1、Designation: D 3698 04Standard Practice forSolvent Vapor Degreasing Operations1This standard is issued under the fixed designation D 3698; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in paren
2、theses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice recommends work practices for conven-tional vapor degreasing operations utilizing any solvent orsolvent blend that has been categorized
3、 as nonflammable.1.2 This practice is not intended for use in vapor degreasingoperations utilizing flammable (low flash point) solvents or invapor degreasing operations utilizing enclosed (sealed, air-tight) equipment. For these non-applicable operations, usersshould consult the solvent or equipment
4、 supplier for additionalinformation.1.3 The values given in inch-pound units are to be regardedas the standard. The values stated in parentheses are forinformation only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility o
5、f the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D2110 Test Method for pH of Water Extractions of Halo-genated Organic Solvents and Their AdmixturesD 29
6、42 Test Method for Total Acid Acceptance of Haloge-nated Organic Solvents (Nonreflux Methods)D 4276 Practice for Confined Area EntryD 4579 Practice for Handling an Acid Degreaser or Still2.2 Government Documents:340 CFR Part 63.460-469 U.S. EPA, National EmissionStandards for Halogenated Solvent Cle
7、aning29 CFR Part 1910 U.S. Department of Labor, OccupationalSafety and Health Standards2.3 Other Documents:Threshold Limit Values for Chemical Substances and Physi-cal Agents, ACGIH Industrial Ventilation, ACGIH4NFPA 704 Identification System for Fire Hazards of Mate-rials, National Fire Protection
8、Association53. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 emergencyany occurrence that may result in animmediate hazard to health including exposures resulting from,but not limited to, equipment failure, rupture of containers, orfailure to control equipment.3.1.2 hazardous o
9、perationany procedure or activitywhere a release of the solvent or the decomposition products ofthe solvents might be expected to result in a hazard to health.3.1.3 nonflammable solvent(s)as used herein, is a solventor solvent mixture having a NFPA flammability hazard ratingof 1 or lower (as determi
10、ned by NFPA 704), intended for use invapor degreasing operations.3.1.4 solvent vapor degreasera solvent and corrosion-resistant tank with a heated solvent reservoir or sump at thebottom, a condensing means near the top, and freeboard abovethe condensing means, in which sufficient heat is introduced
11、toboil the solvent and generate hot solvent vapor. Because the hotvapor is heavier than air, it displaces the air and fills the tankup to the condensing zone. The hot vapor condenses on thecooled condensing means, thus maintaining a fixed vapor leveland creating a thermal balance.3.1.5 solvent vapor
12、 degreasing operationsthe process bywhich materials are immersed in vapors of boiling liquids forthe purpose of cleaning or altering their surfaces, and aresubsequently removed from the vapors, drained and dried in asolvent vapor degreaser.4. Significance and Use4.1 This practice is intended for use
13、 by employers indeveloping their own specific operation standards for solventvapor degreasing operations.1This practice is under the jurisdiction of ASTM Committee D26 on Haloge-nated Organic Solvents and Fire Extinguishing Agents and is the direct responsi-bility of Subcommittee D26.02 on Vapor Deg
14、reasing.Current edition approved Dec. 1, 2004. Published December 2004. Originallyapproved in 1979. Last previous edition approved in 1999 as D 3698 99.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMSta
15、ndards volume information, refer to the standards Document Summary page onthe ASTM website.3Code of Federal Regulations, available from U.S. Government Printing Office,Washington, DC 20402.4Available from American Conference of Governmental Industrial Hygienists,Inc., 1330 Kemper Meadow Dr., Suite 6
16、00, Cincinnati, OH 45240.5Available from National Fire Protection Association, 1 Batterymarch Park,Quincy, MA 022699101.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2 Certain vapor degreasing operations are subject to therequire
17、ments of the National Emission Standards for Haloge-nated Solvent Cleaning (Halogenated Solvent Cleaner NES-HAP) as found in 40 CFR Part 63, Subpart T. The determina-tion of the applicability of these, or any additionalrequirements is the responsibility of the user.4.3 This practice is not intended
18、to address all of therequirements contained in the Halogenated Solvent CleanerNESHAP. Development and implementation of training pro-grams, recordkeeping, and other additional requirements of theNESHAP are the responsibility of the user.5. Exposure Limit5.1 No employee may be exposed to any of the s
19、olventsutilized in vapor degreasing operations covered by this sectionin excess of either the OSHA Permissible Exposure Limits(PEL), the ACGIH Threshold Limit Value (TLVt), or anymanufacturers recommended exposure limit.6. System Location and Design6.1 Location:6.1.1 Degreasers shall be placed in a
20、room having ventila-tion adequate to maintain operator exposure below the appro-priate exposure limit.6.1.2 A degreaser shall be installed so that it is not affectedby drafts from sources such as windows, doors, fans, unitheaters, ventilators, or adjacent spray booths. Normal aircirculation (at velo
21、cities not exceeding 50 ft (15.24 m)/min) isrecommended and should not be confused with direct draftssuch as those listed in the preceding sentence. Drafts should bediverted from the top of the degreaser by the use of baffleslocated on the windward side of the degreaser.6.1.3 No degreaser shall be i
22、nstalled in areas where solventvapors may reach open flames or high-temperature surfacesabove 350F (176C). Solvent degreasing equipment shall notbe installed in the proximity of welding and heat treatingoperations or space heaters unless adequate ventilation of thedegreaser or other means are provid
23、ed to prevent solvent fumesfrom contacting the high-temperature source.6.1.4 Gas-heated degreasers (provided with natural draftventilation of combustion tube) shall not be located in an areawhere the general mechanical exhaust system produces nega-tive pressure, unless positive exhausting of combust
24、ion prod-ucts by mechanical means is provided.6.2 Design:6.2.1 The level of vapors below the top edge of thedegreaser (freeboard) shall at a minimum be a 1.0 ratio ofheight to width.6.2.2 All degreasers shall have durable covers which shallbe secured in a closed position when degreasing operations a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD36982004STANDARDPRACTICEFORSOLVENTVAPORDEGREASINGOPERATIONS 溶剂 蒸气 脱脂 操作方法 标准 规程 PDF

链接地址:http://www.mydoc123.com/p-515288.html