1、Designation: E 714 94 (Reapproved 2004)Standard Specification forDisposable Glass Serological Pipets1This standard is issued under the fixed designation E 714; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers disposable glass serologicalpipets, calibrated “to deliver,” used in measuring volumes ofliquids.2. Re
3、ferenced Documents2.1 ASTM Standards:2E 438 Specification for Glasses in Laboratory ApparatusE 542 Practice for Calibration of Laboratory VolumetricApparatusE 920 Specification for Commercially Packaged LaboratoryApparatusE 921 Specification for Export Packaged Laboratory Appa-ratusE 1133 Practice f
4、or Performance Testing of Package Labo-ratory Apparatus for United States Government Procure-ments3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 accuracythe expected distribution of mean volumesaround the stated volume.3.1.2 coeffcient of variationthe expected distribution of
5、individual volumes around the mean volume.3.1.3 disposable pipetsin accordance with this specifica-tion and the expected product performance expressed in thisspecification, those serological pipets which are to be used onetime only. Any institution or individual who reuses a dispos-able pipet must b
6、ear full responsibility for its safety andeffectiveness.4. Materials and Manufacture4.1 The pipets shall be fabricated from borosilicate glass,Type I, Class A or B; or soda-lime glass, Type II, as defined inSpecification E 438.5. Design5.1 ShapePipets shall be straight and of one-piece con-struction
7、. Any cross section of a pipet taken in a planeperpendicular to the longitudinal axis shall be circular.5.2 Delivery TipsDelivery tips shall be made with agradual taper of 10 to 25 mm for capacities up to 2 cm3inclusive, and 15 to 30 mm for the 5-cm3and 10-cm3size(s).The tip end shall be reasonably
8、perpendicular to the longitu-dinal axis of the pipet and shall be firepolished.5.3 Top EndThe 10-cm3and 25-cm3pipet shall have a topend tooled to a diameter of 7 to 9 mm and shall have an overalllength of 15 to 25 mm from the top. The top end shall besuitable for plugging with filtering material. Al
9、l top ends shallbe reasonably perpendicular to the longitudinal axis of thepipet, and shall be firepolished.5.4 Dimensions and Outflow TimesThe limiting dimen-sions and outflow times shall be as shown in Table 1. Outflowtimes shall be determined on unplugged pipets, using distilledwater at 25 6 5C,
10、and by means of a stopwatch.6. Markings6.1 Graduation MarkingsGraduation lines shall be be-tween 0.2 and 0.5 mm in width, and in a plane perpendicular tothe longitudinal axis of the pipet and parallel to each other. Amain graduation line shall extend at least three-fifths of the wayaround the pipet.
11、 The values of all main graduation lines shallbe in Arabic numerals directly above the line referenced.Intermediate graduation lines shall extend at least one-fifth ofthe way around the pipet, and least graduation lines shallextend at least one-seventh of the distance around the pipet.The 0 graduati
12、on line shall be at least 90 mm below the top ofthe pipet on all sizes.6.2 Identification MarkingsEach pipet shall be markedwith the manufacturers or vendors name or trademark, itscapacity, the symbols “TD” (for “to deliver”) and “20C,” andeither a wide band or two narrow bands on the mouthpiece end
13、to signify that the last drop must be blown out to achieve fulldelivery.6.3 CapacityThe pipet capacity, expressed in cubic cen-timetres or millilitres, shall be stated on the package. Theexpected deviation from the stated capacity shall be based on1This specification is under the jurisdiction of AST
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME71419942004STANDARDSPECIFICATIONFORDISPOSABLEGLASSSEROLOGICALPIPETS 一次性 玻璃 血清 吸管 标准规范 PDF

链接地址:http://www.mydoc123.com/p-533377.html