1、Designation: C 412 05aStandard Specification forConcrete Drain Tile1This standard is issued under the fixed designation C 412; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indic
2、ates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers concrete drain tile with inter-nal diameters from 4 to
3、 36 in. that are intended to be used forsurface and subsurface drainage.1.2 A complete metric companion to Specification C 412has been developedC 412M; therefore, no metric equivalentsare presented in this specification.NOTE 1This specification is a manufacturing and purchase specifica-tion only and
4、 does not include requirements for bedding, backfill, or therelationship between field load condition and the strength classification ofdrain tile. However, experience has shown that the successful performanceof the product depends upon the proper selection of the class of drain tile,type of bedding
5、 and backfill, and care that the installation conforms to theconstruction specifications. The owner is cautioned that he must correlatethe field requirements with the class of drain tile specified and provide foror require inspection at the construction site.2. Referenced Documents2.1 ASTM Standards
6、:2C33 Specification for Concrete AggregatesC 150 Specification for Portland CementC 497 Test Methods for Concrete Pipe, Manhole Sections,or TileC 595 Specification for Blended Hydraulic CementsC 618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC 822 Terminolo
7、gy Relating to Concrete Pipe and RelatedProductsC 989 Specification for Ground Granulated Blast-FurnaceSlag for Use in Concrete and MortarsC 1116 Specification for Fiber-Reinforced Concrete andShotcrete3. Terminology3.1 DefinitionsFor definitions of terms relating to con-crete pipe, see Terminology
8、C 822.4. Classification4.1 Drain tile manufactured according to this specificationshall be of the following four classes:4.1.1 Standard-Quality Concrete Drain Tile, intended forland drainage of ordinary soils where the tile are laid intrenches of moderate depths and widths. Standard-Qualityconcrete
9、drain tile are not recommended for use where internaldiameters in excess of 12 in. are required.4.1.2 Extra-Quality Concrete Drain Tile, intended for landdrainage of ordinary soils where the tile are laid in trenches ofconsiderable depths or widths, or both.4.1.3 Heavy-Duty Extra-Quality Concrete Dr
10、ain Tile, in-tended for land drainage of ordinary soils where the tile are laidin trenches of large depths or widths, or both.4.1.4 Special-Quality Concrete Drain Tile, intended for landdrainage where special precautions are necessary for concretetile laid in soils that are markedly acid or contain
11、unusualquantities of sulfates (see Section 7), and where the tile are laidin trenches of considerable depths or widths, or both.4.1.4.1 Where the calculated loads are in excess of thecrushing strengths prescribed in the physical requirements forextra-quality and special-quality concrete drain tile,
12、tilestrengths must be specified in advance by the owner.5. Basis of Acceptance5.1 The acceptability of drain tile shall be determined by (1)the results of the physical tests as specified in Section 8, and inTest Methods C 497,(2) measurements and inspection toascertain whether the tile conform to th
13、e requirements regard-ing dimensions, shape, and freedom from visible defects, and(3) the manufacturers certification in writing that the tile havebeen made in accordance with any special provisions, such asstrength, absorption, permeability, type of cement, admixture,curing conditions, etc.5.2 The
14、owner shall specify in writing the class or classes ofconcrete tile to be supplied, whether Standard-Quality, Extra-Quality, Heavy-Duty Extra-Quality, or Special-Quality. Unless1This specification is under the jurisdiction of ASTM Committee C13 onConcrete Pipe and is the direct responsibility of Sub
15、committee C13.01 onNon-Reinforced Concrete Sewer, Drain, and Irrigation Pipe.Current edition approved Dec. 1, 2005. Published January 2006. Originallyapproved in 1958. Last previous edition approved in 2005 as C 412 05.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact A
16、STM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Extra-Quality, Heavy-Duty E
17、xtra-Quality, or Special-Qualityconcrete drain tile have been specified, Standard-Quality draintile shall be accepted.6. Materials6.1 ConcreteThe concrete shall consist of cementitiousmaterials, mineral aggregates, and water.6.2 Cementitious Materials:6.2.1 CementCement shall conform to the requirem
18、entsfor portland cement of Specification C 150, or shall be portlandblast-furnace slag cement, slag-modified portland cement, orportland-pozzolan cement conforming to the requirements ofSpecification C 595. except that the pozzolan constituent in theType IP portland-pozzolan cement shall be fly ash.
19、6.2.2 Fly AshFly ash shall conform to the requirements ofClass F or Class C of Specification C 618.6.2.3 Ground Granulated Blast Furnace Slag (GGBFS)GGBFS shall conform to the requirements of Grade 100 or 120of Specification C 989.6.2.4 Allowable Combinations of Cementitious MaterialsThe combination
20、 of cementitious materials used in the concreteshall be one of the following:6.2.4.1 Portland cement only,6.2.4.2 Portland blast furnace slag cement only,6.2.4.3 Slag modified portland cement only,6.2.4.4 Portland pozzolan cement only,6.2.4.5 A combination of portland cement and fly ash,6.2.4.6 A co
21、mbination of portland cement and groundgranulated blast-furnace slag, or6.2.4.7 A combination of portland cement, fly ash (not toexceed 25 % of the total cementitious weight) and groundgranulated blast furnace slag (not to exceed 25 % of the totalcementitious weight).6.3 AggregatesAggregates shall c
22、onform to SpecificationC33, except that the requirements for gradation shall notapply.6.4 Admixtures and BlendsAdmixtures and blends shallonly be used with the approval of the owner.6.5 Synthetic FibersAt the manufacturers option, col-lated fibrillated virgin polypropylene fibers are not prohibitedf
23、rom being used as a nonstructural manufacturing material.Only Type III synthetic fibers designed and manufacturedspecifically for use in concrete and conforming to the require-ments of Specification C 1116 shall be used.7. Chemical Requirements7.1 Acid and Sulfate Resistance:7.1.1 The owner is not p
24、rohibited from specifying specialrequirements in order to increase the durability of the drain tilein cases where the soils, soil waters, or drainage waters aremarkedly acid or contain moderate or severe quantities of soilsulfates. Without a specific agreement in advance, no drain tileshall be rejec
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC4122005ASTANDARDSPECIFICATIONFORCONCRETEDRAINTILE 混凝土 排水 标准规范 PDF

链接地址:http://www.mydoc123.com/p-466512.html