BS 1212-2-1990 Float operated valves - Specification for diaphragm type float operated valves (copper alloy body) (excluding floats)《浮子阀 第2部分 隔膜式浮子阀(铜合金阀体)(不含浮子)规范》.pdf
《BS 1212-2-1990 Float operated valves - Specification for diaphragm type float operated valves (copper alloy body) (excluding floats)《浮子阀 第2部分 隔膜式浮子阀(铜合金阀体)(不含浮子)规范》.pdf》由会员分享,可在线阅读,更多相关《BS 1212-2-1990 Float operated valves - Specification for diaphragm type float operated valves (copper alloy body) (excluding floats)《浮子阀 第2部分 隔膜式浮子阀(铜合金阀体)(不含浮子)规范》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 1212-2: 1990 Float operated valves Part 2: Specification for diaphragm type floatoperated valves (copper alloy body) (excluding floats) UDC 621.646.618:621.646.38BS1212-2:1990 This British Standard, having been prepared under the directionof the Building ServicesStandards Committ
2、ee, was published under the authorityof the Board of BSI andcomes into effect on 29 June 1990 BSI 01-2000 First published September 1970 First revision June 1990 The following BSI references relate to the work on this standard: Committee reference SEB/2 Draft for comment 83/11865 DC ISBN 0 580 15846
3、 2 Committees responsible for this BritishStandard The preparation of this British Standard was entrusted by the Building Services Standards Committee (SEB/-) to Technical Committee SEB/2 upon which the following bodies were represented: Association of Manufacturers of Domestic Electrical Appliances
4、 Association of Manufacturers of Domestic Unvented Supply Systems Equipment (MODUSSE) Association of Water Officers Ltd. British Bath Manufacturers Association British Gas Corporation British Non-ferrous Metals Federation British Plastics Federation British Valve Manufacturers Association Ltd. Build
5、ers Merchants Federation Consumer Standards Advisory Committee of BSI Copper Tube Fittings Manufacturers Association Council of British Ceramic Sanitaryware Manufacturers Department of the Environment (Building Research Establishment) Department of the Environment (Property Services Agency) Departme
6、nt of the Environment (Water Directorate) Department of Trade and Industry (National Weights and Measures Laboratory) Institute of Clerks of Works of Great Britain Inc. Institute of Plumbing Institution of Gas Engineers Institution of Public Health Engineers Institution of Water Engineers and Scient
7、ists Metal Sink Manufacturers Association National Association of Plumbing, Heating and Mechanical Services Contractors National Brassfoundry Association Royal Institute of British Architects Society of British Gas Industries South London Consortium Water Authorities Association Water Companies Asso
8、ciation Amendments issued since publication Amd. No. Date of issue CommentsBS1212-2:1990 BSI 01-2000 i Contents Page Committees responsible Inside front cover Foreword iii Section 1. General 1 Scope 1 2 Definition 1 3 Designation for ordering 1 4 Marking 1 Section 2. Materials 5 Quality and finish 2
9、 6 Plastics 2 7 Castings 2 8 Hot stampings 2 9 Mouldings 2 10 Machining 2 Section 3. Design, construction and dimensions 11 General 4 12 Screw threads 4 13 Inlet connection 4 14 Backnuts 4 15 Bodies 4 16 Body coupling nuts 4 17 Backplate nuts 4 18 Backplates 5 19 Backplate plungers 5 20 Seats 5 21 D
10、iaphragms 5 22 Levers 5 23 Float adjusters and thumb screws 5 24 Split cotter pins 5 25 Discharge arrangement 5 Section 4. Performance 26 Hydraulic pressure and shut-off 6 27 Backnut distortion 6 28 Backflow prevention 6 29 Flow 6 30 Hydraulic pressure on discharge arrangement 6 Appendix A Method of
11、 test for shut-off when assembled with appropriate float 17 Appendix B Method of test for distortion of size “ plastics backnuts 17 Appendix C Method of test for backflow prevention 17 Appendix D Method of test for flow 18 Appendix E Method of test for effect of hydraulic pressure on discharge arran
12、gement 18 Figure 1 Section of typical size diaphragm type float operated valve 6 Figure 2 Inlet shanks 8 Figure 3 Inlet elbows 9 Figure 4 Backnuts 10BS1212-2:1990 ii BSI 01-2000 Page Figure 5 Body 11 Figure 6 Body coupling nuts 12 Figure 7 Backplate nuts 12 Figure 8 Backplate 13 Figure 9 Backplate p
13、lunger 13 Figure 10 Seats and joint ring for seats 14 Figure 11 Diaphragm 15 Figure 12 Lever 16 Figure 13 Float adjuster and thumb screw 16 Figure 14 Typical arrangement of apparatus for backflow prevention test 19 Figure 15 Typical arrangement of apparatus for flow test 19 Table 1 Materials 3 Table
14、 2 Seats 15 Table 3 Seat and float combination 17 Publications referred to Inside back coverBS1212-2:1990 BSI 01-2000 iii Foreword This Part of BS1212 has been prepared under the direction of the Building Services Standards Committee and specifies requirements for diaphragm type float operated valve
15、s (excluding floats). It supersedes BS1212-2:1970, which is withdrawn. The new features in this Part of BS1212 include the following: a) the possible production of certain components from plastics materials; b) a seat numbering system; c) a bottom entry inlet connection and its associated inlet elbo
16、w, with adjustable stay; d) a recognition of the greater lifting effort of plastics floats over copper floats of equivalent size; e) a test for plastics backnut strength, in line with BS1212-3; f) a recognition of current manufacturing practice by deletion of reference to the use of agate tipped sea
17、ts; g) a recognition of methods of attachment of the discharge arrangements currently used in float valves manufactured in accordance with BS1212-3, and a test to verify their effectiveness; h) a modification of the method of dimensioning some components to ensure the lever does not rise above the h
18、orizontal at valve closure; j) the dimensional alignment of the body inlet connection with BS1212-1, which now requires only one seat joint ring for either plastics or metal seats. Float operated valves complying with BS1212-2 and carrying the Kitemark are automatically eligible for listing in the W
19、ater Research Centre Fittings Scheme Directory of Water Fittings. This Part of BS1212 has been revised in metric terms, except for certain thread sizes and pipe thread designations which are retained in imperial sizes to accord with BS2779. A British Standard does not purport to include all the nece
20、ssary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i to iv, pages1
21、to 20, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.iv blankBS1212-2:1990 BSI 01-2000 1 Section 1. General 1 Scope This Part of BS1212 speci
22、fies materials, dimensions, tolerances and performance requirements for diaphragm type float operated valves (copper alloy body) of nominal sizes ) and “ with seat numbers 3, 5, 6 and 9 intended for use with floats complying with BS1968 and BS2456. NOTE 1The nominal sizes correspond with the pipe si
23、ze of the thread on the inlet shank as specified in BS2779. The nominal size ) is formed by making a special inlet on the size “. NOTE 2The titles of the publications referred to in this standard are listed on the inside back cover. 2 Definition For the purposes of this Part of BS 1212 the following
24、 definition applies. diaphragm type float operated valve a float operated valve in which the flow of water is controlled by the flexing of a diaphragm and which incorporates or is fitted with a discharge arrangement to conduct water into the cistern to which the float operated valve is to be fitted
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS121221990FLOATOPERATEDVALVESSPECIFICATIONFORDIAPHRAGMTYPEFLOATOPERATEDVALVESCOPPERALLOYBODYEXCLUDINGFLOATS

链接地址:http://www.mydoc123.com/p-542662.html