ASTM D1200-2010(2014) Standard Test Method for Viscosity by Ford Viscosity Cup《采用福特粘度杯的粘度标准试验方法》.pdf
《ASTM D1200-2010(2014) Standard Test Method for Viscosity by Ford Viscosity Cup《采用福特粘度杯的粘度标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1200-2010(2014) Standard Test Method for Viscosity by Ford Viscosity Cup《采用福特粘度杯的粘度标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1200 10 (Reapproved 2014)Standard Test Method forViscosity by Ford Viscosity Cup1This standard is issued under the fixed designation D1200; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This test method covers the determination of the
3、viscos-ity of Newtonian or near-Newtonian paints, varnishes,lacquers, and related liquid materials with the Ford-type effluxviscosity cup. If the material is non-Newtonian, that is,shear-thinning or thixotropic, Test Method D2196 should beused.1.2 The values stated in SI units are to be regarded as
4、thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the
5、applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D2196 Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational (Brookfield type)ViscometerE1 Specification for ASTM Liquid-in-Glass Thermometers3. Terminology3.1 Definitions:3.1.1
6、 Newtonian liquid, na liquid in which the viscosity isindependent of the shear stress or shear rate. If the ratio ofshear stress to shear rate is not constant, the liquid is non-Newtonian.3.1.2 Near-Newtonian liquid, na liquid in which thevariation of viscosity with shear rate is small and the effec
7、t onviscosity of mechanical disturbances such as stirring is negli-gible.4. Summary of Test Method4.1 The Ford viscosity cup is filled level full with the liquidunder test, and the time for the material to flow through one ofthe standard orifices is measured.5. Significance and Use5.1 This test meth
8、od is useful for the determination ofpackage and application viscosities of a number of paints andother coatings and in the thinning of these materials, but islimited to Newtonian or near-Newtonian liquids.5.2 There are other types of apparatus for measuring vis-cosity in the laboratory that produce
9、 more accurate results.6. Apparatus6.1 Ford Viscosity CupsNos. 1, 2, 3, 4, and 5 Fordviscosity cups made of corrosion- and solvent-resistant mate-rials assembled as complete units (Note 1), and conforming tothe dimensional requirements shown in Fig. 1. The orificedimensions are considered as a guide
10、 only as the combinationof cup and orifice dimensions must permit conformance to theflow formula for each cup as listed in the Appendix.NOTE 1If the orifice is removed from the cup for any reason the cupshould be recalibrated before use as described in the Appendix.6.2 ThermometerSaybolt Viscosity T
11、hermometer con-forming to the requirements forThermometer 17C (19 to 27C)or 17F (66 to 80F) as prescribed in Specification E1.Inaddition, temperature measuring devices such as non-mercuryliquid-in-glass thermometers, thermocouples, or platinum re-sistance thermometers that provide equivalent or bett
12、er accu-racy and precision, that cover the temperature range forthermometer 17C and 17F, may be used.6.3 Timing DeviceAny timing device may be used pro-viding that the readings can be taken with a discrimination of0.2 s or better.7. Test Specimen7.1 The specimen of the material to be tested shall be
13、 visiblyhomogeneous and free of any foreign material or air bubbles.8. Temperature of Testing8.1 All measurements with the Ford viscosity cups shall bemade at 25C (77F) or a temperature agreed upon between1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings,
14、 Materials, andApplications and is the direct responsibility ofSubcommittee D01.24 on Physical Properties of Liquid Paints and Paint Materials.Current edition approved Dec. 1, 2014. Published December 2014. Originallyapproved in 1952. Last previous edition approved in 2010 as D1200 10. DOI:10.1520/D
15、1200-10R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Driv
16、e, PO Box C700, West Conshohocken, PA 19428-2959. United States1producer and user. Temperature drift during the test should bekept to a minimum and should not exceed 60.2C (60.4F).NOTE 2 It is impossible to predict the effect of temperature change oneach material with which the apparatus may be used
17、. This factor may beless than 1 % per degree Celsius for some liquids whereas others may beas high as 8 to 10 % per degree Celsius.9. Calibration9.1 Cups should be calibrated in accordance with theprocedure described in Appendix X1. The frequency of thiscalibration check depends upon the amount of u
18、se and the carethat the individual cup receives. If the cup varies more than10 % from standard, it should not be used.10. Conditioning10.1 Bring the material to a temperature a few degreesbelow that desired and then agitate vigorously for 10 min on areciprocating shaker in a pint can two-thirds full
19、. Allow tostand undisturbed for 10 min while adjusting further to thedesired temperature. Make the viscosity determination at theend of the 10-min period.11. Procedure11.1 Make viscosity determinations in a room free of draftsand rapid changes in temperature. For the highest degree ofprecision the r
20、oom temperature should be between 22 and28C (72 and 82F). Determinations should be made at atemperature above the dew point of the atmosphere surround-ing the apparatus.11.2 Choose the proper cup so that the time of efflux will bebetween 20 and 100 s (preferably between 30 and 100 s) forcup Nos. 3,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD120020102014STANDARDTESTMETHODFORVISCOSITYBYFORDVISCOSITYCUP 采用 福特 粘度 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-509435.html