dimensionsNominalsize of fireDimensionAA)BA)CA)DEF GB)HB)JC)KD)LB)MB)mm mm mm mm mm mm mm mm mm mm mm mm mm0to3 0to3 0to3400 380 250 170 5
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS12512015OPENFIREPLACECOMPONENTS 壁炉 部件 PDF
