1、Designation: F 2208 07Standard Specification forPool Alarms1This standard is issued under the fixed designation F 2208; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates th
2、e year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONAccording to CPSC data it is estimated each year on average, 280 children under five years of agedrown in swimming pools with most deaths occurring in residential setti
3、ngs. Also each year, onaverage, 2200 children under five years of age are treated in hospital emergency rooms for poolsubmersion injuries.1. Scope1.1 This specification covers performance requirements forpool alarms for residential swimming pools and spas.1.2 This specification is intended to descri
4、be devices in-tended to improve personal safety and reduce injuries ordeaths.1.3 This specification covers devices that provide for rapidand automatic detection and alarm in cases of unintentional,unsupervised or accidental entry of a child one year of age orolder into the water of swimming pools or
5、 spas.1.4 This specification is not intended to replace otherstandard safety requirements that should be in place, that is,adult supervision, fences, gates, locks, and so forth.1.5 This specification covers four different types of alarms.1.6 The detection criteria for this standard is for a child on
6、eyear of age and older.1.7 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.8 This standard does not purport to address all of thesafety
7、 concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Definitions of Terms Specific to This Standard:2.1.1 pool a
8、larm, na device designed to provide a rapiddetection and automatic alarm in incidents of accidental,unintentional or unsupervised entry of a child one year of ageor older into the water of a swimming pool or spa.3. Classification3.1 Types:3.1.1 Type A, SurfacePool alarm floating on water sur-face.3.
9、1.2 Type B, SubsurfacePool alarm located below thewater surface.3.1.3 Type C, Pool PerimeterPool alarm located such asto detect movement at the perimeter of or above the watersurface.3.1.4 Type D, Personal Immersion AlarmPool alarm de-vice located on the person(s).4. Performance Requirements4.1 Gene
10、ral:4.1.1 Alarms shall sound both at poolside and inside anyadjacent residence or building of occupancy via a remotereceiver within 20 s or less when tested in accordance withSection 5.4.1.2 The condition of a swimming pool alarm, either on oroff, shall be indicated with an energized lamp or otherdi
11、stinctive indicator, visible from a distance of 10 ft (3.5 m) atangles of 645 perpendicular to the unit, to indicate theoperability of the product.4.1.3 Pool alarms shall have a minimum sound pressurerating of 85 decibels at 10 ft (3.5 m) for 3 min.4.1.4 If the device is battery operated, there must
12、 be a lowbattery indicator. A low battery condition is defined as aninability to meet the requirements of 4.1.3.4.1.5 Pool alarms shall automatically reset.4.2 Type A, Surface Alarm:1This specification is under the jurisdiction of ASTM Committee F15 onConsumer Products and is the direct responsibili
13、ty of Subcommittee F15.49 on PoolSafety Standards.Current edition approved Jan. 1, 2007. Published February 2007. Originallyapproved in 2002. Last previous edition approved in 2002 as F 220802e1.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, Unit
14、ed States.4.2.1 Type A alarms are to provide for automatic sound ofthe alarm when tested in accordance with 5.1. For alarms withvariable sensitivity, the setting shall be set at the least sensitive,according to manufacturers instructions.4.2.2 Type A alarms are not to alarm when tested inaccordance
15、with 5.2. For alarms with variable sensitivity, thesetting shall be set at the most sensitive, according to manu-facturers instructions.4.3 Type B, Subsurface Alarm:4.3.1 Type B alarms are to provide for automatic sound ofthe alarm when tested in accordance with 5.1. For alarms withvariable sensitiv
16、ity, the setting shall be set at the least sensitive,according to manufacturers instructions.4.3.2 Type B alarms are not to alarm when tested inaccordance with 5.2. For alarms with variable sensitivity, thesetting shall be set at the most sensitive, according to manu-facturers instructions.4.4 Type
17、C, Pool Perimeter Alarm:4.4.1 Type C alarms are to provide for automatic sound ofthe alarm when tested in accordance with 5.3, according tomanufacturers instructions.4.4.2 Type C alarms are not to alarm when tested inaccordance with 5.4, according to manufacturers instructions.4.5 Type D, Personal I
18、mmersion Alarm:4.5.1 Type D alarms are to provide for automatic sound ofthe alarm when tested in accordance with 5.5, according tomanufacturers instructions.4.5.2 Type D alarms shall have a key locking device toprevent the removal or disabling of the device.5. Test Procedures5.1 The Child Intrusion
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF22082007STANDARDSPECIFICATIONFORPOOLALARMS 游泳池 报警 器用 标准规范 PDF

链接地址:http://www.mydoc123.com/p-538053.html