ASTM F925-2002(2008) Standard Test Method for Resistance to Chemicals of Resilient Flooring《弹性地板材料耐化学药品的标准试验方法》.pdf
《ASTM F925-2002(2008) Standard Test Method for Resistance to Chemicals of Resilient Flooring《弹性地板材料耐化学药品的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F925-2002(2008) Standard Test Method for Resistance to Chemicals of Resilient Flooring《弹性地板材料耐化学药品的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 925 02 (Reapproved 2008)Standard Test Method forResistance to Chemicals of Resilient Flooring1This standard is issued under the fixed designation F 925; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method provides a procedure f
3、or determiningthe resistance of resilient floor covering to surface deteriorationwhen exposed to various chemical reagents. This test method isnot intended as a staining test nor as a method to judge surfaceand appearance restoration of the sample after exposure to thechemical reagent.1.2 The values
4、 stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-pri
5、ate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardinformation is provided in Section 5 of this test method.2. Referenced Documents2.1 ASTM Standards:2D 2244 Practice for Calculation of Color Tolerances andColor Differences from In
6、strumentally Measured ColorCoordinatesF 142 Test Method for Indentation of Resilient Floor Tiles(McBurney Test)3F 386 Test Method for Thickness of Resilient FlooringMaterials Having Flat SurfacesF 1914 Test Methods for Short-Term Indentation and Re-sidual Indentation of Resilient Floor Covering3. Si
7、gnificance and Use3.1 Resilient flooring products are designed and formulatedto have good resistance to most common chemicals encoun-tered in typical use. High performance wear layers can also beused to enhance cleanability and chemical resistance. Resilientflooring used in residential and commercia
8、l environments maybe subjected to a variety of chemicals through accidentalspillage or as ingredients used for hygienic purposes. Perfor-mance is dependent upon the flooring formulation and that ofthe maintenance products used on the flooring. This testmethod provides a means of estimating the relat
9、ive suscepti-bility of resilient floor covering to change when exposed tochemical reagents.4. Apparatus4.1 Gloves, impervious vinyl or rubber,4.2 Tweezers, or forceps,4.3 Medicine Dropper, 3 in. straight glass with rubber bulbor pipette having a point opening diameter not less than116 in.(1.6 mm) or
10、 greater than564 in. (1.8 mm),4.4 White Facial Tissue.4.5 Watch Glass.4.6 Timer.4.7 Filter Paper.4.8 Small Laboratory Spatula, approximately14 12 in.-wide blade, rounded bottom, not sharpened,4.9 Suitable Spectrophotometer or Colorimeter, with aminimum14 in. (6.35 mm) diameter opening having a coolw
11、hite fluorescent (CWF) or daylight (D-65) light source, orboth, that measures color in CIE L*, a*, b* using CIE 10standard observer and specular included (see Test MethodD 2244).4.10 Indentation Tester, see Test Methods F 142 andF 1914.4.11 Thickness Tester, see Test Method F 386.4.12 Conditioning R
12、oom or Cabinet, equipped with auto-matic temperature and humidity controls that will maintain73.4 6 3.6F (23 6 2C) and 50 6 5 % relative humidity.5. Hazards5.1 A new medicine dropper or pipette should be used foreach test reagent. If the same reagent dispenser apparatus is tobe reused, it shall be t
13、horoughly cleaned in hot soapy water andalcohol, or both, prior to applying each different test reagent.5.2 Check to be sure the colorimeter is properly warmed upand calibrated prior to use.5.3 Be sure specimens are held flat when measuring color.1This test method is under the jurisdiction ofASTM Co
14、mmittee F06 on ResilientFloor Coverings and is the direct responsibility of Subcommittee F06.30 on TestMethods - Performance.Current edition approved Jan. 1, 2008. Published March 2008. Originallyapproved in 1985. Last previous edition approved in 2002 as F 92502.2For referenced ASTM standards, visi
15、t the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken,
16、PA 19428-2959, United States.5.4 Be sure each specimen is marked in the corner on theback for easy identification.5.5 Dispose of chemical test reagents properly. Refer toMaterial Safety Data Sheets (MSDS) or precautions on thelabel for proper disposal. (WarningObserve all necessaryprecautions when h
17、andling test reagents known to be flam-mable or potentially hazardous.)6. Test Specimen6.1 The specimen shall consist of a portion of the test unit atleast 6 by 6 in. (153.4 by 153.4 mm) for each reagent(chemical) to be tested.6.2 Specimens shall be selected with minimal changes insurface texture.6.
18、3 Specimens should be of a color to show potential effectof reagent.7. Procedure7.1 Unless otherwise specified, condition the specimens andthe test reagents (chemicals) for at least 24 h prior to testing.The environment for conditioning and testing is 73.4 6 3.6F(23 6 2C) and 50 6 5 % relative humid
19、ity.7.2 Lay the specimens face up on a firm, flat surface.7.3 Select a test area on the specimen having the flattest areaand color appropriate to show the effect of the reagent anddraw a square approximately 112 by 112 in. (38 by 38 mm)centered on that desired test location.7.4 If using test equipme
20、nt such as an indentation tester,thickness tester or color spectrophotometer to help quantifyspecimen change, take initial readings on the unexposedspecimen and record values as indicated in Fig. 1. All mea-surements should be taken on a relatively flat spot, correspond-ing as closely as possible to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF92520022008STANDARDTESTMETHODFORRESISTANCETOCHEMICALSOFRESILIENTFLOORING 弹性 地板 材料 化学药品 标准 试验 方法

链接地址:http://www.mydoc123.com/p-537570.html