ATIS 0600012 01-2013 Electrical Primary Protection Considerations for Broadband xDSL Systems.pdf
《ATIS 0600012 01-2013 Electrical Primary Protection Considerations for Broadband xDSL Systems.pdf》由会员分享,可在线阅读,更多相关《ATIS 0600012 01-2013 Electrical Primary Protection Considerations for Broadband xDSL Systems.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、 ATIS-0600012.01 ATIS Standard on - ELECTRICAL PRIMARY PROTECTION CONSIDERATIONS FOR BROADBAND XDSL SYSTEMS As a leading technology and solutions development organization, ATIS brings together the top global ICT companies to advance the industrys most-pressing business priorities. Through ATIS commi
2、ttees and forums, nearly 200 companies address cloud services, device solutions, emergency services, M2M communications, cyber security, ehealth, network evolution, quality of service, billing support, operations, and more. These priorities follow a fast-track development lifecycle from design and i
3、nnovation through solutions that include standards, specifications, requirements, business use cases, software toolkits, and interoperability testing. ATIS is accredited by the American National Standards Institute (ANSI). ATIS is the North American Organizational Partner for the 3rd Generation Part
4、nership Project (3GPP), a founding Partner of oneM2M, a member and major U.S. contributor to the International Telecommunication Union (ITU) Radio and Telecommunications sectors, and a member of the Inter-American Telecommunication Commission (CITEL). For more information, visit . Notice of Disclaim
5、er Access transmission system on metallic access cables; Symmetrical single pair high bit rate Digital Subscriber Line (SDSL); Part 2: Transceiver requirements.315 ITU-T Recommendation G.991.1, High bit rate Digital Subscriber Line (HDSL.)416 ITU-T Recommendation G.991.2, “Single-pair high-speed dig
6、ital subscriber line (SHDSL) transceivers”.417 ITU-T Recommendation G.992.1, Asymmetric digital subscriber line (ADSL) transceivers.418 ITU-T Recommendation G.992.2, Splitterless asymmetric digital subscriber line (ADSL) transceivers.419 ITU-T Recommendation G.992.3, Asymmetric digital subscriber li
7、ne transceivers 2 (ADSL2).420 ITU-T Recommendation G.992.4, Splitterless asymmetric digital subscriber line transceivers 2 (splitterless ADSL2).41This document is available from the Alliance for Telecommunications Industry Solutions (ATIS), 1200 G Street N.W., Suite 500, Washington, DC 20005. 2This
8、document is available from the Institute of Electrical and Electronics Engineers (IEEE). 3This document is available from the European Telecommunications Standards Institute (ETSI). 4This document is available from the International Telecommunications Union. ATIS-0600012.01 3 21 ITU-T Recommendation
9、 G.992.5, Asymmetric Digital Subscriber Line (ADSL) transceivers - Extended bandwidth ADSL2 (ADSL2+).422 ITU-T Recommendation G.993.1, Very high speed digital subscriber line transceivers (VDSL).423 ITU-T Recommendation G.993.2, Very high speed digital subscriber line transceivers 2 (VDSL2).424 NFPA
10、 70-2011, National Electrical Code (NEC).525 Telcordia Technical Reference TR-EOP-000001, Lightning, Radio Frequency, and 60-Hz Disturbances at the Bell Operating Company Network Interface, Issue 2, June, 1987.626 Telcordia, GR-974-CORE Generic Requirements for Telecommunications Line Protector Unit
11、s.627 Telcordia, GR-3154-CORE Generic Requirements for High-Density Feeder Distribution Interconnection and Surge Protection.628 Telcordia, GR-1089-CORE, Electromagnetic Compatibility (EMC) and Electrical Safety-Generic Criteria for Network Telecommunications Equipment.629 UL60950, Safety of Informa
12、tion Technology Equipment.730 ITU-T K.44, Resistibility tests for telecommunication equipment exposed to overvoltages and overcurrents - Basic Recommendation.43 Definitions, Acronyms, it will conduct current once its breakdown voltage has been exceeded (it is a variable resistor model). 3.1.18 Posit
13、ive Temperature Coefficient (PTC) thermistor: A current limiting device, the resistance of which increases as a function of the temperature caused by the heating effect of the current and PTC resistance. 3.1.19 Primary Protector: Used to protect an equipment interface and wiring system located where
14、 it diverts most of the stressful voltages and currents from propagation into the equipment thus protecting inside wiring. It also minimizes voltage gradients within outside plant wiring but does not limit current in outside plant wiring. It is generally accessible, removable, and connected to equip
15、otential bonding. 3.1.20 Quiescent State (Off-State): The surge protector, while not being exposed to external voltages that would cause it to operate, should present low loss at transmission frequencies. 3.1.21 Thyristor: A semi-conductor device that conducts current by switching into a short-circu
16、it once its breakdown voltage has been exceeded. The thyristor is reset back into its high-impedance state once the current falls below its holding current value. 3.1.22 Transverse Voltage (also known as Differential or Metallic Voltage): A voltage between the tip conductors and the ring conductors.
17、 ATIS-0600012.01 5 3.2 Acronyms Access transmission system on metallic access cables; Symmetrical single-pair high bit rate Digital Subscriber Line (SHDSL); Part 2: Transceiver requirements 14. SHDSL is typically used as a transport technology to commercial customer locations due to its high-speed s
18、ymmetric characteristics. SHDSL can be used by applications that require symmetric access. The international standard for SHDSL is ITU-T Recommendation G.991.2, Single-pair high-speed digital subscriber line (SHDSL) transceivers 16. The highest signal frequencies for SHDSL are: 385kb/s 120 kHz; 784
19、kb/s 250 kHz; 1.56 Mb/s 500 kHz. ADSLx can transmit a high speed down-stream data rate up to 27 Mbps to the subscriber, a lower speed up-stream data rate up to 2 Mbps, and can coexist with Plain Old Telephone Service (POTS). When POTS and ADSLx coexist on the same twisted-pair, then a splitter/filte
20、r is required at the Network End (Central Office, Remote Terminal, etc.) and at the Remote End (Customer Location) to separate the POTS and ADSLx signals. The ADSLx technology is intended for applications such as internet access, multimedia access, and video on demand that can be provided by an asym
21、metric system. The standard for ADSL is ATIS-0600413.2009, Network and Customer Installation Interfaces Asymmetric Digital Subscriber Line (ADSL) Metallic Interface 2. The international standards for ADSL are the ITU-T standards ITU-T Recommendation G.992.1, Asymmetric digital subscriber line (ADSL)
22、 transceivers 17 and ITU-T Recommendation G.992.2, Splitterless asymmetric digital subscriber line (ADSL) transceivers 18. The ADSL2 standards are ITU-T Recommendation G.992.3, Asymmetric digital subscriber line transceivers 2 (ADSL2) 19 and ITU-T Recommendation G.992.4, Splitterless asymmetric digi
23、tal subscriber line transceivers 2 (splitterless ADSL2) 20. The ADSL2plus standard is ATIS-0600417.2007 (R2012), Spectrum Management for Loop Transmissions Systems 3. The international standard is ITU-T Recommendation G.992.5, Asymmetric Digital Subscriber Line (ADSL) transceivers - Extended bandwid
24、th ADSL2 (ADSL2+) 21. The highest signal frequency for ADSL and ADSL2 is 1.1 MHz. VDSLx is similar to ADSLx access but at higher data rates on shorter loop distances than ADSLx and can be symmetric or asymmetric. The VDSL standard is ATIS-0600424.2004 (R2009), Interface between Networks and Customer
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ATIS0600012012013ELECTRICALPRIMARYPROTECTIONCONSIDERATIONSFORBROADBANDXDSLSYSTEMSPDF

链接地址:http://www.mydoc123.com/p-541219.html