ASTM D6290-2005e1 1250 Standard Test Method for Color Determination of Plastic Pellets《塑料颗粒颜色测定的标准试验方法》.pdf
《ASTM D6290-2005e1 1250 Standard Test Method for Color Determination of Plastic Pellets《塑料颗粒颜色测定的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6290-2005e1 1250 Standard Test Method for Color Determination of Plastic Pellets《塑料颗粒颜色测定的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6290 051Standard Test Method forColor Determination of Plastic Pellets1This standard is issued under the fixed designation D6290; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in
2、parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEAdded research report information to Section 10 editorially in September 2010.1. Scope*1.1 This test method is intended primarily for the instru-mental
3、measurement of the degree of yellowness (or change ofdegree of yellowness) under daylight illumination of homoge-neous, nonfluorescent, nearly-colorless transparent or nearly-white translucent or opaque plastics. The measurement is madeon pellets and based on tristimulus values obtained with aspectr
4、ophotometer or colorimeter.1.2 This test method is applicable to the color analysis ofplastic pellets. Each material may have unique characteristicsthat determine the color values.1.3 This procedure outlines a method to determine colormeasurements, such as Yellowness Index, CIE X, Y, Z, andHunter L,
5、 a, b, or CIE L*, a*, b*.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations pri
6、or to use.NOTE 1There is no equivalent ISO Standard.2. Referenced Documents2.1 ASTM Standards:2D883 Terminology Relating to PlasticsD2244 Practice for Calculation of Color Tolerances andColor Differences from Instrumentally Measured ColorCoordinatesE179 Guide for Selection of Geometric Conditions fo
7、rMeasurement of Reflection and Transmission Properties ofMaterialsE284 Terminology of AppearanceE308 Practice for Computing the Colors of Objects byUsing the CIE SystemE313 Practice for Calculating Yellowness and WhitenessIndices from Instrumentally Measured Color CoordinatesE691 Practice for Conduc
8、ting an Interlaboratory Study toDetermine the Precision of a Test MethodE1331 Test Method for Reflectance Factor and Color bySpectrophotometry Using Hemispherical GeometryE1347 Test Method for Color and Color-Difference Mea-surement by Tristimulus ColorimetryE1349 Test Method for Reflectance Factor
9、and Color bySpectrophotometry Using Bidirectional (45:0 or 0:45)Geometry3. Terminology3.1 Definitions Refer to Terminologies D883 and E284for definitions of terms used in this test method.4. Significance and Use4.1 Before proceeding with this test method, referenceshould be made to the specification
10、 of the material being tested.Any test specimen preparation, conditioning, dimensions, ortesting parameters, or a combination thereof, covered in thematerials specification shall take precedence over those men-tioned in this test method. If there are no material specifica-tions, then default conditi
11、ons apply.NOTE 2Some materials, such as polyamide (nylon), can be cooledvery differently during the production of the pellets. This variation in thecooling of the pellets can result in different levels of crystallinity in thepellets only. More crystalline nylons will be more opaque than amorphousnyl
12、ons. This will result in differences in pellet opacity. The pellet shape isindependent of the crystallinity of the material. This variation in pelletappearance, due to varying levels of crystallinity, does not affect finalproperties.NOTE 3This test method should not be used for general materialspeci
13、fications.4.2 This test method describes a technique useful for mak-ing color comparisons of resins in pellet form that is fast andconvenient as it does not require preparation, such as moldingor extruding specimens. The test method shall be used only tocompare specimens of similar pellet shape, siz
14、e, texture, and1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.40 on Optical Properties.Current edition approved April 1, 2005. Published June 2005. Originallyapproved in 1998. Last previous edition approved in 1998 as
15、 D6290 - 981. DOI:10.1520/D6290-05E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes
16、section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.degree of translucency. For example, translucent disc-shapedpellets should be compared to translucent disc-shaped pellets,not with opaque, rec
17、tangular shaped pellets.4.3 Exact measurements of resin pellet color may not bedirectly related to the color of the final cast, molded orextruded product due to the multitude of variables, such asproducing variables, methods, and pellet shape and size. Colormeasurements can be useful for comparing r
18、esins in pellet formwhen all samples are similar in shape and size.4.4 A three-number tristimulus system is necessary to quan-tify color completely and precisely. The general method used inthis procedure measures color using the CIE Systems describedin Practice E308, Test Method D2244, the CIE 1976
19、(X, Y, Z)system, and, the CIELAB 1976 color space.34.5 Individual components of the tristimulus measurementsuch as CIE Y (Luminance), Hunter L, a, b, or CIE L*, a*, b*values or other useful metrics like yellowness index can beused to describe color attributes of materials. This test methoddescribes
20、a standard procedure on how these measurements aremade.5. Interferences5.1 Comparisons of color measurements can only be madeif the material is the same, the pellet cut, size and shape areessentially the same and the test instrument is the same typeand within the same group. (See 6.2 and Section 10
21、and TablesA and B for instrument differences.)6. Apparatus6.1 Apparatus may be spectrophotometer, or tristimuluscolorimeter, conforming to Guide E179.6.2 There are several different optical geometries currentlybeing used for measuring color. It is important that similaroptical geometries be used if
22、results are to be compared. Theseare designated as Groups defined as follows:6.2.1 Group ISpectrophotometer with 45 to 52-mm portwith 0/45 directional geometry. See Test Methods E1347 andE1349.6.2.2 Group IIColorimeter with 52-mm port with 45/0directional geometry. See Test Methods E1347 and E1349.6
23、.2.3 Group IIISphere with minimum of 25-mm port witha nominal 0/diffuse geometry. See Test Methods E1331 andE1347.6.2.4 Group IVSphere with minimum of 25-mm port witha nominal diffuse/0 geometry. See Test Methods E1331 andE1347.6.3 There may be other optical geometries being used forthis test method
24、, which should be added if being used andbrought to our attention as this procedure is being evaluated.6.4 Calibrated tiles, for instrument standardization.6.5 Glass (clear), specimen cell at least 60-mm 212-in.diameter and a minimum of 50-mm depth and black samplecover of sufficient size to prevent
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD62902005E11250STANDARDTESTMETHODFORCOLORDETERMINATIONOFPLASTICPELLETS 塑料颗粒 颜色 测定 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-522076.html