ASTM E299-2017a red 3125 Standard Test Method for Trace Amounts of Peroxides In Organic Solvents《有机溶液中痕量过氧化物的标准试验方法》.pdf
《ASTM E299-2017a red 3125 Standard Test Method for Trace Amounts of Peroxides In Organic Solvents《有机溶液中痕量过氧化物的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E299-2017a red 3125 Standard Test Method for Trace Amounts of Peroxides In Organic Solvents《有机溶液中痕量过氧化物的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E299 17E299 17aStandard Test Method forTrace Amounts of Peroxides In Organic Solvents1This standard is issued under the fixed designation E299; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This test method2,3 covers organic solvents c
3、ontaining active oxygen in the range from 5 to 80 g/g (ppm) or higher. Byusing a special reaction-absorption cell, the test method can be extended to cover the range from 0 to 5 ppm. The test method canbe used to determine numerous peroxide classes of varying reactivity such as hydroperoxides, diacy
4、l peroxides, diaroyl peroxides,peresters, and ketone peroxides. The stable di-tert-alkyl peroxides do not react under the conditions of analysis.1.2 Solvents that can be analyzed successfully include saturated and aromatic hydrocarbons, alcohols, ethers, ketones, andesters. In addition, the test met
5、hod is applicable to olefinic solvents and to certain compounds that contain , and conjugatedunsaturation. Solid samples that are soluble in the acetic acid-chloroform solvent also can be analyzed.1.3 Review the current Safety Data Sheets (SDS) for detailed information concerning toxicity, first aid
6、 practices, and safetyprecautions.1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.1.5 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of theuser of this
7、 standard to establish appropriate safety and health practices and determine the applicability of regulatory limitationsprior to use.1.5 Review the current Safety Data Sheets (SDS) for detailed information concerning toxicity, first aid practices, and safetyprecautions.1.6 This international standar
8、d was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referen
9、ced Documents2.1 ASTM Standards:4D1193 Specification for Reagent WaterD6809 Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related MaterialsE180 Practice for Determining the Precision of ASTM Methods for Analysis and Testing of Industrial and Specialty Chemi
10、cals(Withdrawn 2009)53. Summary of Test Method3.1 A sample is dissolved in a mixture of acetic acid and chloroform. The solution is deaerated and potassium iodide reagentsolution is added. The mixture is allowed to react in the dark for 1 h, thereby releasing an equivalent amount of iodine. Theabsor
11、bance of the solution is measured at 470 nm and the amount of active oxygen present in the sample is determined by referenceto a calibration curve prepared from iodine.1 This test method is under the jurisdiction of ASTM Committee D16 on Aromatic Hydrocarbons Aromatic, Industrial, Specialty and Rela
12、ted Chemicals and is the directresponsibility of Subcommittee D16.15 on Industrial and Specialty General Standards.Current edition approved Feb. 1, 2017July 1, 2017. Published February 2017July 2017. Originally approved in 1966. Last previous edition approved in 20082017 asE299 08.E299 17. DOI: 10.1
13、520/E0299-17.10.1520/E0299-17a.2 Banerjee, D. K., and Budke, C. C., Analytical Chemistry, ANCHAM, Vol 36, 1964, pp. 792796.3 Banerjee, D. K., and Budke, C. C., Analytical Chemistry, ANCHAM, Vol 36, 1964, pp. 23672368.4 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM
14、 Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.5 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and is intended only
15、 to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versio
16、nof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2 For samples containing 0 to 5 g/g (pp
17、m) active oxygen, a special reaction-absorption cell is employed. The sample isde-aerated and the reaction is carried out within the cell.Absorbance measurements are made at 410 nm to increase the sensitivity.4. Significance and Use4.1 Dilute solutions of peroxides in various organic solvents freque
18、ntly are used as catalysts or reaction initiators. Peroxides alsocan be formed through autoxidation in certain classes of compounds including ethers, acetals, dienes, and alkylaromatichydrocarbons and present a potential safety hazard. This test method provides a procedure for determining the peroxi
19、de or activeoxygen level.5. Interferences5.1 Oxidizing or reducing substances present in the sample will interfere. Colored solutions can be analyzed if an absorbancecorrection is made.6. Apparatus6.1 SpectrophotometerBeckman Model DU or equivalent with matched 1-cm cells.6.2 Special Reaction-Absorp
20、tion Cell (Fig. 1)When this cell is used, the regular Beckman cell carriage shall be replaced withthe attachment provided for measuring the absorbance in test tubes.7. Reagents7.1 Purity of ReagentsReagent grade chemicals shall be used in all tests. Unless otherwise indicated, it is intended that al
21、lreagents shall conform to the specifications of the Committee on Analytical Reagents of the American Chemical Society, wheresuch specifications are available.6 Other grades may be used, provided it is first ascertained that the reagent is of sufficiently highpurity to permit its use without lesseni
22、ng the accuracy of the determination.7.2 Purity of WaterUnless otherwise indicated, references to water shall be understood to mean Type II or Type III reagentwater conforming to Specification D1193.7.3 Acetic Acid-Chloroform Solvent (2 + 1)Mix 2 volumes of acetic acid with 1 volume of chloroform.7.
23、4 Acetic Acid-Chloroform Solvent (Containing Approximately 4 % Water)Add 40 mL of water to 1 L of solvent preparedas described in 7.3.7.5 Iodine.7.6 Nitrogen Cylinder.6 Reagent Chemicals, American Chemical Society Specifications, American Chemical Society, Washington, DC. For suggestions on the test
24、ing of reagents not listed bythe American Chemical Society, see Analar Standards for Laboratory Chemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeia and NationalFormulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville, MD.FIG. 1 Absorption Cell for Low-Active OxygenE2
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME2992017ARED3125STANDARDTESTMETHODFORTRACEAMOUNTSOFPEROXIDESINORGANICSOLVENTS 有机 溶液 痕量 过氧化物 标准 试验

链接地址:http://www.mydoc123.com/p-527346.html