ASTM D5769-2015 red 0838 Standard Test Method for Determination of Benzene Toluene and Total Aromatics in Finished Gasolines by Gas Chromatography Mass Spectrometry《采用气相色谱 质谱法测定成品汽.pdf
《ASTM D5769-2015 red 0838 Standard Test Method for Determination of Benzene Toluene and Total Aromatics in Finished Gasolines by Gas Chromatography Mass Spectrometry《采用气相色谱 质谱法测定成品汽.pdf》由会员分享,可在线阅读,更多相关《ASTM D5769-2015 red 0838 Standard Test Method for Determination of Benzene Toluene and Total Aromatics in Finished Gasolines by Gas Chromatography Mass Spectrometry《采用气相色谱 质谱法测定成品汽.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5769 10 (Reapproved 2015)D5769 15Standard Test Method forDetermination of Benzene, Toluene, and Total Aromatics inFinished Gasolines by Gas Chromatography/MassSpectrometry1This standard is issued under the fixed designation D5769; the number immediately following the designation indica
2、tes the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This test method covers the determina
3、tion of benzene, toluene, other specified individual aromatic compounds, and totalaromatics in finished motor gasoline, including gasolines containing oxygenated blending components, by gas chromatography/mass spectrometry (GC/MS).1.2 This test method has been tested for the following concentration
4、ranges, in liquid volume percent, for the followingaromatics: benzene, 0.1 % to 4 %; toluene, 1 % to 13 %; and total (C6 to C12) aromatics, 10 % to 42 %. The round-robin studydid not test the method for individual hydrocarbon process streams in a refinery, such as reformates, fluid catalytic cracked
5、naphthas, and so forth, used in the blending of gasolines.1.3 Results are reported to the nearest 0.01 % for benzene and 0.1 % for the other aromatics by liquid volume.1.4 This test method includes a relative bias section for EPA spark-ignition engine fuel benzene regulations reporting based onPract
6、ice D6708 accuracy assessment between Test Method D5769 and Test Method D3606 as a possible Test Method D5769alternative to Test Method D3606. The Practice D6708 derived correlation equation is only applicable for blended fuels in thebenzene concentration range from 0.0 % to 2.50 % by volume as meas
7、ured by Test Method D5769. The applicable Test MethodD3606 range for benzene is from 0.0 % to 2.47 % by volume as reported by Test Method D3606.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not pur
8、port to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to its use.2. Referenced Documents2.1 ASTM Standards:2
9、D1298 Test Method for Density, Relative Density, or API Gravity of Crude Petroleum and Liquid Petroleum Products byHydrometer MethodD3606 Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline by Gas Chromatog-raphyD4052 Test Method for Density, Relative Density
10、, and API Gravity of Liquids by Digital Density MeterD4057 Practice for Manual Sampling of Petroleum and Petroleum ProductsD4307 Practice for Preparation of Liquid Blends for Use as Analytical StandardsD6708 Practice for Statistical Assessment and Improvement of Expected Agreement Between Two Test M
11、ethods that Purportto Measure the Same Property of a Material3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 aromaticany hydrocarbon compound containing a benzene or naphthalene ring.1 This test method is under the jurisdiction ofASTM Committee D02 on Petroleum Products, Liqui
12、d Fuels, and Lubricants and is the direct responsibility of SubcommitteeD02.04.0M on Mass Spectroscopy.Current edition approved June 1, 2015Dec. 1, 2015. Published July 2015December 2015. Originally approved in 1995. Last previous edition approved in 20102015 asD5769 10.D5769 10 (2015). DOI: 10.1520
13、/D5769-10R15.10.1520/D5769-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM st
14、andard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all ca
15、ses only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.2 calibrat
16、ed aromatic componentthe individual aromatic components that have a specific calibration.3.1.3 cool on-column injectorin gas chromatography, a direct sample introduction system that is set at a temperature at orbelow the boiling point of solutes or solvent on injection and then heated at a rate equa
17、l to or greater than the column. Normallyused to eliminate boiling point discrimination on injection or to reduce adsorption on glass liners within injectors, or both. Thesample is injected directly into the head of the capillary column tubing.3.1.4 open split interfaceGC/MS interface used to mainta
18、in atmospheric pressure at capillary column outlet and to eliminatemass spectrometer vacuum effects on the capillary column. Can be used to dilute the sample entering the mass spectrometer tomaintain response linearity.3.1.5 reconstructed ion chromatogram (RIC)a limited mass chromatogram representin
19、g the intensities of ion massspectrometric currents for only those ions having particular mass to charge ratios. Used in this test method to selectively extractor identify aromatic components in the presence of a complex hydrocarbon matrix, such as gasoline.3.1.6 retention gapin gas chromatography,
20、refers to a deactivated precolumn which acts as a zone of low retention power forreconcentrating bands in space. The polarity of the precolumn must be similar to that of the analytical column.3.1.7 split ratioin capillary gas chromatography, the ratio of the total flow of carrier gas to the sample i
21、nlet versus the flowof the carrier gas to the capillary column, expressed by:split ratio5S1C!/C (1)where:S = flow rate at the splitter vent, andC = flow rate at the column outlet.3.1.8 total ion chromatogram (TIC)mass spectrometer computer output representing either the summed intensities of allscan
22、ned ion currents or a sample of the current in the ion beam for each spectrum scan plotted against the corresponding spectrumnumber. Generally, it can be correlated with a flame ionization detector chromatogram.3.1.9 uncalibrated aromatic componentindividual aromatics for which a calibration is not
23、available. These components areestimated from the calibration of several calibrated aromatic components.3.1.10 wall coated open tubular (WCOT)a type of capillary column prepared by coating or bonding the inside wall of thecapillary with a thin film of stationary phase.4. Summary of Test Method4.1 A
24、gas chromatograph equipped with a dimethylpolysiloxane WCOT column is interfaced to a fast scanning massspectrometer that is suitable for capillary column GC/MS analyses. The sample is injected either through a capillary splitter portor a cool-on-column injector capable of introducing a small sample
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD57692015RED0838STANDARDTESTMETHODFORDETERMINATIONOFBENZENETOLUENEANDTOTALAROMATICSINFINISHEDGASOLINESBYGASCHROMATOGRAPHYMASSSPECTROMETRY

链接地址:http://www.mydoc123.com/p-520635.html