ASTM C739-2005be1 Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation《纤维素纤维松填保温层标准规范》.pdf
《ASTM C739-2005be1 Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation《纤维素纤维松填保温层标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C739-2005be1 Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation《纤维素纤维松填保温层标准规范》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 739 05be1Standard Specification forCellulosic Fiber Loose-Fill Thermal Insulation1This standard is issued under the fixed designation C 739; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.e1NOTETable 3 was editorially corrected in May 2007.1. Scope1.1
3、 This specification covers the composition and physicalrequirements of chemically treated, recycled cellulosic fiberloose-fill type thermal insulation for use in attics or enclosedspaces in housing, and other framed buildings within theambient temperature range from 45 to 90C (49 to 194F)by pneumati
4、c or pouring application. While products thatcomply with this specification are used in various construc-tions, they are adaptable primarily, but not exclusively, to woodjoist, rafters, and stud construction.1.2 The values stated in SI units are to be regarded as thestandard. The values in parenthes
5、es are provided for informa-tion only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory li
6、mitations prior to use.2. Referenced Documents2.1 ASTM Standards:2B 152 Specification for Copper Sheet, Strip, Plate, andRolled BarC 168 Terminology Relating to Thermal InsulationC 177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot
7、-Plate ApparatusC 518 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Heat Flow Meter ApparatusC 687 Practice for Determination of Thermal Resistance ofLoose-Fill Building InsulationC 1045 Practice for Calculating Thermal TransmissionProperties
8、 from Steady-State ConditionsC 1114 Test Method for Steady-State Thermal TransmissionProperties by Means of the Thin-Heater ApparatusC 1374 Test Method for Determination of Installed Thick-ness of Pneumatically Applied Loose-Fill Building Insula-tionC 1363 Test Method for Thermal Performance of Buil
9、dingMaterials and Envelope Assemblies by Means of a HotBox ApparatusC 1485 Test Method for Critical Radiant Flux of ExposedAttic Floor Insulation Using an Electric Radiant HeatEnergy SourceE 970 Test Method for Critical Radiant Flux of ExposedAttic Floor Insulation Using a Radiant Heat Energy Source
10、3. Terminology3.1 DefinitionsFor definitions of terms used in this speci-fication, see Terminology C 168.3.2 Definitions of Terms Specific to This Standard:3.2.1 attican enclosed space between the roof and ceilingof the occupied part of a building.3.2.2 critical radiant fluxthe level of incident rad
11、iant heatenergy on the attic floor insulation system at the most distantflame-out point (W/cm2(Btu/ft2 s).4. Materials and Manufacture4.1 The basic material shall be recycled cellulosic fibermade from selected paper, paperboard stock, or ground woodstock, excluding contaminated materials, which may
12、reason-ably be expected to be retained in the finished product. Suitablechemicals are introduced to provide properties such as flameresistance, processing, and handling characteristics.4.2 The basic material may be processed into a formsuitable for installation by pneumatic or pouring methods.1This
13、specification is under the jurisdiction of ASTM Committee C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.23 onBlanket and Loose Fill Insulation.Current edition approved Nov. 15, 2005. Published December 2005. Originallyapproved 1973. Last previous edition approved 2005
14、 C 739 05a.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Dri
15、ve, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Physical and Chemical Properties5.1 Design DensityThe design density shall be deter-mined in accordance with Section 8. Report all units in kg/m3(lb/ft3).5.1.1 Design density is not a basis for acceptance orrejection.5.2 Corrosivene
16、ssThe loose-fill insulation material shallbe tested for corrosiveness as specified in Section 9. Thecomposition of the insulation material shall be such that aftertesting, no perforation of the 3-mil (76-m) metal specimensshall be evident when the specimens are observed over a 40-Wappliance light bu
17、lb. Notches extending into the coupon 3 mmor less from any edge shall be ignored.5.3 Critical Radiant FluxWhen tested in accordance withSection 10, the critical radiant flux shall be equal to greaterthan 0.12 W/cm2(0.11 Btu/ft2 s). All values shall be reportedto two significant digits.5.4 Fungi Resi
18、stanceThe loose-fill insulation materialshall be tested and shall pass fungi resistance as specified inSection 11. If the growth on two or more of the replicate testitems is greater than that on the comparative item, the test itemshall be considered to fail.NOTE 1If the manufacturing claims the insu
19、lation kills or controlsinsects or rodents, or both, the product must be registered as a pesticideunder the Federal Insecticide, Fungicide and Rodentic Act, as amended,and must also be registered in accordance with state pesticide statutes.5.5 Moisture Vapor SorptionMoisture gain in the insula-tion
20、shall be no more than 15 % by weight when tested inaccordance with Section 12.5.6 Odor EmissionAny sample producing a detectableodor that is classified as objectionable and strong or very strongby more than two panel members shall be considered to havefailed the test when tested in accordance with S
21、ection 13.5.7 Smoldering CombustionWhen tested in accordancewith the smoldering combustion test method in Section 14, theinsulation shall show no evidence of flaming and a weight lossno greater than 15 %.5.8 Thermal ResistanceThe standard thermal resistancevalues normally recommended for open applic
22、ation are: 2.3,3.4., 3.9, 5.3, 6.7, and 8.6 (13, 19, 22, 30, 38 and 49) and areexpressed in Km2/W (Fhft2/Btu). The thermal resistance Rfor the average of any (four) randomly selected specimens shallnot be more than 5 % below the listed R value when tested inaccordance with Section 15. R values other
23、 than those listedshall be as agreed upon between the supplier and the purchaser.6. Workmanship, Finish, and Appearance6.1 The product shall be free of extraneous foreign materialssuch as metals and glass that will adversely affect the perfor-mance in service.TEST METHODS7. Summary7.1 The following
24、tests shall be conducted on loose-fillcellulosic insulation at the measured design density: moisturevapor sorption, smoldering combustion, and thermal resis-tance.NOTE 2The importance of an insulations product to maintain its fireretardant characteristics is recognized. A task group in ASTM C16.31 i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC7392005BE1STANDARDSPECIFICATIONFORCELLULOSICFIBERLOOSEFILLTHERMALINSULATION 纤维素 纤维 保温 标准规范 PDF

链接地址:http://www.mydoc123.com/p-508178.html