ASTM F2138-2009 Standard Specification for Excess Flow Valves for Natural Gas Service《天然气设备用溢流阀标准规范》.pdf
《ASTM F2138-2009 Standard Specification for Excess Flow Valves for Natural Gas Service《天然气设备用溢流阀标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2138-2009 Standard Specification for Excess Flow Valves for Natural Gas Service《天然气设备用溢流阀标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2138 09An American National StandardStandard Specification forExcess Flow Valves for Natural Gas Service1This standard is issued under the fixed designation F 2138; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers requirements and test methodsfor excess flow valves for use in thermoplastic natur
3、al gaspiping systems. However, it is expected that excess flow valvesmanufactured to the requirements of this specification may alsobe used in other natural gas piping systems.1.2 Excess flow valves covered by this specification aredesigned for insertion into components for natural gas systemssuch a
4、s pipe, tubing, or fittings in sizes from 1/2 CTS to 2 IPS.1.3 The tests required by this specification are intended todetermine the performance characteristics of an excess flowvalve installed in a straight piece of pipe. An excess flow valvecould possibly be installed in a straight piece of pipe,
5、in aservice tee outlet, as part of a mechanical coupling, or in otherconfigurations. The performance characteristics of the excessflow valve may be significantly different for each installedconfiguration. Users should conduct their own tests to deter-mine the installed performance characteristics or
6、 contact theEFV manufacturer for test data for the installed configuration.Additional guidance on selection and installation of excessflow valves is included in Appendix X1.1.4 The tests required by this specification are not intendedto be routine quality control tests.1.5 The values stated in inch-
7、pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is the
8、responsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory requirements prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1600 Terminology for Abbreviated Terms Relating toPlasticsF 412 Terminology Relating
9、 to Plastic Piping SystemsF 1802 Test Method for Performance Testing of ExcessFlow Valves3. Terminology3.1 Definitions of Terms:3.1.1 Definitions are in accordance with Terminology F 412,unless otherwise specified. Abbreviations are in accordancewith Terminology D 1600.3.1.2 bypass flow, nan intenti
10、onal rate of passage ofnatural gas through an EFVB after trip, which will allowupstream and downstream pressure to equalize across thedevice to automatically reset to the open position after removalof a fault condition.3.1.3 excess flow valve, EFV, na device installed in anatural gas piping system t
11、o automatically stop or limit thepassage of natural gas when the rate of passage of natural gasthrough the device exceeds a predetermined level.3.1.4 excess flow valve bypass, EFVB, nan EFV designedto limit the flow of gas after trip to a small predetermined leveland to reset automatically after the
12、 pressure is equalized acrossthe valve.3.1.5 excess flow valve non-bypass, EFVNB, nan EFVdesigned to stop the flow of gas after trip and to be resetmanually.3.1.6 leak rate, nthe flow of natural gas through anEFVNB after trip.3.1.7 maximum inlet pressure, nthe maximum pressure,as stated by the EFV m
13、anufacturer, at which an EFV isdesigned to function.3.1.8 minimum inlet pressure, nthe minimum pressure, asstated by the EFV manufacturer, at which an EFV is designedto function.3.1.9 pipe, nrefers to both pipe and tubing.3.1.10 reset, vchanging an EFV from a closed position toan open position.3.1.1
14、1 temperature rating, nthe temperature range, asstated by the EFV manufacturer, within which an EFV isdesigned to function.3.1.12 trip, nclosure of an EFV.1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17
15、.60 on Gas.Current edition approved March 1, 2009. Published April 2009. Originallyapproved in 2001. Last previous edition approved in 2001 as F2138011.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMSta
16、ndards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.13 trip flow, nthe rate
17、of passage of natural gasthrough an EFV that will cause the EFV to stop or limit thepassage of natural gas.4. Ordering Information4.1 Purchasers should consider specifying the followingcharacteristics when ordering an EFV:4.1.1 EFVB or EFVNB,4.1.2 Trip flow (see 9.1.1),4.1.3 Maximum inlet pressure (
18、see Section 7),4.1.4 Temperature rating range (see Section 8),4.1.5 Minimum inlet pressure, and4.1.6 Special considerations for insertion of EFV.5. Materials and Manufacture5.1 The physical properties of each material used to producean EFV shall be available from the EFV manufacturer uponrequest.NOT
19、E 1Materials in long-term contact with natural gas of line qualityshould be demonstrated to not adversely affect the performance of theEFV.NOTE 2Materials should have a demonstrated resistance to environ-mental stress cracking when exposed, under stress, to chemical com-pounds encountered in natural
20、 gas piping systems. Such compoundsinclude, but are not limited to, antifreeze solutions used to thaw frozenlines. The effects of liquid environments such as antifreeze agents,odorants, and hydrocarbons are known to be deleterious to some plastics,particularly when under service conditions.6. Dimens
21、ions6.1 The EFV shall be of appropriate dimensions for the pipeor fitting in which it is intended to be inserted.7. Maximum Inlet Pressure7.1 EFVs manufactured under this specification shall have amaximum inlet pressure of at least 125 psig.8. Temperature Rating Range8.1 EFVs manufactured under this
22、 specification shall have atemperature rating range of -20 to 140F (-29 to 60C).9. Design Qualification Requirements9.1 Performance Requirements:9.1.1 Trip FlowThe trip flow shall not be less than theminimum trip flow stated by the EFV manufacturer and shallnot exceed 1.5 times the minimum trip flow
23、 stated by the EFVmanufacturer at any given pressure between the minimum andmaximum inlet pressures, when tested in accordance with 12.2.9.1.2 Leak RateThe leak rate of an EFVNB shall notexceed 0.40 standard ft3/h (0.011 m3/h) when operating be-tween the minimum and maximum inlet pressures, when tes
24、tedin accordance with 12.3.9.1.3 Bypass FlowThe bypass flow of an EFVB shall notexceed 20 standard ft3/h (0.566 m3/h) at a 10 psig (0.07 MPa)inlet pressure, when tested in accordance with 12.4.At all otherpressures between the minimum and maximum inlet pressures,the bypass flow of an EFVB shall not
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF21382009STANDARDSPECIFICATIONFOREXCESSFLOWVALVESFORNATURALGASSERVICE 天然气 备用 溢流 标准规范 PDF

链接地址:http://www.mydoc123.com/p-537848.html