ASTM F1116-2003 Standard Test Method for Determining Dielectric Strength of Dielectric Footwear《测定绝缘鞋靴介电强度的标准试验方法》.pdf
《ASTM F1116-2003 Standard Test Method for Determining Dielectric Strength of Dielectric Footwear《测定绝缘鞋靴介电强度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1116-2003 Standard Test Method for Determining Dielectric Strength of Dielectric Footwear《测定绝缘鞋靴介电强度的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1116 03Standard Test Method forDetermining Dielectric Strength of Dielectric Footwear1This standard is issued under the fixed designation F 1116; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers testing to determine the “Di-electric Strength” of dielectric overfoot and overshoe footwear.Testing is
3、 done over the maximum possible area of thedielectric footwear without permitting flashover between elec-trodes.1.2 The use and maintenance of dielectric footwear isbeyond the scope of this test method.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with i
4、ts use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardstatements appear in 5.2.2. Referenced Documents2.1 ASTM Standards:2D 149 Test Method for Dielect
5、ric Breakdown Voltage andDielectric Strength of Solid Electrical Insulating Materialsat Commercial Power FrequenciesF 1117 Specification for Dielectric Footwear3. Terminology3.1 Descriptions of Terms Specific to This Standard:3.1.1 useras used in 1.3, the entity employing the actualworker utilizing
6、the equipment; if no separate employer, thenthe individual.3.1.2 overfoot footwearfootwear designed to be worndirectly over the feet as the only source of foot covering.3.1.3 overshoe footwearfootwear designed to be wornover existing footwear.4. Significance and Use4.1 Electrical contact injuries to
7、 workers may involve acurrent path through the feet of the worker. The footwearcovered by this specification is dielectrically rated to provideadditional insulation and isolation to the wearer. This testmethod will determine that dielectric footwear has dielectricintegrity at the time of the test.5.
8、 Apparatus5.1 Electrical Test Criteria:5.1.1 Test ProcedureThe footwear shall be immersed inwater or other conducting media to a depth where the flashoverclearance is consistent with the proof test voltage as listed inTable 1. Since the water or other conducting media inside thefootwear forms one te
9、st electrode and the water or the otherconducting media in the container outside the footwear formsthe other electrode, 152 mm or 6 in. of clearance betweenelectrodes consists of 76 mm or 3 in. of clearance from the topof the footwear to the top of the water or other conductingmedia both inside and
10、outside of the footwear. Water isrecommended as the medium for the electrodes to ensurecomplete coverage of the surfaces of the footwear. Water maywick up the inner lining on certain brands of footwear. Toovercome the wicking effect care needs to be taken to keep theinner area above the water dry an
11、d conduct the tests promptlyafter placing the water inside the footwear. The water or otherconducting media inside the footwear forms one test electrodeand shall be connected to one terminal of the voltage source bymeans of a metal chain or sliding rod that dips into theelectode. The water or other
12、conducting media in the containeroutside the footwear forms the other electrode and shall beconnected directly to the other terminal of the voltage source.Due to the weight of water or other types of electrode media,support racks are needed to secure footwear being tested. Themaximum protective area
13、 of the footwear shall be tested. Caremust be taken to thoroughly dry the inside of the footwearfollowing the test and prior to storage. See Fig. 1 and Fig. 2 fortypical test arrangements for dielectric test of rubbers and bootsusing water electrodes.NOTE 1Water used as electrodes should have a mini
14、mum conduc-tance of 0.25 mho.5.2 PrecautionsIt is recommended that the test apparatusbe designed to afford the operator full protection in perfor-mance of his duties. Reliable means of de-energizing andgrounding the high-voltage circuit shall be provided. It isparticularly important to incorporate a
15、 positive means ofgrounding the high-voltage section of the dc test apparatus due1This test method is under the jurisdiction of ASTM Committee F18 onElectrical Protective Equipment for Workers and is the direct responsibility ofSubcommittee F18.15 on Worker Personal Equipment.Current edition approve
16、d Nov. 1, 2003. Published January 2004. Originallyapproved in 1988. Last previous edition approved in 1988 as F 111688.2Annual Book of ASTM Standards, Vol 10.01.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.to the likely presence o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便