ASTM D2220-2017 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable 75&xb0 C Operation《工作温度为75 ℃的电线和电缆用聚氯乙烯绝缘材料的标准规格》.pdf
《ASTM D2220-2017 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable 75&xb0 C Operation《工作温度为75 ℃的电线和电缆用聚氯乙烯绝缘材料的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2220-2017 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable 75&xb0 C Operation《工作温度为75 ℃的电线和电缆用聚氯乙烯绝缘材料的标准规格》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2220 17Standard Specification forPoly(Vinyl Chloride) Insulation for Wire and Cable, 75COperation1This standard is issued under the fixed designation D2220; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers a thermoplastic insulation ofpoly(vinyl chloride) or the copolymer of vinyl chloride andvin
3、yl acetate.1.2 This insulation is recommended for use in power andcontrol circuits at temperatures not higher than 75C. At athickness of 15 mils (0.38 mm), application is limited tovoltage ratings below 300 V, and to dry locations. At athickness of 30 mils, the application range is widened to dry or
4、wet applications, and to a voltage rating of 600 V.1.3 In many instances the insulation material cannot betested unless it has been formed around a conductor or cable.Therefore, tests are done on insulated wire or cable in thisspecification solely to determine the relevant property of theinsulation
5、material and not to test the conductor or completedcable.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4.1 In come cases (includi
6、ng the title), temperatures aredescribed in degrees Celsius only.2. Referenced Documents2.1 ASTM Standards:2D1711 Terminology Relating to Electrical InsulationD2633 Test Methods for Thermoplastic Insulations andJackets for Wire and CableD2633 Test Methods for Thermoplastic Insulations andJackets for
7、 Wire and CableG153 Practice for Operating Enclosed Carbon Arc LightApparatus for Exposure of Nonmetallic MaterialsG155 Practice for Operating Xenon Arc Light Apparatus forExposure of Non-Metallic Materials3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this specification, refer
8、to Terminology D1711.3.2 Definitions of Terms Specific to This Standard:3.2.1 aging (act of), nexposure of materials to air or oil ata temperature and a time as specified in Table 1.4. Physical Properties4.1 The insulation shall conform to the requirements forphysical properties prescribed in Table
9、1.5. Electrical Requirements5.1 Perform the ac voltage, insulation resistance, and dcvoltage tests in that order when any of these tests are required.The sequence for other testing is not specified.5.2 AC Voltage TestTest the insulated conductor at the acwithstand voltage as specified in Table 2. Un
10、less otherwisespecified, omit this test if the dc withstand voltage testdescribed in 5.4 is performed.5.2.1 For cables or conditions of service where mechanicalstresses govern, such as in submarine cables or long verticalrisers, it is possible that the minimum conductor sizes in Table2 are not stron
11、g enough.5.2.2 The thicknesses given in Table 2 apply to aerial cablesand to single conductors installed in conduits above ground andto the individual conductors of all multiple-conductor cableshaving a common jacket metallic sheath or protective coveringover the assembly, except as shown in 5.2.2.1
12、.5.2.2.1 For single-conductor cables for installation in under-ground ducts or direct earth burial, add 15 mils (0.38 mm) tothe insulation thicknesses given in Table 2 when such cables donot have a thermoplastic jacket or metallic sheath over theassembly.5.2.3 Where the thickness of the insulation i
13、s increased formechanical reasons or for special service conditions, determinethe test voltage in Table 2 by the size of the conductor and therated voltage.5.3 Insulation Resistance:1This specification is under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials a
14、nd is the direct responsibility ofSubcommittee D09.07 on Electrical Insulating Materials.Current edition approved March 1, 2017. Published March 2017. Originallyapproved in 1963. Last previous edition approved in 2011 as D2220 11. DOI:10.1520/D2220-17.2For referenced ASTM standards, visit the ASTM w
15、ebsite, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbo
16、r Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendatio
17、ns issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.15.3.1 Insulated conductors in sizes AWG 14 (2.08 mm2) andlarger shall have an insulation resistance of at least thatcorresponding to a constant of 2000 M -1000 ft at 60F(15.6C).5.3.2 If the temperature at the time
18、 measurement was madediffers from 60F (15.6C), correct the insulation resistance to60F by multiplying the measured value by the proper correc-tion factor from Table 1, Temperature Correction Factors forInsulation Resistance at 60F, of Methods D2633.5.4 DC Voltage TestUpon completion of the insulatio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD22202017STANDARDSPECIFICATIONFORPOLYVINYLCHLORIDEINSULATIONFORWIREANDCABLE75XB0COPERATION 工作温度 75

链接地址:http://www.mydoc123.com/p-511229.html