1、Designation: E 1701 95 (Reapproved 2005)An American National StandardStandard Classification forServiceability of an Office Facility for Manageability1,2This standard is issued under the fixed designation E 1701; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This classification covers pairs of scales (see Figs. 1-8)for classifying a
3、n aspect of the serviceability of an officefacility, that is, the capability of an office facility to meetcertain possible requirements for manageability.1.2 Within that aspect of serviceability, each pair of scales(see Figs. 1-8) are for classifying one topic of serviceability.Each paragraph in an
4、Occupant Requirement Scale summarizesone level of serviceability on that topic, which occupants mightrequire. The matching entry in the facility rating scale is atranslation of the requirement into a description of certainfeatures of a facility which, taken in combination, indicate thatthe facility
5、is likely to meet that level of required serviceability.1.3 The entries in the Facility Rating Scale (see Figs. 1-8)are indicative and not comprehensive. They are for quickscanning, to estimate approximately, quickly, and economi-cally, how well an office facility is likely to meet the needs ofone o
6、r another type of occupant group, over time. The entriesare not for measuring, knowing, or evaluating how an officefacility is performing.1.4 This classification can be used to estimate the level ofserviceability of an existing facility. It can also be used toestimate the serviceability of a facilit
7、y that has been plannedbut not yet built, such as one for which single-line drawingsand outline specifications have been prepared.1.5 This classification indicates what would cause a facilityto be rated at a certain level of serviceability, but does not statehow to conduct a serviceability rating no
8、r how to assign aserviceability score. That information is found in PracticeE 1334. The scales in Figs. 1-8 are complimentary to andcompatible with Practice E 1334. Each requires the other.2. Referenced Documents2.1 ASTM Standards:E 631 Terminology of Building Constructions3E 1334 Practice for Ratin
9、g the Serviceability of a Buildingor Building-Related Facility3E 1679 Practice for Rating Serviceability of a Building orBuilding-Related Facility32.2 ISO Documents:4ISO 6240 International Standard, Performance Standards inBuildingContents and PresentationISO/DIS 7162 Draft International Standard, P
10、erformanceStandards in BuildingContents and Format of Standardsfor Evaluation of PerformanceISO/DIS 7164 Draft International Standard, PerformanceStandards in BuildingDefinitions and Means of Expres-sion for the Performance of a Whole Building3. Terminology3.1 Definitions:3.1.1 facility, na physical
11、 setting used to serve a specificpurpose.3.1.1.1 DiscussionA facility may be within a building, ora whole building, or a building with its site and surroundingenvironment; or it may be a construction that is not a building.The term encompasses both the physical object and its use.3.1.2 facility serv
12、iceabilitythe capability of a facility toperform the function(s) for which it is designed, used, orrequired to be used.3.1.2.1 DiscussionThe scope of this performance is of thefacility as a system, including its subsystems, components, andmaterials and their interactions, such as acoustical, hydroth
13、er-mal, air purity, and economic; and of the relative importance ofeach performance requirement.1This classification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.25on Whole Buildings and Facilities.Current edition app
14、roved May 1, 2005. Published May 2005. )riginally approvedin 1995. Last previous edition approved in 1999 as E 1701 95 (1999).2Portions of this document are based on material originally prepared by theInternational Centre for Facilities (ICF) and r 1993 by ICF and Minister of PublicWorks and Governm
15、ent Services Canada. Their cooperation in the development ofthis standard is acknowledged.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Sum
16、mary page onthe ASTM website.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.FIG. 1 Scale B.2.1 for Reliability of External Su
17、pplyE 1701 95 (2005)23.1.3 offcea place, such as a room, suite, or building, inwhich business, clerical, or professional activities are con-ducted.3.1.4 For standard definitions of additional terms applicableto this classification, as well as those in 3.1.1-3.1.3, seeTerminology E 631.4. Significanc
18、e and Use4.1 Each facility rating scale in this classification (see Figs.1-8) provides a means to estimate the level of serviceability ofa building or facility for one topic of serviceability, and tocompare that level against the level of any other building orfacility.4.2 This classification can be
19、used for comparing how welldifferent buildings or facilities meet a particular requirementfor serviceability. It is applicable despite differences suchaslocation, structure, mechanical systems, age, and buildingshape.4.3 This classification can be used to estimate the amount ofvariance of serviceabi
20、lity from target or from requirement, fora single office facility, or within a group of office facilities.4.4 This classification can be used to estimate the following:4.4.1 Serviceability of an existing facility for uses otherthan its present use.4.4.2 Serviceability (potential) of a facility that
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME170119952005STANDARDCLASSIFICATIONFORSERVICEABILITYOFANOFFICEFACILITYFORMANAGEABILITY 可管理性 办公设备

链接地址:http://www.mydoc123.com/p-529275.html