1、Designation: E473 11aE473 14Standard Terminology Relating toThermal Analysis and Rheology1This standard is issued under the fixed designation E473; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number
2、 in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This terminology is a compilation of definitions of terms used in ASTM documents relating to thermal analysis andrheology. This terminology i
3、ncludes only those terms for which ASTM either has standards or is contemplating some action. It isnot intended to be an all-inclusive listing of terms related to thermal analysis and rheology.1.2 This terminology specifically supports the single-word form for terms using thermo as a prefix, such as
4、 thermoanalyticalor thermomagnetometry, while recognizing that for some terms a two-word form can be used, such as thermal analysis. Thisterminology does not support, nor does it recommend, use of the grammatically incorrect, single-word form using thermal as aprefix, such as, thermalanalytical or t
5、hermalmagnetometry.1.3 A definition is a single sentence with additional information included in a Discussion area. It is reviewed every five years.2. Terminologyadiabatic, adjno heat exchange with the surroundings.calorimeter, napparatus for measuring quantities of absorbed or evolved bined, adjthe
6、 application of two or more techniques to different samples at the same time.controlled-rate thermal analysis (CRTA ), na family of techniques that monitors the temperature versus time profile needed tomaintain a chosen, fixed rate of change of a property of a substance.DISCUSSIONCompared to control
7、led-temperature experiments, where the reaction rate tends to increase exponentially and the rate can become limited by heat ormass transfer, CRTA experiments are more likely to involve the chemical reaction as the limiting step. This technique can also improve the resolutionof multiple reactions. F
8、or example, in controlled rate experiments, power to the furnace is controlled to ensure a fixed rate of mass loss (or gain).controlled-temperature program, nthe temperature history experienced by a sample during the course of a thermal analysisexperiment.DISCUSSIONIn contrast to controlled-rate exp
9、eriments, power to the furnace is controlled to ensure a fixed rate of temperature change for controlled-temperatureexperiments. The program may include heating or cooling segments in which the temperature is changed at a fixed rate, isothermal segments in whichtime becomes the explicit independent
10、variable, or any sequence of these individual segments. If the atmosphere (or vacuum) around the sample ischanged by some external action (depending on the independent variable onlytemperature or time) during the course of the experiment, that toobecomes part of the controlled-temperature program.cu
11、rve, thermal, nthe plot of a dependent parameter against an independent parameter such as temperature or time.dielectric analysis (DEA), na technique in which the dielectric constant (permittivity or capacitance) and dielectric loss(conductance) of a substance under oscillating electric field are me
12、asured as a function of temperature or time while thesubstance is subjected to a controlled-temperature program in a specified atmosphere.1 This terminology is under the jurisdiction of ASTM Committee E37 on Thermal Measurements and are the direct responsibility of Subcommittee E37.03 onNomenclature
13、 and Definitions.Current edition approved June 15, 2011Aug. 15, 2014. Published June 2011September 2014. Originally approved in 1973. Last previous edition approved in 2011 asE473 11.E473 11a. DOI: 10.1520/E0473-11A.10.1520/E0473-14.This document is not an ASTM standard and is intended only to provi
14、de the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the s
15、tandard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1derivative, adjpertaining to the first derivative (mathematical) of any curve with respect to temperature or time.d
16、ifferential, adjpertaining to a difference in measured or measurable quantities usually between a substance and some referenceor standard material.differential scanning calorimetry (DSC) , na technique in which the heat flow difference into a substance and a referencematerial is measured as a functi
17、on of temperature while the substance and reference material are subjected to acontrolled-temperature program.DISCUSSIONThe record is the differential scanning calorimetric or DSC curve. Two modes, power compensation differential scanning calorimetry, and heat fluxdifferential scanning calorimetry c
18、an be distinguished, depending on the method of measurement used.DISCUSSIONTwo conventions exist in thermal analysis. In the physicists convention, exothermic behavior increases downward on the thermal curve. In thechemists convention, exothermic behavior increases upward on the thermal curve. Commi
19、ttee E37 takes no position on which convention shall beused. To aid the user, the direction of exothermic (or conversely, endothermic) behavior shall be indicated on each thermal curve.differential thermal analysis (DTA),na technique in which the temperature difference between the substance and a re
20、ferencematerial is measured as a function of temperature, while the substance and reference material are subjected to acontrolled-temperature program.DISCUSSIONThe term quantitative differential thermal analysis covers those uses of DTA where the equipment is designed to produce quantitative results
21、.dilatometry, nsee thermodilatometry.dynamic mechanical analysis (DMA) , na technique in which the storage modulus (elastic response) and loss modulus (viscousresponse) of a substance under oscillatory load is measured as a function of temperature, time, or frequency of oscillation, whilethe substan
22、ce is subjected to a controlled-temperature program in a specified atmosphere.endotherm, nIn thermal analysis, the thermal record of a transition where heat is absorbed by the specimen.evolved gas analysis (EGA),na technique in which the nature or amount, or both, of gas or vapor evolved by a substa
23、nce issubjected to a controlled-temperature program.DISCUSSIONSome specific forms of EGA have become established for investigating different aspects of catalysis, such as reduction, oxidation, or desorption. Inthis context, EGA in a hydrogen atmosphere is known as temperature-programmed reduction (T
24、PR); EGA in an oxygen atmosphere istemperature-programmed oxidation (TPO); and EGA in the absence of decomposition, in an inert atmosphere or vacuum, is temperature-programmeddesorption (TPD). For each technique the method used for gas identification and quantification should always be clearly state
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME4732014RED0444STANDARDTERMINOLOGYRELATINGTOTHERMALANALYSISANDRHEOLOGY 关于 分析 流变学 标准 术语 PDF

链接地址:http://www.mydoc123.com/p-532846.html