ASTM D4212-2010 Standard Test Method for Viscosity by Dip-Type Viscosity Cups《浸式粘度杯测定粘度的标准试验方法》.pdf
《ASTM D4212-2010 Standard Test Method for Viscosity by Dip-Type Viscosity Cups《浸式粘度杯测定粘度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4212-2010 Standard Test Method for Viscosity by Dip-Type Viscosity Cups《浸式粘度杯测定粘度的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4212 10Standard Test Method forViscosity by Dip-Type Viscosity Cups1This standard is issued under the fixed designation D4212; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in par
2、entheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of viscosityof paints, varnishes, lacquers, inks, and related liquid materialsby dip-type viscosity cups.
3、This test method is recommendedfor viscosity control work within one plant or laboratory andshould be used to check compliance with specifications onlywhen sufficient controls have been instituted to ensure ad-equate comparability of results.1.2 Viscosity cups are designed for testing of Newtonianan
4、d near-Newtonian liquids. If the test material is non-Newtonian, for example, shear-thinning or thixotropic, anothermethod, such as Test Methods D2196, should be used. Undercontrolled conditions, comparisons of the viscosity of non-newtonian materials may be helpful, but viscosity determina-tion met
5、hods using controlled shear rate or shear stress arepreferred.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is t
6、heresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1200 Test Method for Viscosity by Ford Viscosity CupD2196 Test Methods for Rheologic
7、al Properties of Non-Newtonian Materials by Rotational (Brookfield type) Vis-cometerD4287 Test Method for High-Shear Viscosity Using aCone/Plate ViscometerE1 Specification for ASTM Liquid-in-Glass Thermometers3. Terminology3.1 Definitions:3.1.1 near-Newtonian liquid, na liquid in which thevariation
8、of viscosity with shear rate is small and the effect onviscosity of mechanical disturbances such as stirring is negli-gible.3.1.2 Newtonian liquid, na liquid in which the viscosity isindependent of the shear stress or shear rate. If the ratio ofshear stress to shear rate is not constant, the liquid
9、is non-Newtonian.4. Summary of Test Method4.1 The cup is completely immersed in the material to betested, withdrawn, and the time for the material to flow througha hole in the base of the cup is measured.5. Significance and Use5.1 Viscosity is a measure of the fluidity of a material.Viscosity data a
10、re useful in the determination of the ease ofstirring, pumping, dip coating, or other flow-related propertiesof paints and related fluids.5.2 This type of cup is used to measure viscosity because itis easy to use, robust, and may be used in tanks, reservoirs, andreactors.5.3 There are other types of
11、 apparatus for measuring vis-cosity in the laboratory that provide better precision and bias,including the Ford viscosity cup (Test Method D1200), and theBrookfield viscometer (Test Methods D2196).5.4 Certain higher shear rate devices such as cone/plateviscometers (Test Method D4287) provide more in
12、formationabout sprayability, roll coatability, and other high-shear raterelated properties of coatings.6. Apparatus6.1 Zahn Viscosity CupNo. 1 through No. 5 Zahn viscos-ity cups made of corrosion- and solvent-resistant materials.The nominal capacity of the cup is 44 mL, but may vary from43 to 49 mL,
13、 depending on the manufacturer. A diagram of aZahn cup is given in Fig. 1. The dimensions, including orifices,are only approximate because the cups are not made to auniform specification. Each manufacturer produces a different1This test method is under the jurisdiction of ASTM Committee D01 on Paint
14、and Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.24 on Physical Properties of Liquid Paints and Paint Materials.Current edition approved July 1, 2010. Published July 2010. Originally approvedin 1982. Last previous edition approved in 2005 as D4212
15、 99 (2005). DOI:10.1520/D4212-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM Internationa
16、l, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.cup and considerable variation between batches from somemanufacturers has been noted in the past. This is a majorreason why Zahn cups should not be referenced in specifica-tions between producer and user only when
17、 controls sufficientto ensure adequate cup-to-cup and operator-to-operator com-parison are included. (See Appendix X1 for additional infor-mation on Zahn Cups.)NOTE 1The various cup numbers are for identification of the viscosityranges within the series only and should not be used for comparisonbetw
18、een different kinds of cups, that is, a No. 2 Zahn cup has norelationship whatsoever with a No. 2 Shell cup.6.1.1 Nominal Zahn cup orifice diameters are listed in TableX2.1. Cup No. 1 with the smallest orifice is used for determin-ing the viscosity of thin-bodied materials. Cup No. 2 is for usewith
19、clears, lacquers, enamels, and press-side adjustment offlexographic inks; cups Nos. 3 and 4 are for use with moreviscous paints and inks (No. 3 for manufacturing of flexo-graphic inks); and cup No. 5 is used for silk screen inks.6.2 Shell Viscosity Cup3No. 1 through No. 6 Shell vis-cosity cups made
20、of stainless steel with a capacity of 23 mLand a 25-mm (1-in.) long capillary in the bottom and conform-ing to the dimensions shown in Fig. 2.6.2.1 Nominal Shell cup orifice diameters are listed in TableX2.1. Cup Nos. 1 through 212 are recommended for use withreduced rotogravure inks; No. 2 is for u
21、se with flexographic3Shell cups may be obtained from the Norcross Corp., 255 Newtonville Ave.,Newton, MA 02158. This committee is not aware of any other source for flow cupshaving properties similar enough to the Shell cup to be included in this test method.If you have knowledge of a cup that should
22、 be considered, please provide details toASTM International Headquarters. Your comments will receive careful consider-ation at a meeting of the responsible technical committee,1which you may attend.NOTE 1Dimensions are approximate only and may vary with the manufacturer and from batch to batchFIG. 1
23、 Zahn Cup Nominal DimensionsD4212 102inks; Nos. 3 through 4 are used for industrial enamels,lacquers, flexographic, and gravure inks; Nos. 5 and 6 are usedfor heavy materials.6.3 Calibration ThermometerASTM Saybolt ViscosityThermometer 17F having a range of 66 to 80F and subdivi-sions of 0.2F, or 17
24、C having a range of 19 to 27C andsubdivisions of 0.1C, both conforming to the requirements ofSpecification E1. Thermometers having subdivisions otherthan these may be used depending on the sensitivity of thematerial to be tested, the demands of the application, and theagreement between the purchaser
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD42122010STANDARDTESTMETHODFORVISCOSITYBYDIPTYPEVISCOSITYCUPS 粘度 测定 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-516550.html