ASTM E1684-2010 Standard Specification for Miniature Thermocouple Connectors《小型热电偶连接器标准规范》.pdf
《ASTM E1684-2010 Standard Specification for Miniature Thermocouple Connectors《小型热电偶连接器标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1684-2010 Standard Specification for Miniature Thermocouple Connectors《小型热电偶连接器标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1684 10Standard Specification forMiniature Thermocouple Connectors1This standard is issued under the fixed designation E1684; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in pare
2、ntheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers separable single-circuit minia-ture thermocouple connectors with two flat pins. Connectorscovered by this specification mus
3、t be rated for continuous useto at least 300F (150C), but they may optionally be ratedhigher.1.2 This specification does not cover multiple-circuit con-nectors, multi-pin connectors, standard size connectors, orconnectors intended primarily for panel mounting. High-temperature connectors (for exampl
4、e, those designed for con-tinuous use at temperatures significantly above approximately500F (260C) are not intended to be covered by thisspecification.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.4 The plug and
5、 jack may be ordered separately but manyof the connector characteristics (see Table 1) are qualified as amated pair. The requirements in this standard are applicable forthe connector pair supplied by the same manufacturer.1.5 The following precautionary statement pertains only tothe test methods por
6、tion, Section 9, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-t
7、ions prior to use.2. Referenced Documents2.1 The following documents of the latest issue form a partof this specification to the extent referenced herein. In case ofconflict between this specification and another referenceddocument, this specification shall take precedence.2.2 ASTM Standards:2E230 S
8、pecification and Temperature-Electromotive Force(EMF) Tables for Standardized ThermocouplesE344 Terminology Relating to Thermometry and Hydrom-etry3. Terminology3.1 DefinitionsThe definitions given in TerminologyE344 shall apply.3.2 Definitions of Terms Specific to This Standard:3.2.1 connector pair
9、, nassembly consisting of a plug anda jack, each having both positive and negative inserts, that willconnect two parts of an electrical circuit and provide a meansof physically disconnecting the two parts without the use oftools.3.2.2 contact insert, nmetallic conductor assemblies that,when installe
10、d in connector bodies, provide connections be-tween two parts of an electrical circuit. Plug connectors willcontain projecting prong contacts, while jack connectors willcontain recessed socket or receptacle contacts.3.2.3 service life, ninterval of time that a connectorassembly will be put to use an
11、d retain all physical andthermoelectric properties.3.2.4 test difference, napparent thermoelectric differenceattributable to mated connectors observed by the test procedureof this specification.4. Significance and Use4.1 The widespread use of thermocouple connectors re-quires standardization of mati
12、ng dimensions and performancecharacteristics.4.2 This specification describes miniaturized thermocoupleconnector dimensions and capabilities and includes test proce-dures suitable for evaluating the performance of a particularspecimen or design. The tests described are not intended for1This specific
13、ation is under the jurisdiction of ASTM Committee E20 onTemperature Measurement and is the direct responsibility of Subcommittee E20.04on Thermocouples.Current edition approved Nov. 1, 2010. Published December 2010. Originallyapproved in 1995. Last previous edition approved in 2005 as E1684 05. DOI:
14、10.1520/E1684-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.TABLE 1 RatingsCharacteristic min maxOperati
15、ng temperature 0F (-18C) 300F (150C)Contact resistance (each leg) . 0.04 VInsulation resistance at room temperature 107V .Insulation resistance at 300 F (150 C) 106V .Test difference . 62F (61.1C)Repeated coupling cycles (coupled oruncoupled)25 .Service life 5000 h .Withdraw force 8 oz .1Copyright A
16、STM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.routine inspection or rapid testing of large groups of connectorsor for quality control purposes.5. Classification5.1 Plugs or Jacks:5.1.1 Connectors shall be constructed as either plugs orjacks, a
17、nd these two forms shall be designed to connect witheach other.5.1.2 Plug connectors shall have two external prong con-tacts of differing sizes to prevent improper mating. Thenegative prong shall be the wider, as indicated in Table 2 andFig. 1.5.1.3 Jack connector shall have two internal socket cont
18、actssized and spaced to receive and accommodate the prongcontacts of the mating plug. Jack connectors shall also includea means of producing and maintaining sufficient contactpressure to meet all the other requirements of this specification.5.2 ANSI/ASTM Type:5.2.1 Connectors shall be produced in ve
19、rsions to matcheach of the standardized ANSI/ASTM thermocouple types asgiven in Table 3.5.2.2 The insert materials of each plug and jack shall havethermoelectric properties conforming to the characteristics ofthe corresponding thermocouple type as given in SpecificationE230 over the temperature rang
20、e specified in Table 1.5.2.3 Calibration conformance and gradient testing is notapplicable to Type B thermoelectrically neutral (Cu/Cu) con-nectors.6. Ordering Information6.1 Orders for connectors under this specification shallinclude the following:6.1.1 Quantity of plugs or jacks (specify which);6.
21、1.2 ANSI/ASTM calibration thermocouple type and colorcode per Table 3. Connectors shall be supplied to the ASTMcolor code unless otherwise specified;6.1.3 Any optional accessories that may be required, such asthose listed in 7.4.3;6.1.4 Special testing requirements; and6.1.5 Requirements for certifi
22、cates of conformance to thespecifications or reports of the results of any required testing.7. Materials and Manufacture7.1 Body:7.1.1 The dimensions of the connector bodies shall fallwithin the limits given in Table 2.7.1.2 The connector body shall be made of an insulatingmaterial capable of contin
23、uous use at any temperature between0F (-18C) and 300F (150C) for the service life given inTable 1, without losing its ability to conform to this specifica-tion.7.1.3 The connector bodies shall be colored in accordancewith the color code given in Table 3 to provide rapid andpermanent identification o
24、f the thermocouple calibration withwhich it is designed to be used. Each plug and jack shall bepermanently marked with a symbol or symbols to identifypositive and negative conductor inserts. All connectors shallbear the suppliers name or other means of source identifica-tion, unless otherwise specif
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME16842010STANDARDSPECIFICATIONFORMINIATURETHERMOCOUPLECONNECTORS 小型 热电偶 连接器 标准规范 PDF

链接地址:http://www.mydoc123.com/p-529231.html