《ASTM D6096-2007 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable 90 &176 C Operation《工作温度90C的电线和电缆用聚氯乙烯绝缘性的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6096-2007 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable 90 &176 C Operation《工作温度90C的电线和电缆用聚氯乙烯绝缘性的标准规范》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6096 07An American National StandardStandard Specification forPoly(Vinyl Chloride) Insulation for Wire and Cable, 90 COperation1This standard is issued under the fixed designation D 6096; the number immediately following the designation indicates the year oforiginal adoption or, in th
2、e case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers a thermoplastic insulation ofpoly (vinyl chloride) or the
3、copolymer of vinyl chloride andvinyl acetate. This insulation is recommended for use atconductor temperatures not in excess of 90 C.1.2 Depending on the thickness of the insulation, the maxi-mum voltage used, and whether the location is wet or dry, thisinsulation is acceptable for use in 300 V (dry)
4、 and 600 V (wetor dry) power and control circuits.1.3 This insulation has potential low-temperature installa-tion limitations. Consult the manufacturer for specific recom-mendations for installation.1.4 Whenever two sets of values are presented, in differentunits, the values in the first set are the
5、 standard, while those inparentheses are for information only.1.5 In many instances the insulation material cannot betested unless it has been formed around a conductor or cable.Therefore, tests are done on insulated wire or cable in thisspecification solely to determine the relevant property of the
6、insulation material and not to test the conductor or completedcable.2. Referenced Documents2.1 ASTM Standards:2D 1711 Terminology Relating to Electrical InsulationD 2633 Test Methods for Thermoplastic Insulations andJackets for Wire and Cable3. Terminology3.1 Definitions: For definitions of terms us
7、ed in this speci-fication, refer to Terminology D 1711.3.2 Definitions of Terms Specific to This Standard:3.2.1 aging (act of), nexposure of materials to air or oil ata temperature and for an interval of time as required in Table1.4. Physical Properties4.1 The insulation shall conform to the require
8、ments forphysical properties prescribed in Table 1. (See Table 2 foroptional oil resistance requirements.)5. Electrical Requirements5.1 Perform the ac voltage, insulation resistance, and dcvoltage tests in that order when any of these tests are required.The sequence for other testing is not specifie
9、d.5.2 AC Voltage Test Test the insulated conductor at the acwithstand voltage as specified in Table 3. Unless otherwisespecified, omit this test if the dc withstand voltage testdescribed in 5.4 is performed.1This specification is under the jurisdiction of ASTM CommitteeD09 onElectrical and Electroni
10、c Insulating Materials and is the direct responsibility ofSubcommittee D09.18 on Solid Insulations, Non-Metallic Shieldings and Coveringsfor Electrical and Telecommunication Wires and Cables.Current edition approved Oct. 1, 2007. Published October 2007. Originallyapproved in 1997. Last previous edit
11、ion approved in 2002 as D 609602.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.TABLE 1 Physical Properties
12、Requirements for InsulationUnaged requirements:Tensile strength, min, psi (MPa) 2000 (13.8)Elongation at rupture, min, % 150Aged requirements:After air oven test at 1366 1 C for 168 h:Tubular Specimens - up to size AWG 6 (13.3mm2)Tensile strength, min, percent of unaged value: 70Elongation at ruptur
13、e, min, percent of unagedvalue:65Buffed die-cut Specimens - sizes AWG 6 andlargerTensile strength, min, percent of unaged value: 70Elongation at rupture, min, percent of unagedvalue:45Heat shock, 121 6 1 C no cracksHeat distortion, 1216 1 C, max, percent decrease 25Vertical flame test, after five 15
14、-s applications: passesOil resistance:After oil immersion at 70 6 1Cfor4h:Tubular Specimens - up to size AWG 6 (13.3mm2)Tensile strength, min, percent of unaged value 85Elongation, min, percent of unaged value 85Buffed die-cut Specimens - sizes AWG 6 andlargerTensile strength, min, percent of unaged
15、 value 80Elongation, min, percent of unaged value 60Cold bend test, 306 1 C for 1 h no cracks1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.3 Insulation Resistance:
16、5.3.1 Insulated conductors in SizesAWG 14 (2.08 mm2) andlarger shall have an insulation resistance of at least thatcorresponding to a constant of 2000 MV-1000 ft at 60 F (15.6C).5.3.2 If the temperature at the time the measurement wasmade differs from 60 F (15.6 C), correct the insulationresistance
17、to 60F by multiplying the measured value by theproper correction factor from Table number 1 of Test MethodsD 2633.5.4 DC Voltage Test Upon completion of the insulationresistance test, test each non-shielded insulated conductor for 5min at a dc withstand voltage that is three times the ac testvoltage
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD60962007STANDARDSPECIFICATIONFORPOLYVINYLCHLORIDEINSULATIONFORWIREANDCABLE90176COPERATION 工作温度 90

链接地址:http://www.mydoc123.com/p-521521.html