1、Designation: C410 10Standard Specification forIndustrial Floor Brick1This standard is issued under the fixed designation C410; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indic
2、ates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers brick made from clay or shaleor mixtures thereof and are suitable for surfacing industrialfloors. Ceramic shapes known as quarry tile a
3、re not covered bythis specification. Four types of industrial floor brick arecovered (Note 1):1.1.1 Type TFor use where a high degree of resistance tothermal and mechanical shock is required but low absorption isnot required.1.1.2 Type HFor use where resistance to chemicals andthermal shock are serv
4、ice factors but low absorption is notrequired.1.1.3 Type MFor use where low absorption is required.Brick of this type are normally characterized by limitedmechanical (impact) shock resistance but are often highlyresistant to abrasion.1.1.4 Type LFor use where minimal absorption and a highdegree of c
5、hemical resistance are required. Brick of this typeare normally characterized by very limited thermal and limitedmechanical (impact) shock resistance but are highly resistant toabrasion.NOTE 1Discussion of Types of Floor BrickThe four types of brickincluded in this specification are designed to cove
6、r the diverse needs ofmany industries for floor units. Recognizing that the requirements ofprimary aluminum producers are quite different from those of chemicalmanufacturers, and similarly, that the need of a builder for brick withwhich to pave an airport terminal building may vary considerably from
7、those of food processing plants, for example, a minimum of four bricktypes has been deemed necessary. The factors of modulus of rupture,water absorption, and chemical resistance have been selected as the basisfor the classification system.1.2 Terminology related to industrial floor brick is found in
8、Terminology C1232.1.3 UnitsThe values stated in inch-pound units are to beregarded as standard. The values given in parentheses aremathematical conversions to SI units that are provided forinformation only and are not considered standard.2. Referenced Documents2.1 ASTM Standards:2C67 Test Methods fo
9、r Sampling and Testing Brick andStructural Clay TileC279 Specification for Chemical-Resistant Masonry UnitsC1232 Terminology of Masonry3. Physical Properties3.1 Brick shall conform to the physical requirements for thetype specified as prescribed in Table 1.4. Sizes4.1 The sizes of brick shall be as
10、specified by the purchaser.The maximum permissible variations in dimensions of indi-vidual units shall not exceed those given in Table 2.5. Warpage5.1 Tolerances for deviation of face or edges of individualbrick from a plane surface and from a straight line, respec-tively, shall not exceed the maxim
11、um values specified in Table3.6. Texture6.1 The texture of the finished surface that will be exposedwhen in place shall conform to an approved sample consistingof not less than four bricks, each representing the texturedesired.7. Sampling and Testing7.1 The brick shall be sampled and tested for modu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC4102010STANDARDSPECIFICATIONFORINDUSTRIALFLOORBRICK 工业 铺地砖 标准规范 PDF

链接地址:http://www.mydoc123.com/p-466505.html