ASTM E1701-1995(2018) Standard Classification for Serviceability of an Office Facility for Manageability《办公设施可管理性的标准分类》.pdf
《ASTM E1701-1995(2018) Standard Classification for Serviceability of an Office Facility for Manageability《办公设施可管理性的标准分类》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1701-1995(2018) Standard Classification for Serviceability of an Office Facility for Manageability《办公设施可管理性的标准分类》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1701 95 (Reapproved 2018) An American National StandardStandard Classification forServiceability of an Office Facility for Manageability1,2This standard is issued under the fixed designation E1701; the number immediately following the designation indicates the year oforiginal adoption
2、or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This classification covers pairs of scales (see Figs. 1-8)for classifying an
3、aspect of the serviceability of an officefacility, that is, the capability of an office facility to meetcertain possible requirements for manageability.1.2 Within that aspect of serviceability, each pair of scales(see Figs. 1-8) are for classifying one topic of serviceability.Each paragraph in an Oc
4、cupant Requirement Scale summarizesone level of serviceability on that topic, which occupants mightrequire. The matching entry in the facility rating scale is atranslation of the requirement into a description of certainfeatures of a facility which, taken in combination, indicate thatthe facility is
5、 likely to meet that level of required serviceability.1.3 The entries in the Facility Rating Scale (see Figs. 1-8)are indicative and not comprehensive. They are for quickscanning, to estimate approximately, quickly, andeconomically, how well an office facility is likely to meet theneeds of one or an
6、other type of occupant group, over time. Theentries are not for measuring, knowing, or evaluating how anoffice facility is performing.1.4 This classification can be used to estimate the level ofserviceability of an existing facility. It can also be used toestimate the serviceability of a facility th
7、at has been plannedbut not yet built, such as one for which single-line drawingsand outline specifications have been prepared.1.5 This classification indicates what would cause a facilityto be rated at a certain level of serviceability, but does not statehow to conduct a serviceability rating nor ho
8、w to assign aserviceability score. That information is found in PracticeE1334. The scales in Figs. 1-8 are complimentary to andcompatible with Practice E1334. Each requires the other.1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-i
9、zation established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:3E631 Terminology of Building ConstructionsE1334 Pra
10、ctice for Rating the Serviceability of a Building orBuilding-Related Facility (Withdrawn 2013)4E1679 Practice for Setting the Requirements for the Service-ability of a Building or Building-Related Facility, and forDetermining What Serviceability is Provided or Proposed2.2 ISO Documents:5ISO 6240 Int
11、ernational Standard, Performance Standards inBuildingContents and PresentationISO/DIS 7162 Draft International Standard, PerformanceStandards in BuildingContents and Format of Standardsfor Evaluation of PerformanceISO/DIS 7164 Draft International Standard, PerformanceStandards in BuildingDefinitions
12、 and Means of Expres-sion for the Performance of a Whole Building3. Terminology3.1 Definitions:3.1.1 facility, na physical setting used to serve a specificpurpose.3.1.1.1 DiscussionA facility may be within a building, ora whole building, or a building with its site and surroundingenvironment; or it
13、may be a construction that is not a building.The term encompasses both the physical object and its use.3.1.2 facility serviceabilitythe capability of a facility toperform the function(s) for which it is designed, used, orrequired to be used.3.1.2.1 DiscussionThe scope of this performance is of thefa
14、cility as a system, including its subsystems, components, and1This classification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.25on Whole Buildings and Facilities.Current edition approved March 1, 2018. Published Apri
15、l 2018. Originallyapproved in 1995. Last previous edition approved in 2012 as E1701 95 (2012).DOI: 10.1520/E1701-95R18.2Portions of this document are based on material originally prepared by theInternational Centre for Facilities (ICF) and 1993 by ICF and Minister of PublicWorks and Government Servi
16、ces Canada. Their cooperation in the development ofthis standard is acknowledged.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page
17、 onthe ASTM website.4The last approved version of this historical standard is referenced onwww.astm.org.5Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, Wes
18、t Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Tr
19、ade Organization Technical Barriers to Trade (TBT) Committee.1FIG. 1 Scale B.2.1 for Reliability of External SupplyE1701 95 (2018)2materials and their interactions, such as acoustical,hydrothermal, air purity, and economic; and of the relativeimportance of each performance requirement.3.1.3 offcea p
20、lace, such as a room, suite, or building, inwhich business, clerical, or professional activities are con-ducted.3.1.4 For standard definitions of additional terms applicableto this classification, as well as those in 3.1.1 3.1.3, seeTerminology E631.4. Significance and Use4.1 Each facility rating sc
21、ale in this classification (see Figs.1-8) provides a means to estimate the level of serviceability ofa building or facility for one topic of serviceability, and tocompare that level against the level of any other building orfacility.4.2 This classification can be used for comparing how welldifferent
22、 buildings or facilities meet a particular requirementfor serviceability. It is applicable despite differences suchaslocation, structure, mechanical systems, age, and buildingshape.4.3 This classification can be used to estimate the amount ofvariance of serviceability from target or from requirement
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME170119952018STANDARDCLASSIFICATIONFORSERVICEABILITYOFANOFFICEFACILITYFORMANAGEABILITY 办公 设施 可管理性

链接地址:http://www.mydoc123.com/p-529277.html