1、Designation: D 7297 06Standard Practice forEvaluating Residential Indoor Air Quality Concerns1This standard is issued under the fixed designation D 7297; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This standard practice describes procedures for evaluat-ing indoor air quality (IAQ) concerns in residential buildings.1.2 The practic
3、e primarily addresses IAQ concerns encoun-tered in single-family detached and attached (for example,townhouse or duplex design) residential buildings. Limitedguidance is also included for low- and high-rise multifamilydwellings.1.3 The IAQ evaluation procedures are comprised of inter-views with the
4、homeowner or resident(s) (including telephoneinterviews and face-to-face meetings) and on-site investiga-tions (including walk-through, assessment, and measure-ments). For practicality in application, these procedures aredividing into three separate phases.1.4 The procedures described in this standa
5、rd practice areaimed at identifying potential causes contributing to the IAQconcern. Such findings should become a basis for recommend-ing corrective measures. This standard practice does notdescribe problem resolution or corrective measures and thestandard is not intended to evaluate the impact of
6、correctivemeasures.1.5 Implementation of procedures given in this standardrequires the investigator (or investigative team) to have ad-equate background in several areas: general principles of IAQ;interviewing techniques; building design and constructionpractices; basic understanding of heating and
7、cooling systemsand appliances; use of IAQ measurement equipment; interpre-tation of IAQ data; and technical report writing.1.6 Although many elements described in this standardpractice may be useful in training of IAQ investigators, itshould not be used as the sole basis for specifying orconducting
8、such training.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.
9、For additionalsafety precautionary information, see Section 6.2. Referenced Documents2.1 ASTM Standards:2D 1356 Terminology Relating to Sampling and Analysis ofAtmospheresD 1357 Practice for Planning the Sampling of the AmbientAtmosphereD 4861 Practice for Sampling and Selection of AnalyticalTechniq
10、ues for Pesticides and Polychlorinated Biphenylsin AirD 4947 Test Method for Chlordane and Heptachlor Resi-dues in Indoor AirD 5197 Test Method for Determination of Formaldehydeand Other Carbonyl Compounds in Air (Active SamplerMethodology)D 5438 Practice for Collection of Floor Dust for ChemicalAna
11、lysisD 5466 Test Method for Determination of Volatile OrganicChemicals in Atmospheres (Canister Sampling Methodol-ogy)D 5952 Guide for Inspecting Water Systems for Legionellaeand Investigating Possible Outbreaks of Legionellosis(Legionnaires Disease or Pontiac Fever)D 5955 Test Methods for Estimatin
12、g Contribution of Envi-ronmental Tobacco Smoke to Respirable Suspended Par-ticles Based on UVPM and FPMD 6196 Practice for Selection of Sorbents, Sampling, andThermal Desorption Analysis Procedures for Volatile Or-ganic Compounds in AirD 6271 Test Method for Estimating Contribution of Envi-ronmental
13、 Tobacco Smoke to Respirable Suspended Par-ticles Based on SolanesolD 6333 Practice for Collection of Dislodgeable PesticideResidues from FloorsD 6345 Guide for Selection of Methods for Active, Integra-tive Sampling of Volatile Organic Compounds in AirE 241 Guide for Limiting Water-Induced Damage to
14、 Build-ings1This practice is under the jurisdiction of ASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.05 on Indoor Air.Current edition approved Dec. 1, 2006. Published January 2007.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact
15、ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.E 609 Terminology Relating
16、 to PesticidesE 620 Practice for Reporting Opinions of Scientific orTechnical ExpertsE 741 Test Method for Determining Air Change in a SingleZone by Means of a Tracer Gas DilutionE 779 Test Method for Determining Air Leakage Rate byFan PressurizationE 943 Terminology Relating to Biological Effects a
17、nd En-vironmental FateE 1186 Practices forAir Leakage Site Detection in BuildingEnvelopes and Air Barrier SystemsE 1554 Test Methods for Determining ExternalAir Leakageof Air Distribution Systems by Fan PressurizationE 1827 Test Methods for Determining Airtightness ofBuildings Using an Orifice Blowe
18、r DoorE 1998 Guide for Assessing Depressurization-InducedBackdrafting and Spillage from Vented Combustion Appli-ancesE 2128 Guide for Evaluating Water Leakage of BuildingWalls2.2 Other Documents:ASHRAE 62.2-2004 Ventilation and Acceptable Indoor AirQuality in Low-Rise Residential Buildings3ASHRAE 11
19、9 Air Leakage Performance for DetachedSingle-Family Residential Buildings33. Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice, refer to Terminologies D 1356, E 609, and E 943.3.2 Definitions of Terms Specific to This Standard:3.2.1 hypothesis, na provisional theory set forth
20、 to ex-plain certain indoor air quality problems or phenomena.3.2.2 pause point, nan interim step within a proceduralsequence designed to allow subsequent actions to be based onthe analysis and evaluation of recently collected data.3.2.3 stack effect, nbuoyancy associated with the indoor-outdoor tem
21、perature differences.4. Summary of Practice4.1 IAQ-based complaints and problems in residentialbuildings include discomfort and health symptoms arising fromexposure to indoor air pollutants, as well as unacceptableindoor environmental conditions such as mold growth orlingering odors.4.2 This practic
22、e describes procedures for the systematicinvestigation of IAQ concerns using an iterative process thatinvolves problem definition, information gathering, formula-tion of hypotheses, measurements (if necessary), and problemidentification. It may include testing hypotheses by takingactions and evaluat
23、ing their impact on the IAQ concern.4.3 To enhance the effectiveness and management of anIAQ investigation, it is often conducted in three separatephases: (1) initial meeting with the building owner andwalk-through, (2) detailed assessment of the building and itssystems, and (3) pollutant measuremen
24、ts, if necessary. Suchphased investigations also allow informing the building owneror the cognizant party of the progress and seeking approval forensuing work.4.4 Major steps recommended for IAQ investigations in-clude an initial interview with the building owner or occupant,on-site meeting and walk
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD72972006STANDARDPRACTICEFOREVALUATINGRESIDENTIALINDOORAIRQUALITYCONCERNS 评估 住宅 室内 空气质量 影响 标准 实施

链接地址:http://www.mydoc123.com/p-525070.html