1、Designation: E 1684 05Standard Specification forMiniature Thermocouple Connectors1This standard is issued under the fixed designation E 1684; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in pa
2、rentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers separable single-circuit minia-ture thermocouple connectors with two flat pins. Connectorscovered by this specification
3、must be rated for continuous useto at least 300 F (150 C), but they may optionally be ratedhigher.1.2 This specification does not cover multiple-circuit con-nectors, multi-pin connectors, standard size connectors, orconnectors intended primarily for panel mounting. High-temperature connectors (for e
4、xample, those designed for con-tinuous use at temperatures significantly above approximately500 F (260 C) are not intended to be covered by thisspecification.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.4 The f
5、ollowing precautionary statement pertains only tothe test methods portion, Section 9, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and h
6、ealthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 The following documents of the latest issue form a partof this specification to the extent referenced herein. In case ofconflict between this specification and another referenceddocument
7、, this specification shall take precedence.2.2 ASTM Standards:2E 230 Specification and Temperature-Electromotive Force(EMF) Tables for Standardized ThermocouplesE 344 Terminology Relating to Thermometry and Hydrom-etry3. Terminology3.1 DefinitionsThe definitions given in TerminologyE 344 shall apply
8、.3.2 Definitions of Terms Specific to This Standard:3.2.1 connector pair, nassembly consisting of a plug anda jack, each having both positive and negative inserts, that willconnect two parts of an electrical circuit and provide a meansof physically disconnecting the two parts without the use oftools
9、.3.2.2 contact insert, nmetallic conductor assemblies that,when installed in connector bodies, provide connections be-tween two parts of an electrical circuit. Plug connectors willcontain projecting prong contacts, while jack connectors willcontain recessed socket or receptacle contacts.3.2.3 servic
10、e life, ninterval of time that a connectorassembly will be put to use and retain all physical andthermoelectric properties.3.2.4 test difference, napparent thermoelectric differenceattributable to mated connectors observed by the test procedureof this specification.4. Significance and Use4.1 The wid
11、espread use of thermocouple connectors re-quires standardization of mating dimensions and performancecharacteristics.4.2 This specification describes miniaturized thermocoupleconnector dimensions and capabilities and includes test proce-dures suitable for evaluating the performance of a particularsp
12、ecimen or design. The tests described are not intended forroutine inspection or rapid testing of large groups of connectorsor for quality control purposes.5. Classification5.1 Plugs or Jacks:5.1.1 Connectors shall be constructed as either plugs orjacks, and these two forms shall be designed to conne
13、ct witheach other.5.1.2 Plug connectors shall have two external prong con-tacts of differing sizes to prevent improper mating. Thenegative prong shall be the wider, as indicated in Table 1.5.1.3 Jack connector shall have two internal socket contactssized and spaced to receive and accommodate the pro
14、ngcontacts of the mating plug. Jack connectors shall also include1This specification is under the jurisdiction of ASTM Committee E20 onTemperature Measurement and is the direct responsibility of Subcommittee E20.04on Thermocouples.Current edition approved May 1, 2005. Published May 2005. Originallya
15、pproved in 1995. Last previous edition approved in 2000 as E 1684 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM
16、website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.a means of producing and maintaining sufficient contactpressure to meet all the other requirements of this specification.5.2 ANSI/ASTM Type:5.2.1 Connectors shall be produced in
17、 versions to matcheach of the standardized ANSI/ASTM thermocouple types asgiven in Table 2.5.2.2 The insert materials of each plug and jack shall havethermoelectric properties conforming to the characteristics ofthe corresponding thermocouple type as given in SpecificationE 230 over the temperature
18、range specified in Table 3.5.2.3 Calibration conformance and gradient testing is notapplicable to Type B thermoelectrically neutral (Cu/Cu) con-nectors.6. Ordering Information6.1 Orders for connectors under this specification shallinclude the following:6.1.1 Quantity of plugs or jacks (specify which
19、);6.1.2 ANSI/ASTM calibration thermocouple type (seeTable 2);6.1.3 Any optional accessories that may be required, such asthose listed in 7.4.3;6.1.4 Special testing requirements; and6.1.5 Requirements for certificates of conformance to thespecifications or reports of the results of any required test
20、ing.7. Materials and Manufacture7.1 Body:7.1.1 The dimensions of the connector bodies shall fallwithin the limits given in Table 1.7.1.2 The connector body shall be made of an insulatingmaterial capable of continuous use at any temperature between0 F (18 C) and 300 F (150 C) for the service life giv
21、en inTable 3, without losing its ability to conform to this specifica-tion.7.1.3 The connector bodies shall be colored in accordancewith the color code given in Table 2 to provide rapid andpermanent identification of the thermocouple calibration withwhich it is designed to be used. Each plug and jac
22、k shall bepermanently marked with a symbol or symbols to identifypositive and negative conductor inserts. All connectors shallbear the suppliers name or other means of source identifica-tion, unless otherwise specified in the purchasing documents.7.1.4 An insulating barrier shall be incorporated int
23、o eachconnector body to prevent inadvertent contact between ther-moelements or wires.7.2 Inserts:7.2.1 Contact inserts shall be fabricated of paired materialsof the same thermocouple type as the thermocouple with whichthey are to be used.7.2.2 The inside width and depth of the jack connector shallbe
24、 such as to receive the corresponding plug prong smoothlyand easily when inserted.7.2.3 The force required for complete disengagement shallconform to the requirements of Table 3.7.3 Construction and Assembly:7.3.1 Wire attachment shall be by means of a screw orclamp suitable for use with wire diamet
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME16842005STANDARDSPECIFICATIONFORMINIATURETHERMOCOUPLECONNECTORS 小型 热电偶 连接器 标准规范 PDF

链接地址:http://www.mydoc123.com/p-529230.html